4-6
4.3.2 MOP function with K
EY
P
AD
KP100
Once pass word is confirmed the control
terminal is blocked. Preset frequency
reference (K
EY
P
AD
) is e.g. 10 Hz. Start inverter
by pressing the start/enter-key.
Actual value (small display) and clockwise
rotation are additionally displayed.
Raise the speed reference to 50 Hz for
example with the arrow key.
Inverter follows the increase with acceleration
ramp.
Reduce speed reference with arrow keys.
Inverter follows the reduction with the braking
ramp. With < 0.0 Hz the inverter changes the
direction of the rotary field.
Increase speed reference (counter-clockwise)
to 10 Hz for example.
In addition sign (--) indicates counter-
clockwise.
Press stop/return-key, inverter brakes the
motor to stand still.
The MOP function is reactivated with the start/
enter-key.
CTRL
CTRL
Hz
CTRL
Hz
s t a r t
e n t e r
CTRL
Hz
CTRL
Hz
s t o p
r e t u r n
from Overview
CTRL-Menu
to overview
CTRL-Menu