Element
Type
Description
Current Value
Text
Shows which device that is receiver for the wake up report and the
current and default wake up interval.
Read Value From Device
Button
Button to read current value from the device.
New Value
Read only text,
Option Menu
Option menu to select new wake up interval in seconds. Receiver device
is always the SmartBox (Device 1).
Write Value To Device
Button
Button to write a new value to the device.
Back
Button
Button to go back to Z-Wave Network page
4.2.2.6
Advanced
Even if the configuration parameters are not defined in the device database you will still be able to
configuring the device using a
generic
interface, see below. It is very important that you read the Z-
Wave device manual carefully to understand which parameters that is valid.
Element
Type
Description
Parameter Number
Option Menu
Parameter number 1 to 255
Current Value
Number
Shows current value of the parameter. Use button Read Value From
Device to read this value from the device
Read Value from Device
Button
Request current parameter value from device
New Value
Option Menu
Value Select Box
Fields to enter a new parameter value.
Parameter length: 1, 2 or 4 bytes
Value: 0 to a max value dependent of the parameter length.
Save the value with Write Value to Device
Write Value To Device
Button
Button to write a new parameter value to the device.
Back
Button
Button to go back to Z-Wave Network page