5-15 Max and Min. value record

1)

Application : To record the maximum and the minimum 
reading value during the measurement.

2)

Push the " MAX/MIN button " ( 3-2, Fig. 1 ) at once ,
the display will show the " REC "  markers
Start recording meter the " MAX " and  " MIN " value.

3)

Push the " MAX/MIN button " ( 3-2, Fig. 1 ) once again
the display will show the " MAX " maker along with
the maximum measured value.
Push the " MAX/MIN button " ( 3-2, Fig. 1 ) once again
the display will show the " MIN " maker along with
the minimum measured value.

4)

If intend to cancel the "  MAX/MIN Record function" just
push the " MAX/MIN button "  ( 3-2, Fig. 1 ) > 2 seconds
the " REC " marker will disappear.

5-16 RS232 computer interface

1)

Connect the optional RS232 cable (UPCB-06) of
RS232 terminal (3-16, Fig. 1)

2)  The meter will be the serial data via

" RS232 Terminal " is transferred to the computer.

The data output is a 16 digit stream which can be
utilized  for user's specific application.

The 16 digits data stream will be displayed in the
following  format

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

16

Summary of Contents for DM-9962SD

Page 1: ...ward for you into the field of precision measurement Although this MULTIMETER is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are...

Page 2: ...oltage current to the input terminal Remove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories III 1000V...

Page 3: ...asurement 10 5 5 Continuity Check 11 5 6 Diode Test 11 5 7 Capacitance Measurement 13 5 8 Inductance Measurement 13 5 9 L C Calibration 14 5 10 Frequency Measurement 14 5 11 Temperature Measurement 15...

Page 4: ...OFF management 24 8 4 Set beeper sound ON OFF 25 8 5 Set Decimal point of Micro SD card setting 25 8 6 Set clock time Year Month Date Hour Minute Second 26 8 7 Set Change the Temp unit 26 9 MAINTENAN...

Page 5: ...istance Capacitance Inductance Frequency Temperature Diode Continuity beeper Max Min measurement value with recall Relative Data hold Auto range with manual range selection Temperature measurement pos...

Page 6: ...eeze the display reading on the LCD display Power On Off Auto power off or manual power off management Details please refer page 7 Memory recall Records Maximum Minimum readings with recall Relative m...

Page 7: ...Sub 9 connector UPCB 06 RS232 cable to USB connector USB 11 Micro SD card AC MICROSD Data Acquisition software SW U801 WIN SW E802 2 2 Electrical Specifications 23 5 DC Voltage Range 600 0 mV 6 V 60...

Page 8: ...age VF Range 2 9 V DC Accuracy 0 5 2d Capacitance Capacitance Capacitance Capacitance Auto Range 600 pF 6 nF 60 nF 600 nF 6 uF 60 uF 100 uF 600 uF Resolution 0 1 pF 0 001 nF 0 01nF 0 1 nF 0 001 uF 0 0...

Page 9: ...M 1 5 2d 60 M 3 5d Over load 350 DCV 350 ACV protection Continuity Beeper Beeper will sound if measured resistance less than 20 ohm Max Min Measurement During the operation can memorize the maximum a...

Page 10: ...3 3 TIME SET button 3 12 COM input terminal 3 4 REL Backlight button 3 13 mA uA input terminal 3 5 HOLD button 3 14 10A input terminal 3 6 RANGE button 3 15 Battery compartment Cover 3 7 V A Hz button...

Page 11: ...e Function Rotary Switch to the Off position when the instrument is not operation 7 Remove the battery if the instrument is not to be used in a long period of time 8 For safety consideration when chan...

Page 12: ...ax Appears when Max and Min value record Min function is operated Battery voltage is already under the low condition Appears when the Continuity beeper is operated mV V Units for voltage measurements...

Page 13: ...ll execute the Manual Range mode and hold the range the LCD will show the MANU marker Under the manual range operation push the Range button 3 6 Fig 1 2 seconds will return to auto range operation Rem...

