1. 

Disconnect power to the keypads by turning off all
circuit breakers connected to the HomeWorks

®

Processor or keypad link auxiliary power supply. 

Danger - 

Wiring with power ON may result in

personal injury. 

2. 

Address keypads.

Assign a unique address to

each keypad using the DIP switch on the back of
the keypad. See Figure 2 (page 3) for DIP switch
location. See Figure 3 (page 4) for DIP switch set-
tings. Be sure to record the address for future pro-
gramming purposes.

3. 

Strip insulation from wires to 3/8" (10mm). Each
terminal will accept one or two 18-gauge (1.0mm

2

)

wires.

4. 

Unplug terminal block from the keypad circuit
board.

5. 

Connect wiring to terminal block as shown in
Figures 1 and 2 (page 3).

6. 

Plug the keypad terminal block back onto the cir-
cuit board. Be sure to orient the terminal block
correctly.

7. 

Mount keypad as shown in Figure 4 (page 4). 

Do

not over-tighten mounting screws.

8. 

Restore power to the 

HomeWorks

Processor or

keypad link auxiliary power supply.

Mounting Diagram

Wallbox

Keypad

Mounting

Screws

Keypad

Adapter

Mounting

Screws

Wallplate and Adapter are purchased separately.

Included:

Mounting Screws (2)

Summary of Contents for Homeworks HWD-10KP

Page 1: ... connected per processor To increase the number of LEDs see the HomeWorks Technical Reference Guide Important Notes Codes Install in accordance with all local and national electrical codes Environment Ambient operating temperature 0 40 C 32 104 F 0 90 humidity non condensing Indoor use only Wallplates Lutron Claro and Satin ColorsTM wallplates are recommended for best color match and clean aes the...

Page 2: ...mming purposes 3 Strip insulation from wires to 3 8 10mm Each terminal will accept one or two 18 gauge 1 0mm2 wires 4 Unplug terminal block from the keypad circuit board 5 Connect wiring to terminal block as shown in Figures 1 and 2 page 3 6 Plug the keypad terminal block back onto the cir cuit board Be sure to orient the terminal block correctly 7 Mount keypad as shown in Figure 4 page 4 Do not o...

Page 3: ...to 32 1 2 3 4 5 6 7 8 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 9 10 11 12 13 14 15 16 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 17 18 19 20 21 22 23 24 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1...

Page 4: ...consequential damages so the above limitation or exclusion may not apply to you This product may be covered by one or more of the following U S patents 4 835 343 4 889 999 5 170 068 5 237 207 D344 068 D378 814 and corresponding foreign patents U S and foreign patents pending Lutron Claro and HomeWorks are registered trademarks and Satin Colors is a trademark of Lutron Electronics Co Inc 2003 Lutro...

Reviews: