background image

SETTING THE TIME AND DAY

To change 
current day.

Open the drop down door on the front of the thermostat. Rotate the dial to the SET

DAY/TIME position. You should see the display pictured above with a day of the week flashing.
When you are finished setting the day and time, rotate the dial to RUN to return to normal
operation or to another position to continue programming.

C

A

U

T

I

O

N

The TX1500 is protected against normal static electric discharges.

However, in extremely dry weather you should touch another metal object

before the TX1500 to avoid potential loss of programs.

To change the
current time.

To set current time. The (e.g.
“12:00”) will be flashing.

The TX1500 alternately displays the

current time and the room 
temperature. It also displays the day of
the week and the currently active program period that is controlling the temperature: MORN,
DAY, EVE, or NIght.

The set point temperature will appear in the right side of the display. In the winter, set the

system switch to HEAT to control your heating system.  In the summer, set the switch to COOL
to control your air conditioner. In spring and fall or when windows are open, you can set the
system switch OFF.

Setting the FAN switch to AUTO

automatically runs your system’s fan
during heating and cooling. Setting the
FAN switch to ON runs your system’s
fan continuously even without heating
or cooling. 

N

O

T

E

The FAN switch works only if your system 

provides a wire for the TX1500’s “G” terminal.

• Press UP/DOWN to change the current temperature

setting. The OVERRIDE indicator appears on display.

• The OVERRIDE feature will be automatically canceled

at the start of the next program period.

• To cancel OVERRIDE prior to next program period press

UP/DOWN until original set temperature
appears. OVERRIDE indicator will disappear from display.

PROGRAMMING THE TX1500

You can change any preset times and/or temperatures to suit your schedules for the

weekday, Saturday and Sunday programs. Each period (Morning,
Day, Evening, and Night) is programmed for HEAT and for COOL. 

HEAT

OFF

COOL

Select HEAT to program the 

TX1500 for controlling your heater. 

To program temperature.

To change the start
time for MORN.

To move to DAY.

To change the temp. 
setting for MORN.

To program temperature.

To change start time 
for DAY.

To move to EVE.

To change the temp. 
setting for DAY.

To program temperature.

To change the start
time for EVE.

To move to NIGHT.

To change the temp.
setting for EVE.

To program temperature.

To change the start
time for NIGHT.

Rotate dial to RUN position to 

start the programs.

To change the temp.
setting for NIGHT.

Rotate dial to SET WEEKDAY PROGRAM. To program SATURDAY or SUNDAY, rotate the

dial to SET SATURDAY or SET SUNDAY PROGRAM. With dial on SET WEEKDAY
PROGRAM, you will see the display above.

TEMPORARY
TEMPERATURE OVERRIDE

TEMPERATURE OVERRIDE AND

TEMPERATURE HOLD 

SU

PM

DAY

TU

PM

EVE

HEAT

OVERRIDE

TU

AM

MORN

HEAT

PROGRAM

FOR:

MO

WE TH FR

START AT:

SET TEMP

DOWN

UP

These features let you change the current Set

Temperature without changing the programs stored
in your thermostat’s memory.

OR

Select COOL to program the

TX1500 for controlling your air conditioner.

OPERATION

This thermostat is “armchair programmable”

You can make any program or setting

changes with the thermostat body off or on

the wall thermostat base.

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

NEXT

UP

UP

UP

DOWN

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

UP

DOWN

Push in the RESET key. This sets

the built-in heating and cooling
programs. To review the built-in
programs, rotate the dial to SET
WEEKDAY / SATURDAY / SUNDAY
PROGRAM.

You can use the built-in 

programs as shown, or change them
as you wish. Each day is divided into
four periods. Each period has its
own starting time and temperature.

THE BUILT-IN 

E

NERGY

S

TAR

®

PROGRAMS

The dial must be in the RUN

position to close the door.

PERIOD

HEAT

COOL

WEEKDAYS

MORN

6:00 AM 70°

6:00 AM 78°

preprograms

DAY

8:00 AM 62°

8:00 AM 85°

EVE

6:00 PM 70°

6:00 PM 78°

NIGHT

10:00 PM 62° 10:00 PM 82°

MORN

6:00 AM 70°

6:00 AM 78°

SAT & SUN

DAY

8:00 AM 62°

8:00 AM 85°

preprograms

EVE

6:00 PM 70°

6:00 PM 78°

NIGHT

10:00 PM 62° 10:00 PM 82°

FILTER USAGE MONITOR

The FILTER Monitor counts the hours since the filter in your blower was last changed. After

250 hours of use, FILTER will appear in the display. After you change the filter, set the
thermostat’s FILTER Monitor back to zero as follows.

TEMPERATURE SWING

A thermostat works by turning your heating or cooling system on and off whenever the

room temperature varies a certain number of degrees from the set-point temperature. This
variation is the “swing.”

Your system should cycle on about 3 to 6 times per hour. A smaller swing number

increases the number of cycles, so room temperature is more constant. A larger swing
number decreases the number of cycles, to save energy in most cases.

TEMPERATURE CALIBRATION

SWING SETTINGS

PROGRAM LOCK

CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK

VACATION TEMPERATURE HOLD

TU

PM

EVE

HEAT

HOLD

HR

FILTER

HR

FILTER

SET

AM

MORN

HEAT

TH

To change the FILTER Usage Monitor limit 

To reset the
counter

Rotate the dial 
to FILTER

Rotate the dial to FILTER

To disable the FILTER Usage Monitor set the limit to 0 hours

To change the
limit from 
0-500 hours

Rotate the dial to 
SET DAY/TIME

Press together

To adjust the 
thermostat

To prevent tampering with set programs. 
The sequence of keys to lock and unlock the program:

Hold for two
seconds

Dial must be in 
the run position

Press together

ADVANCED FEATURES

SET TEMP SWING

To change 
swing

WARNING: Making these changes will require you to reset the thermostat.

• Located to the right of the gas electric switch are two black jumpers C/F and 24/12H.
• To change to Celsius - remove jumper - C/F.
• To change to a 24HR clock - remove jumper- 24/12H.
• Press the reset key on the front of the thermostat for 

changes to take effect.

• Reprogram as necessary.

ELECT

GAS

RL1

SW1

C/F

5/2 MIN
ON/OFF

24/12H

Press to set.

• Press HOLD. Adjust temperature as 

desired with UP/DOWN.

• Temperature setting will not change even 

after next program period begins.

• To clear, press HOLD again.

HOLD

NEXT

NEXT

HOLD

NEXT

NEXT

HOLD

NEXT

UP

UP

DOWN

UP

DOWN

UP

DOWN

NEXT

NEXT

HOLD

5 MIN/2 MIN MINIMUM ON/OFF TIME

Your thermostat has an internal timer built in to protect your compressor. The timer forces a

minimum on/off time of 5 minutes. You may change this minimum on/off time to 2 minutes. To
accomplish this, remove the jumper labeled 5/2 MIN. You must press the small reset button on
the face of the thermostat for the changes to take effect.

W

A

R

N

I

N

G

Making these changes will require you to reset the thermostat. Copy any of your customized

programs onto the blank chart. This will be your reference to re-enter the programs afterwards.

Reviews: