background image

terminais,  at  the  "INPUT  CAPA­

CITOR" position. By this selection, 

complete shut-off of DC ingredients 

from the external source is possible. 

The  color  of  light  will  return  to 

white from red within 2 ~3 seconds 

after selection. 

The  INPUT  CAPACITOR  IN/ 

OUT  SELE(;:TOR  is also useful for 

protection  of  the  amplifier  itself 

when  for  use  with  loading  com­

ponents  of  which  impedance  will 

bêCOme  nearly  zero  in  the  ex­

tremely  low  frequency  range;  for 

example,  electrostatic  (condenser) 

speakers,  speakers  using  dividing 

networks  that  use  transformers  for 

low frequency eut-off, etc. 

8. ATTENUA TOR

Input  sensitivity  can  be  regu­

lated  to  optimum  level  by  this 

control. 

Two  independent  at­

tenuators  are  provided  for the right 

and left channels and any unbalance 

of levels  between the both channels 

can  be  adjusted.  Viewed from  the 

rear  side  of  the  amplifier,  the  left 

knob  is  for  the  right  channel,  and 

the  right  knob,  the  left  channel. 

Continuous  input  level attenuation 

from  OdB  down  to 

00 

is possible. 

ClllaalHll--•■-

._. ..... 

� 

....... NII.._ 

fll.__ • 

.,.._Nlllllll 

PROt  CtOA 

UfCSWITCHCO  �. 

Ill  1111 

With  the knob  position completely 

turned  clockwise,  which  is  the 

MAX  position,  attenuation  amount 

is  0dB  (no  attenuation).  With  the 

knob  position  completely  turned 

counter-clockwise,  which  is  the 

MIN  position,  attenuation  amount 

is  infinite  (00) and  no  sound  play­

back  is possible.  The attenuator  is 

the  B type  volume  control  and  the 

attenuation  is  -6dB  (1 /2)  at  the 

neutral  (central) point  of the knob 

turning. 

9. EARTH TERMINAL

Earth terminais of exterior com­

ponent  such  as  a  preamplifier,  a 

peak  indicator and so forth must be 

connected  to  this  terminal.  To 

make  A/B  listening  test  of  am­

plifiers,  it  will  be  effective  to 

eliminate shock noise at changeover 

if  this  terminal  is  commonly  used 

for  grounding  of  the  tested  ampli­

fiers. 

10. PEAK INDICATOR

CONNECTOR

The  model  5E24  PEAK  IN­

DICATOR  to  give  precise  peak 

output  level  reading  of  the  am-

12. OVERCURRENT PROTECTION  FUSE 

11.  SPEAKER TERMINALS 

@  0 @  

• 

• 

L1

0.  PEAK  INDICATOR CONNECTOR 

14.  EXTRA  AC OUTLET 

6.  INPUT TERMINAL$ 

13.  AC  MAINS POWER CORD 

7.  INPUT CAPACITOR 

IN/OUT SELECTOR 

Summary of Contents for 5M21

Page 1: ...POWER AMPLIFIER A major breakthrougth amplifier technology a new series of amplifiers incorporating total DC design ensuring the most faithful sound reproduction with lowest phase and transient distor...

Page 2: ...dy rendered on the components as well as the circuitry made it possible to reduce it lower than even that of class A amp without sacrifice of output power The advantage of DC amp has been fully apprec...

Page 3: ...ing of meter sensitivity to the effect that ft AUYM PAOC SS O OC POw R AMP lf ICR t UXMAH SM lift CHAMMU 0dB indicates the maximum level may be inconvenient since the VU meter needle gives little or n...

Page 4: ...s illuminate To switch off the am plifier press in the switch once again 6 INPUT TERMINAL Outputs of the mating control pre amplifier are connected to these terminais Next to these terminais independe...

Page 5: ...evel attenuation from OdB down to 00 is possible ClllaalHll _ NII _ fll __ _Nlllllll PROt CtOA UfCSWITCHCO 0 Ill 1111 With the knob position completely turned clockwise which is the MAX position atten...

Page 6: ...FUSE This device is provided to protect the amplifier from breakdown caused by unexpected abnormal current flow within the circuit Especially it functions to protect the amplifier when short circuitin...

Page 7: ......

Page 8: ...racteristics The 5M21 is equipped with 2 large VU meters to show the average output level If you want to monitor the instantaneous peak output it is recommended to purchase the 5E24 peak indicator uni...

Page 9: ...of such stack Perfect fit between the legs and receptacles prevents each component unit from falling or sliding However if the unit is placed on the furniture or other kind of wooden cases with these...

Page 10: ......

Page 11: ...TAGE CUITlr 0 POWER REIAY L I SPEAKER 1 0305 0307 309 ill TERMINAL 0302 CONSTANT PNP T PNP T CURRENT ORIIIU PARAIIEI PUSH CURCUIT CIRCUIT FINAi STAGE 61V 5M21 5M20 Power Amp Section Block Diagram SECO...

Page 12: ...1 1 j 1 1 11 t 20KHz lQ HJ I r KHz o 1 o 2 0 2 0 1 0 05 02 0 01 o ____ J___ ___J_ o o 001 10 20 o 5 2 5 10 20 50 POWER W 5M21 5M20 T H O VS FREQUENCY 8 0 80TH CH ORIVEN t l _ 1 1 llJL_J_ 50 100 200 _w...

Page 13: ...Hz 4 l 8naoTH QI DIIIVEH DIST METER Sf 1700Bl r o 5 50 1 1 1 2 5 10 20 POWER W I 50 1 I 100 SM2l 5M20 FREQUENCY RESP0NSE tod8 100W an 80TH QI DIIIYEN 100 200 500 IK 2K FREQUENCY Hz 5K IOK 5M21 fllEQUE...

Page 14: ...30 10 3 0 20 t 10 u 0 f 20 30 20 50 tN UT CA ACITOPMN t DC 20 50 5M21 5M20 CROSSTALX POWER 100W VOLUME MAX 100 100 200 500 IK 2K FREQU NCY Hz _ 5K 5M21 5MZO PHASE CHARACTERISTIC 200 500 IK 2K FREQUENC...

Page 15: ...sions 442 W x 400 D x 146 H mm 17 13 32 X 15 3 4 X 5 3 4 Weight Net 19kgs 41 8 lbs 5M20J Gross 21kgs 46 2 lbs Power Output 1DOW minirr um continuous per channel into 8 ohm loads both channels driven a...