background image

Lutron Electronics Co., Inc. 7200 Suter Road

Coopersburg, PA 18036-1299 USA

Customer Assistance  |  1.844.LUTRON1  

U.S.A. / Canada

  |  +1.888.235.2910 

Mexico

  |  +1.610.282.3800 

Others

  |  www.lutron.com/support

Part of the Vive System

Vive  Sensor  Dimmer / Switch

Wiring

  Start Here

English

Important Notes: 

•  Neutral is required for product to function. If a neutral wire is not present, 

consult a licensed electrician.

•  When controlling light and fan loads simultaneously on a single switch, 

the maximum load capacity per switch is 4.4 A at 120 V

~

. Only the 

sensor switch can be used to control fan loads.

•  When power is applied, the sensor dimmer / switch can be manually 

turned On / Off after the first 10 seconds and the sensor will 

automatically control the load after 2 minutes.

•  The sensor requires an unobstructed view of the room and line-of-sight 

to detect motion.

•  Hot objects or moving air currents can affect the performance of the 

sensor and may cause it to turn on unexpectedly or not function as 

desired.

• 

CAUTION:

 To reduce the risk of overheating and possible damage to 

other equipment, DO NOT use to control receptacles.

•  Class 2 / Class 1 wiring: Install in accordance with all national and local 

electrical codes.

•  For indoor use only. Operate between 32 °F – 104 °F (0 °C – 40 °C), 

ambient. 0% to 90% humidity, non-condensing.

•  Clean only with soft, damp cloth, DO NOT use chemical cleaners.

Maestro 0–10 V

-

 RF Sensor Dimmer

MRF2S-8SD010 

Occupancy / Vacancy

MRF2S-8SDV010 

Vacancy Only

Maestro RF Sensor Switch

MRF2S-8SS 

Occupancy / Vacancy

MRF2S-8SSV 

Vacancy Only

5.

 Wait two minutes.

 •  The sensor dimmer / switch will manually control the load after the first 10 seconds.
 •  Once power has been restored, the sensor dimmer / switch will automatically control the load after the first two minutes.

6.

 Program all desired settings before installing the wallplate.

 •  See other side of sheet for details on how to program settings.

2.

 Connect Wires.

1.

 Turn off power at the circuit breaker or fuse.

WARNING: Electric Shock Hazard.

 May result in Serious Injury or Death.  

Turn OFF power at circuit breaker or fuse before installing or servicing the unit.

4.

 Turn on power at circuit breaker or fuse.

WARNING: Electric Shock Hazard.

 Could result in minor or moderate personal injury. 

Ground connection required before connecting power.

Please read before installing

032538 

Rev. A

05/2019

For set-up, programming, and troubleshooting 

with a Vive system, please refer to the installation 

instructions included with the Vive hub or at  

www.lutron.com/vive

Compatible Devices for Sensor Dimmer

•   Works with all ballasts and drivers that provide a current source 

compliant to IEC 60929 Annex E.2. 

•   Supports Electronic Off functionality for voltages less than 0.5 V

Lighting

Sensor Dimmer

0-10 V

-

 electronic fluorescent ballast or LED driver

Sensor Switch

All lighting loads and up to 4.4 A fan loads

120/277 V

~

  50/60 Hz  8 A

Canada: 120 V

~

  50/60 Hz  8 A

0–10 V

-

 Load Rating (sink only)

•  One sensor dimmer can sink up to 50 mA of current.

•  Controls up to 25 drivers or ballasts.

•   IEC 60929 Annex E.2 requires each driver / ballast to limit the current 

draw to 2.0 mA maximum.

Motion Coverage

•  Major: 30 ft × 30 ft (9 m × 9 m) [900 ft

2

 (81 m

2

)]

•  Minor: 20 ft × 20 ft (6 m × 6 m) [400 ft

2

 (36 m

2

)]

Wireless Communication

•   Range of wireless communication is 60 ft (18 m) line-of-sight or 30 ft 

(9 m) through walls.

•   Keep all wireless devices visible within the space. Do not place behind 

large furniture or appliances. 

FCC Supplier Declaration to Conformity / IC Information

This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not 

cause interference and (2) This device must accept any interference, including interference that may cause undesired operation. Modification not expressly approved by Lutron Electronics 

Co., Inc. could void the user’s authority to operate this equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

• Re-orient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

For more information and additional wiring instructions, visit: www.lutron.com/TechnicalDocumentLibrary/048687.pdf and / or 
www.lutron.com/TechnicalDocumentLibrary/3691097.pdf

 

 

 

 

Arrêtez le Courant

Turn Off Power

Corriente

Desconecte la

1.844.588.7661

lutron.com

 

 

 

Arrêtez le Courant

Turn Off Power

Corriente

Desconecte la

1.844.588.7661

lutron.com

Gray (–)

Gray (–)

White

White

Gray (–)

Ballast or 

Driver

Ballast or 

Driver

Ballast or 

Driver

Ballast or 

Driver

White

White

Violet (+)

Violet (+)

Black

Black

Violet (+)

Black

Black

Ground

Ground

Green

Green

Black

Black

Black

Up to 25 drivers total and 
up to 50 mA maximum

Up to 25 drivers total 
and up to 8 A maximum

Black

White

White

Neutral

Neutral

Line / Hot

Line / Hot

120/277 V

~

  50/60 Hz  8 A

120 V

~

  50/60 Hz  8 A Canada

a. Sensor Dimmer - Single Pole Wiring

b. Sensor Switch - Single Pole Wiring

Associating wireless devices to a sensor dimmer / switch

Un-associating a wireless device from a sensor dimmer/switch

Programming with a Vive Hub

1. 

 Use an iOS

®

 or Android

®

  

compatible device.

1.

  Press and hold 

T

 until the      lights 

and the load lights flash (about 
7 seconds), then release. Note that 
after about 3 seconds the PIR lens 
will light up, but keep holding 

T

 until 

the other lights flash.

1.

  Triple-tap and hold the wireless device button 

until the device lights begin to flash rapidly. 
Within 1 second of flashing, release and triple-
tap the button again. The button does not need 
to be held after the second triple-tap.

2.

  Press and hold the wireless device button shown below until the lights 

stop flashing (about 6 seconds).

2.

  To test that the wireless device has been successfully  

un-associated, press “Test” or 

d

 and verify that the 

wireless device no longer controls the load.

2. 

 Download the Lutron Vive app.

3.

  Open the app and follow 

the instructions.

Note:

 For further information on set up, programming, and troubleshooting with a Vive system, please refer to the 

installation instructions included with the Vive hub or visit www.lutron.com/vive

 Notes:

•  

To

 

associate multiple wireless devices, repeat steps 1 and 2 above for each wireless device.

•  

To

 

exit this mode without associating device press and hold 

T

 until the lights stop flashing (about 7 seconds).

•  

For instructions on how to use or set up the Pico wireless control, please see  

   http://www.lutron.com/TechnicalDocumentLibrary/040429.pdf

•  

The device’s internal ambient light detecting (ALD) sensor is disabled when associated to a remote daylight sensor.

Pico wireless 

control 

(up to 10)

Radio Powr Savr 

daylight sensor 

(1 maximum)

Radio Powr Savr  

occupancy / vacancy  sensor   

(up to 10)

X

Vive

X

Test

Link

Test

Link

Test

Link

T

120/277 V

~

  50/60 Hz  8 A

120 V

~

  50/60 Hz  8 A Canada

120 V

~

  50/60 Hz  4.4 A Fan Loads

 

 

 

 

Arrêtez le Courant

Turn Off Power

Corriente

Desconecte la

1.844.588.7661

lutron.com

Note: 

The two black wires are interchangeable; either one can be wired to hot or switched hot.

Turn OFF power

Turn ON power

ML

Note:

 This will un-associate the wireless device from all devices, not just the Sensor Dimmer / Switch.

c.  For instructions on how to install these devices in a multi-location retrofit application such as 3-way installation, please refer to the 

app note located at www.lutron.com/TechnicalDocumentLibrary/048687.pdf

ML

3.

 Install device into the wallbox. Do not install wallplate at this time.

Summary of Contents for Maestro MRF2S-8SD010

Page 1: ...l device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferenc...

Page 2: ...nge If you want to increase the high end trim during programming process press R 4 Press and hold T until the ML turns off to lock your selection about 6 seconds Low End Trim3 4 1 Press and hold T and L simultaneously until a ML flashes about 6 seconds 2 Press and hold L until the bottom ML is reached and the lights dim down no further 3 Hold or tap R to increase the low end trim until the desired...

Page 3: ...limites d un appareil numérique de Classe B en vertu de la partie 15 des règles de la FCC Ces limites sont conçues pour fournir une protection raisonnable face aux interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre une énergie de fréquence radio et s il n est pas installé et utilisé conformément aux instructions il peut provoquer des interfére...

Page 4: ...s souhaitez augmenter le réglage du seuil haut pendant le processus de programmation appuyez sur R 4 Appuyez et maintenez T enfoncé jusqu à ce que le ML s éteigne pour verrouiller votre sélection environ 6 secondes Réglage du seuil bas3 4 1 Appuyez simultanément sur T et L et maintenez les enfoncées jusqu à ce qu un ML clignote environ 6 secondes 2 Appuyez et maintenez L enfoncé jusqu à ce que le ...

Page 5: ... invalidar la autorización del usuario para utilizar este equipo NOTA Este equipo ha sido comprobado y se lo encontró comprendido dentro de los límites para un dispositivo digital clase B según la sección 15 de las reglas de la FCC Estos límites están diseñados para proporcionar una protección razonable contra las interferencias perjudiciales en una instalación residencial Este equipo genera utili...

Page 6: ...n de la intensidad máxima dentro del rango ajustable Si desea incrementar el recorte de la intensidad máxima durante el proceso de programación pulse R 4 Pulse y mantenga pulsado T hasta que el ML se apague para bloquear su selección unos 6 segundos Ajuste de la intensidad mínima3 4 1 Pulse y mantenga pulsados simultáneamente T y L hasta un ML destelle aproximadamente seis segundos 2 Pulse y mante...

Reviews: