CDD3000-HF Operation Manual
2-7
2 Mechanical installation
DE
EN
FR
IT
ES
FR
Note the following points:
•
Cooling can be attained either by a sufficiently large
backing plate (see Table 2.3) or by an additional cooler.
The cooler must be mounted centrally behind the
hottest area (1) of the device. See also “Project
planning notes, “Cold plate”” in Appendix A.3.
•
The temperature on the rear panel of the drive
controller for highspeed drives must not exceed 85.0 °C. At a
temperature > 85 °C the device shuts down automatically. It can
only be restarted when it has cooled.
•
Required evenness of contact surface = 0.05 mm, maximum
roughness of contact surface = roughness factor 6.3
(1)
Size
Device rated
power
drive controller for
highspeed drives
P
V
[W]
at 4/
8-16 kHz
R
thK
3)
[K/W]
Backing plate (unvarnished
steel min. cooling area
Ambient
temperature
BG1
1.0 kVA
CDD32.003-HF,Cx.x
49 / 52 W
0.05
None
45°C
1.6 kVA
CDD32.004-HF,Cx.x
63 / 70 W
0.05
650x100mm = 0.065m²
45°C
1)
, 40°C
2)
BG2
2.2 kVA
CDD32.006-HF,Cx.x
90 / 97 W
0.05
650x460mm = 0.3m²
45°C
1)
, 40°C
2)
2.8 kVA
CDD32.008-HF,Cx.x
110 / 120 W
0.05
650x460mm = 0.3m²
45°C
1)
, 40°C
2)
1.5 kVA
CDD34.003-HF,Cx.x
70 / 85 W
0.05
None
45°C
1)
, 40°C
2)
2.8 kVA
CDD34.005-HF,Cx.x
95 / 127 W
0.05
650x460mm = 0.3m²
45°C
1)
, 40°C
2)
3.9 kVA
CDD34.006-HF,Cx.x
121 / 163 W
0.05
An additional cooler is required to supply
adequate cooling.
For project planning notes see Appendix A.3.
BG3
5.4 kVA
CDD34.008-HF,Cx.x
150 / 177 W
0.03
6.9 kVA
CDD34.010-HF,Cx.x
187 / 222 W
0.03
BG4
9.7 kVA
CDD34.014-HF,Cx.x
225 / 283 W
0.02
11.8 kVA
CDD34.017-HF,Cx.x
270 / 340 W
0.02
BG5
16.6 kVA
CDD34.024-HF,Cx.x
330 / 415 W
0.015
22.2 kVA
CDD34.032-HF,Cx.x
415 / 525 W
0.015
1) With a power stage clock frequency of 4 kHz
2) With a power stage clock frequency of 8/12/16 kHz
3) Thermal resistance between active cooling area and cooler
Table 2.3
Required cooling with cold plate
Note the following points:
•
The backing plate must be grounded over a large area.
•
The best result for effective EMC installation is attained with a
chromated or galvanized backing plate. If backing plates are
varnished, the coating must be removed in the area of the contact
surface!