10
0697-501 MA/MI - 12/2020
en
Versions
Type
MA II
MI 4
Double-pole on/off switch
3
3
Single-pole thermal overcurrent release
3
3
Low voltage release
Optional
–
Protection class
I
1)
II
Protection class
IP 54
IP 24
H
max
(m wc)
2)
23
21
1)
Motors MA II 3-12, MA II 5-42 and MA II 5-24 correspond to protection class III.
2)
The maximum delivery head H
max
is a value determined by means of a test bench and measured
with water at a medium temperature of approx. 20°C. The measurement is carried out at the pres-
sure joint of the pump, without hose, nozzle or flow meter. The delivery head achievable in use is
lower and depends on the individual application, the media properties and the configuration of the
pump. The maximum delivery head is dependent on the pump design, motor and fluid.
Tab. 5: Available electrical designs
3.3 Function
Together with the respective pump tube, the motor types MA II and MI 4 are suitable for pumping
non-flammable, aggressive and thin-bodied liquids.
4. Transport and storage
4.1 Transport
Unpacking and checking condition of delivery
►
Unpack the motor on receipt and check for transport damages.
►
Report transport damages to the manufacturer immediately.
►
Check that the consignment is complete as ordered.
4.2 Storage
NOTICE
Damage of property as a result of incorrect storage!
►
Store the motor properly.
►
Store the motor protected from weather influences and UV rays.