Page 14: ...Fig 1 For the 10 A current measurement connect RED test lead into A terminal 3 14 Fig 1 Open the circuit in which current is to be measured Now securely connect test leads in series with the load in...

Page 15: ...al 2 Connect RED test lead into terminal 3 Select the Function rotary switch 3 10 Fig 1 to the position 4 The LCD display will show the marker 5 when the resistance value is less than 20 ohm the beepe...

Page 16: ...3 a reverse check on the diode is made If the diode under test is good will be displayed If the diode under test is defective 0 000 or other numbers will be displayed Proper diode testing should incl...

Page 17: ...When LCD show the AUTO marker the meter is under the auto range mode Meter will select the suitable measurement range automatically 4 Capacitance measurement mode no manual functions Range button 3 6...

Page 18: ...calibration data is saved to the EEPROM complete the calibration 5 10 Frequency Measurement 1 Connect BLACK test lead into COM terminal 3 12 Fig 1 2 Connect RED test lead into Hz terminal 3 11 Fig 1...

Page 19: ...3 4 Fig 1 at once then LCD will show zero value a REL indicator 2 The input measured values will deduct last measured values automatically then show those new value on the display 3 It will cancel th...

Page 20: ...n the display will show the MIN maker along with the minimum measured value 4 If intend to cancel the MAX MIN Record function just push the MAX MIN button 3 2 Fig 1 2 seconds the REC marker will disap...

Page 21: ...Hz 31 DC A 36 AC A 52 KHz 33 38 pF A4 MHz 67 K 39 uF 44 01 M 40 nF 43 02 DIODE 46 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8...

Page 22: ...ing format by the meter If the micro SD card exist the trouble during format by the meter If the micro SD card exist the trouble during format by the meter If the micro SD card exist the trouble durin...

Page 23: ...again the LOGGER symbol will flashing c Finish the Datalogger During execute the Datalogger function press the LOG Button 3 8 Fig 1 1 5 seconds continuously again will finish the Datalogger function...

Page 24: ...time and sampling time information During the normal measurement not execute the Datalogger If press Time 3 3 Fig 1 once the LCD display will present the time information of Year Month Date Hour Minu...

Page 25: ...d socket 3 18 Fig 1 2 Plug in the Micro SD card into the Computer s Micro SD card slot if your computer build in this installation or insert the Micro SD card into the Micro SD card adapter then conne...

Page 26: ...XCEL data screen for example EXCEL graphic screen for example graphic 22 50 70 90 110 130 150 170 190 210 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 A C V Graphic Ch1_Valu...

Page 27: ...OFF management bEEP Set beeper sound ON OFF dEC Set Micro SD card Decimal character dAtE Set clock time Year Month Date Hour Minute Second t CF Set Temperature unit or Remark In the implementation of...

Page 28: ...nual Datalogger or 2 3600 seconds to Auto Datalogger the adjusted value will be flashed When the desired value is set press the Enter key 3 8 Fig 1 once save the default sample value 2 sp t setting is...

Page 29: ...unction with default 8 5 Set Decimal point of Micro SD card setting When the display show dEC The numerical data structure of Micro SD card is default used the as the decimal for example 20 6 1000 53...

Page 30: ...rst setting value is Year then next to adjust Month Date Hour Minute Second value Remark The adjusted value will be flashed 2 After set all the time value Year Month Date Hour Minute Second press the...

Page 31: ...attery cover opening the battery cover opening the battery cover 1 When the LCD display showing the mark of it is necessary to replace the battery However in spec measurement may still be made for sev...

Page 32: ...not operation please check if the Fuse A is broken or not When the 10 A current range can not operation please check if the Fuse B is broken or not 3 When replace the fuse should take the test leads f...

Page 33: ...ect the meter to the computer COM port USB cable Computer interface cable USB 11 Used to connect the meter to the computer USB port Item Model Carrying Case CA 05A Light Adapter LX 02 EMF Adapter EMF...

Page 34: ...11 THE ADDRESS OF AFTER SERVICE CENTER 30 180525 DM 9962SD...

Reviews: