2-20
2.4.7 L
UST
B
US
connection (Design C9/ C12)
C9 design:
The VF1000 Series M inverters in this design have a potential-free interface
connection RS485. The inverters can be operated via this interface
according to the L
UST
B
US
data transmission protocol.
Terminal assignment see Fig.:
An external 24 V DC supply (V
DD
)
is necessary to operate the
interface.
Technical data:
Des.
RS485
Voltage supply ext.
V
DD
24 VDC ±15%
Current intake
I
approx. 50 mA
Isolation
-
corresponds to VDE 0884, Protective low voltage
Driver power
-
RS485: 31 participants, removal < 1000 m
Bus termination
-
not installed
Transmission rate
-
fixed 9600 Baud
C12 design:
The VF1000 Series M inverters
in this design have a potential-
free interface connection
RS232. The inverters can be
operated via this interface
according to the L
UST
B
US
data
transmission protocol.
Terminal assignment see Fig.:
An external power supply is not
necessary for the operation of
the interface.
+
29
36
34
35
47
48
49
50
51
52
-
+
SOUTA
V
DD
GND
A
B
RS485*
KP100
PTC *
X5
X4
X3
X2
46
n.c.
23
29
36
47
48
49
50
51
52
-
+
SOUTA
SOUTF
GND
TxD
RxD
RS232*
KP100
PTC *
100
X5
X4
X3