background image

3

Low-Voltage (Class 2/PELV) Wiring Diagram

Keypads can be connected to
any of these three links
depending on the configuration
of the HomeWorks

®

Utility

Pins 1 & 2 - 1 pair #18 AWG (1.0mm

2

) for power

Pins 3 & 4 - 1 pair #18-22 AWG (1.0 - 0.5mm

2

twisted shielded for data

1 2 3 4

1 2 3 4 5 6

DIP switches 1-5 for
setting address, DIP
switch 6 does not
affect keypad address.

PELV (Class 2:
USA) wiring con-
nections to

HomeWorks

Wired Processor
or other Keypads.

MUX
MUX
+15VDC
COM

Keypad  Addressing

Set DIP switches 1-5 to give the keypad a unique 

HomeWorks

system address from 1 to 32.

1

2

3

4

5

6

7

8

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

9

10

11

12

13

14

15

16

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

17

18

19

20

21

22

23

24

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

25

26

27

28

29

30

31

32

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

Switch

Settings

Switch

Settings

Switch

Settings

Switch

Settings

Address

#

Address

#

Address

#

Address

#

1

2

3

4

5

6

ON

UP (ON)
DOWN (OFF)

Example: Setting Switch #1 ON.

Keypad Rear View

DIP Switches

Summary of Contents for Homeworks HWD-10KP

Page 1: ... connected per processor To increase the number of LEDs see the HomeWorks Technical Reference Guide Important Notes Codes Install in accordance with all local and national electrical codes Environment Ambient operating temperature 0 40 C 32 104 F 0 90 humidity non condensing Indoor use only Wallplates Lutron Claro and Satin ColorsTM wallplates are recommended for best color match and clean aes the...

Page 2: ...mming purposes 3 Strip insulation from wires to 3 8 10mm Each terminal will accept one or two 18 gauge 1 0mm2 wires 4 Unplug terminal block from the keypad circuit board 5 Connect wiring to terminal block as shown in Figures 1 and 2 page 3 6 Plug the keypad terminal block back onto the cir cuit board Be sure to orient the terminal block correctly 7 Mount keypad as shown in Figure 4 page 4 Do not o...

Page 3: ...to 32 1 2 3 4 5 6 7 8 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 9 10 11 12 13 14 15 16 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 17 18 19 20 21 22 23 24 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1...

Page 4: ...consequential damages so the above limitation or exclusion may not apply to you This product may be covered by one or more of the following U S patents 4 835 343 4 889 999 5 170 068 5 237 207 D344 068 D378 814 and corresponding foreign patents U S and foreign patents pending Lutron Claro and HomeWorks are registered trademarks and Satin Colors is a trademark of Lutron Electronics Co Inc 2003 Lutro...

Reviews: