LUXCANADA.CA
15
TM
WIRING DIAGRAM (6-SPEED)
Wiring diagram shown above uses halogen lights. A transformer is required for LED lights.
TROUBLESHOOTING
IF THE RANGE HOOD OR HALOGEN LIGHTS DO NOT OPERATE AFTER INSTALLATION
Ensure the unit is plugged in and the power is on. Verify that a fuse has not blown and that all electrical
wiring is properly installed and connected.
Check for a defective bulb by replacing it with another known to be working properly (see the
Maintenance
section)
THE LIGHTS WORK BUT THE BLOWER IS NOT SPINNING, IS STUCK OR IS RATTLING
The blower might be jammed or scraping the bottom due to shipping damage. Please contact LUX
immediately.
Slots, holes and openings near the top of the upper chimney are used to exhaust cleaned air if range hood has been
converted into a purifying unit. If you did not install a re-circulation conversion kit, you do not need these slots, holes or
openings.
THE RANGE HOOD VIBRATES WHEN THE BLOWER IS ON
The range hood might not have been properly secured to the wall. Check with your installer.
THE HOOD IS NOT VENTING PROPERLY
Make sure the distance between the stove top and the bottom of the hood is 30” to 33” (note that due to
different ceiling heights, this recommended height may not be applicable).
Reduce the number of elbows and the length of duct work. Verify that all joints are properly connected,
sealed, and taped.
Make sure the power is on high speed for heavy cooking.
THE BLOWER OR FAN SEEMS WEAK
Check that the duct size is at least 6” or 3-1/4” x 10”. Range hood WILL NOT function efficiently if the duct
is too small or if the duct is loosely secured.
Check to see if the duct is clogged or if the damper unit (butterfly flappers) is installed correctly and is
opening properly. A tight mesh on a side wall cap unit might also cause restriction to the airflow.
Summary of Contents for VB30LCD
Page 5: ...LUXCANADA CA 5 HAUTEUR ET D GAGEMENT...
Page 7: ...LUXCANADA CA 7 OPTION 1 VACUATION HORIZONTALE PAR UN MUR...
Page 8: ...LUXCANADA CA 8 OPTION 2 VACUATION VERTICALE PAR LE TOIT...
Page 24: ...LUXCANADA CA 5 HEIGHT CLEARANCE...
Page 26: ...LUXCANADA CA 7 OPTION 1 HORIZONTAL WALL VENTING...
Page 27: ...LUXCANADA CA 8 OPTION 2 VERTICAL ROOF VENTING...