Conditions are logically combined with AND or OR. You can reorder or remove conditions by using
the buttons to the right of the conditions.
5.1.7
Scene Actions
Action Type
Action Operator
Action Value/Parameter
Delay
-
HH:MM:SS
Actuator
set to
Off, On
Alarm Output
set to
Off, On
KNX (DPT1)
set to
0, 1
KNX (DPT2)
disable priority and set value to,
enable priority and set value to
0, 1
KNX (DPT3)
decrease dimming and set step code to,
increase dimming and set step code to
Value (Step Code)
KNX (DPT5, DPT9, DPT12, DPT13,
DPT14)
set to
Value
KNX (DPT18)
activate scene number
1 – 64 (Scene number)
Notification
-
Notification subject and message
System (Automation Mode)
set to
Home, Away, Night, Vacation
System (Global variable)
set to
Value
You can reorder or remove actions by using the buttons to the right of the actions.
NOTE! If the scene is retriggered during execution of the scene actions, the activity will restart
again from first action.
Tip! You can activate another scene from a scene by using a global variable as action in first scene