10
– Insert the jet pipe for low pressure (8) into con-
necting pipe (7) and rotate by approx. 90° until
the two parts are securely connected (bayonet
connection).
– Remove the cleaning agent container (1) from
the holder.
– Fill the storage tank (1) with cleaning agent.
– Place the container in the holder and close the
lid.
– Set the jet pipe by adjusting the nozzle (22) to
low pressure.
– Switch on the machine.
– Spray the cleaning agent onto the dry surface
and let it soak (do not let dry).
– Set the jet pipe by adjusting the nozzle (22) to
high pressure.
– Use the high-pressure jet to rinse off any loos-
ened dirt.
Cleaning and maintenance
Overview of cleaning
Regularly, depending on conditions of use
Cleaning the water filter
– Remove the plug-in coupling for the water con-
nection (13).
– Remove the water filter (18) from the plug-in
coupling and clean using water.
– Remove contamination from the nozzle opening
using the needle provided and flush from the
front with water.
Clean the high-pressure jet nozzle
– Clean the nozzle by carefully inserting a needle
provided, or a thin and sharp instrument (i.e.
paperclip) into the nozzle to rid it of debris. Any
fine debris will cause the nozzle hole to become
clogged.
– Flush the debris out of nozzle by back flushing
(running the water through the nozzle backwards
or from the outside to the inside).
– Make sure all the debris have been cleaned or
knocked out of the nozzle.
Storing, transport
Storing
– Store the machine where it is dry and well venti-
lated.
– When placing the machine out of service for an
extended period of time, remove the cleaning
agent and drain all the water left in the hoses.
Transport
– If shipping, use the original packaging wherever
possible.
Malfunctions and troubleshooting
In the event of a malfunction…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the
vendor. You will save yourself a lot of trouble and
possibly money too.
DANGER! Risk of injury!
Before carrying
out any work on the product, ensure that
the mains plug is pulled out of the mains
socket and the product is depressurised.
What?
How?
Clean the machine.
Wipe the unit with a
slightly damp cloth Do
not clean the machine us-
ing a high-pressure water
jet.
Clean the high-pressure
jet nozzle.
NOTICE! Risk of machine damage!
Fro-
zen residual water may damage the
machine! If there is a danger of frost, store
the machine including all accessories in a
place protected from frost.
DANGER! Risk of injury!
Improperly con-
ducted repairs may prevent your machine
from working safely. Such repairs will
endanger you and your surroundings.
Fault/malfunction
Cause
Remedy
Machine is not running.
Machine is faulty?
Contact your local vendor.
No mains voltage?
Check cables, plug, socket and
fuse.
On/Off switch set to
[0]
?
Switch on the machine.
No or only little pressure is built up. Air in the system?
Ventilate the machine! Run the ma-
chine without the high-pressure
hose connected until water starts
leaking without bubbles. Re-attach
the high-pressure hose.
Leaks?
Check all inlet pipes leading to the
pump for leaks or clogs.
Setting of the high-pressure jet noz-
zle?
Check the setting on the hand-held
spray gun.
Adjusting the high-pressure wa-
GB
temp.book Seite 10 Donnerstag, 7. April 2016 9:55 09
Summary of Contents for 389842
Page 2: ...2 GB Original instructions 7 GR 12 temp book Seite 2 Donnerstag 7 April 2016 9 55 09...
Page 3: ...3 5 1 3 4 2 temp book Seite 3 Donnerstag 7 April 2016 9 55 09...
Page 4: ...4 16 3 17 4 5 6 7 8 9 18 10 temp book Seite 4 Donnerstag 7 April 2016 9 55 09...
Page 5: ...5 11 12 18 13 19 20 14 15 21 22 8 16 1 17 temp book Seite 5 Donnerstag 7 April 2016 9 55 09...
Page 6: ...6 18 19 temp book Seite 6 Donnerstag 7 April 2016 9 55 09...
Page 12: ...12 12 12 14 14 14 14 15 16 16 16 17 18 GR temp book Seite 12 Donnerstag 7 April 2016 9 55 09...
Page 13: ...13 FI 30 mA 18 GR temp book Seite 13 Donnerstag 7 April 2016 9 55 09...
Page 16: ...16 ON OFF 0 15 15 GR temp book Seite 16 Donnerstag 7 April 2016 9 55 09...
Page 19: ...19 temp book Seite 19 Donnerstag 7 April 2016 9 55 09...