74
Heater stand and location
The heater is primarily for outdoor use
only. Always ensure that adequate fresh air
ventilation is provided.
Always maintain proper clearance to
combustible materials, i.e. top 100 cm and
sides 100 cm minimum.
Heater must be placed on level fi rm ground.
Never operate heater in an explosive
atmosphere like in areas where gasoline or
other fl ammable liquids or vapors are stored.
To protect heater from strong wind, anchor
the base securely to the ground with screws.
Gas requirements
Use propane or butane gas only.
The pressure regulator and hose assembly
to be used must conform to local standard
codes.
The installation must conform to local codes,
or in the absence of local codes, with the
standard for the storage and handling of
liquid petroleum gases.
A dented, rusted or damaged propane tank
may be hazardous and should be checked by
your tank supplier. Never use a propane tank
with a damaged valve connection.
The propane tank must be arranged to
provide for vapor withdrawal from the
operating cylinder.
Never connect an unregulated propane tank
to the heater.
Leakage test
Gas connections on the heater are leak
tested at the factory prior to shipment.
A complete gas tightness check must
be performed at the installation site due
to possible mishandling in shipment or
excessive pressure being applied to the
heater.
Make a soap solution of one part liquid
detergent and one part water. The soap
solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear in
case of a leak.
The heater must be checked with a full
cylinder.
Make sure the safety control valve is in the
OFF position.
Turn the gas supply ON.