CDD3000-HF Operation Manual
4-13
4 Commissioning
DE
EN
FR
IT
ES
FR
For more information on setting up user-defined encoders and on
automatic track signal correction refer to the CDD3000 Application
Manual.
Checking the encoder
To check the encoder the motor shaft is rotated by hand. The viewing
angle when checking is from the front onto the shaft end (flange). The
“CDD3000-HF reference and actual values” status display, under “nist,
Actual speed”, must indicate a positive speed in clockwise rotation and a
negative speed in counter-clockwise rotation. If the speed is incorrect, the
following points must be checked (see also section 3.3.4):
•
Is the encoder cable correctly connected to the motor and the
CDD3000-HF ?
•
Is the encoder cable in use the correct one for the type of encoder ?
4.3.4 Making basic
settings
Custom setup screens are provided for fine adjustment of each preset
solution. You can use them to adapt the drive to your application. For a
detailed description of the individual functions refer to the CDD3000
Application Manual.