background image

1

Lutron Athena System User Guide

Purpose of this document

 This document will be updated frequently as new features and capabilities are added to the Athena system.

•  Summarize what the Athena app / system can do

•  Explain Operations & Maintenance

What is an Athena System

Overview

Athena is a flexible, simple, all-in-one solution that combines the world’s most advanced light source with 

intelligent shades and connected apps to deliver a holistic light experience.
The most up-to-date information about the system can be found on our website:  

https://www.lutron.com/en-US/Products/Pages/WholeBuildingSystems/athena/overview.aspx
For further system architecture and device details see:  

https://www.lutron.com/TechnicalDocumentLibrary/3685737_Athena_System_Architecture.pdf
Athena is an evolving solution that like other modern software solutions, when Internet connected, receives 

frequent updates and improvements adding new features, bug fixes, and security enhancements.

System Setup

Athena systems are commissioned by a Lutron Field Service Engineer (FSE) using Lutron Designer software.

Connectivity

Athena systems are comprised of one or multiple connected processor / gateway devices that communicate 

with each other via a system Ethernet lighting control network. Internet access is required for system start-

up and highly recommended for ongoing system usage. The lighting control network can be cloud-enabled 

via the included LTE modem module or can be interfaced with an existing building IT network. If the Athena 

network does not have internet access, the Athena hub will not receive automatic firmware updates and the 

system will not be accessible remotely via the Lutron app.

LTE Modem

Lutron provides out-of-the-box cloud connectivity to Athena systems via an included LTE modem module 

for use during system start-up. This allows for a secure and seamless start-up, software updates, remote 

service / support, and fast and easy connectivity without any advanced network configuration. For ongoing 

internet connectivity, Lutron recommends connecting Athena processors to an internet connection that 

supports outbound requests. The LTE modem is currently not available for long term internet access and is 

only for start-up use.

Summary of Contents for Athena

Page 1: ...e and Support 3 Third Party Integration 3 Programming Features 4 Scenes 4 Keypads 4 Timeclocks 4 Occupancy 4 Load Shed 4 Daylighting 4 Device Replacement 4 System Expansion 4 Shade Limits 4 Trim Adjustment 4 Emergency Lighting 4 Operations and Maintenance 5 Introduction 5 Service Contact List 5 Safety Precautions 5 Maintenance Requirements 6 Hubs 6 Wall Controls 6 Sensors 6 Load Controller Panels ...

Page 2: ... a Lutron Field Service Engineer FSE using Lutron Designer software Connectivity Athena systems are comprised of one or multiple connected processor gateway devices that communicate with each other via a system Ethernet lighting control network Internet access is required for system start up and highly recommended for ongoing system usage The lighting control network can be cloud enabled via the i...

Page 3: ...p controls for zone types described below Load Type Intensity Control CCT Control Color Palette Ketra X X X 0 10 V static white X 0 10 V tunable white CCT INT X T Series X DMX X DALI X Contact Closures X Loads configured as DMX 1 channel in Lutron Designer will be shown with a 0 100 slider in the app Multi channel DMX fixtures may be configured as multiple 1 channel loads Scene editing Modify the ...

Page 4: ...single Lutron account setup in the app Multiple users will be able to access a single Athena system with individual myLutron accounts in a future update Software Updates Athena system software can receive updates via the cloud for new features and improvements Certain new features may require on site setup configuration or hardware additions For systems without Internet access systems can be updat...

Page 5: ...ettings are not available for editing in the app at this time Occupancy Occupancy programming and select sensor settings are defined in the Lutron Designer software Load Shed Load shed demand response is configured inthe Lutron Designer software and can be tested by an FSE in the Lutron Designer terminal It can then be activated via Athena Automated Demand Response Kit Daylighting Daylighting sett...

Page 6: ...s associated with each of the system s components devices Under no circumstances should Lutron supplied safety information and instructions supersede or be considered a substitute for your local organization s electrical safety procedures General Safety Precautions Only personnel with the proper electrical safety training qualifications should be permitted to perform maintenance on Lutron control ...

Page 7: ...teries as needed with the correct type of battery See the individual product installation sheet for battery specifications Warranty Information Please see the warranty enclosed with the product or visit http www lutron com en US ResourceLibrary warranty Lim_Warranty_starting_Oct2011 pdf For additional information please refer to the corresponding data sheet located at www lutron com athena Feature...

Page 8: ... Fax 1 610 282 1243 Visit us on the web at www lutron com support Lutron Electronics Co Inc 7200 Suter Road Coopersburg PA 18036 USA The Lutron logo Lutron Athena Clear Connect Pico and XCT are trademarks or registered trademarks of Lutron Electronics Co Inc in the US and or other countries Ketra is a trademark or registered trademark of Lutron Ketra LLC in the US and or other countries Apple App ...