background image

036-21013-002 Rev. A (5/00)

Luxaire

                                                                                                                                                                                                                                

2

Unitary Products Group

TWO-STAGE UPFLOW/HORIZONTAL FURNACE DIMENSIONS

  

 

TWO-STAGE UPFLOW/HORIZONTAL RATINGS & PHYSICAL/ELECTRICAL DATA 

MODELS

  G8D--UH / 

L8D-UH

CABINET

 

WIDTH

 (

IN

.)

AFUE

*

*

AFUE numbers are determined in accordance with DOE test procedures.

LOW

 

FIRE

 

TEMP

 

RISE

 

°

F

HIGH

 

FIRE

 

TEMP

 

RISE

 °

F

MAX

OUTLET

 

AIR

 

TEMP

 

°

F

BLOWER

TOTAL

 

UNIT

 

AMPS

MAX

OVER

-

CURRENT

 

PROTECT

Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition).

For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. Refer to Form 650.74-N1.1V.

Wire size based on copper conductors, 60° C, 3% voltage drop.

Continuous return air temperature must not be below 55° F.

MIN

 

WIRE

 

SIZE

 

(

AWG

) @ 

75 

FT

ONE

 

WAY

OPER

 

WGT

(

LBS

)

INPUT

MBH

 

H

/

L

OUTPUT

 

MBH

 

H

/

L

NOM

CFM

HP

AMPS

SIZE

 (

IN

)

57/42

46/34

1200 

“A” 14-1/2

80.0

25 - 55

35 - 65

165

1/3

6.2

10 x 7

9.0

20

14

105

80/59

64/48

1200 

“A” 14-1/2

80.0

30 - 60

40 - 70

175

1/3

6.2

10 x 7

9.0

20

14

117

80/59

64/48

1600 

“B” 17-1/2

80.0

25 - 55

25 - 55

160

3/4

11.5

11 x 8

12.0

20

14

126

100/65

80/53

1200 

“B” 17-1/2

80.0

25 - 55

40 - 70

170

1/2

7.0

10 x 8

12.0

20

14

128

100/65

80/53

2000 

“C” 21 

80.0

25 - 55

30 - 60

160

1

12.2

11 x 10

14.0

20

12

145

120/78

96/64

1600 

“C” 21 

80.0

25 - 55

45 - 75

180

1/2

10.4

10 x 10

12.0

20

14

145

120/78

96/64

2000 

“C” 21 

80.0

25 - 55

35 - 65

170

1

12.2

11 x 10

14.0

20

12

147

TOP IMAGE

Vent Connection

(vent size)

D

20

 B 

Power

Wiring

7/8" K.O.

FRONT

E

5

F

1-7/ 8

BOTTOM IMAGE

1-1/ 8

20

FRONT

1-1/ 8

 A 

 C

7-3/ 8

3/4

F R O N T

F R O N T

L E F T   S I D E

L E F T   S I D E

R I G H T   S I D E

R I G H T   S I D E

OPTIONAL SIDE
RETURN CUT-OUT
(EITHER SIDE)

14

 GAS INLET
1-1/4" X 2-1/2"

2

2-1/4

1-1/8

D

(Vent Connection)

14-3/4

5-3/8

8-3/4

2-1/2

16

13-3/4

POWER WIRING

ACCESS
 WIRING

7/8" K.O.

32-1/2

T'STAT WIRING

7/8" K.O.

7/8" HOLE

 B 

40

 A 

 28-1/2 

 20

23-1/2

Upflow/Horizontal 

Models  G8D-UH / 

L8D-UH

A

B

C

D

E

F

G8D06012UHA11

*

*

L in the first character indicates LoNox.

14-1/2

13-1/4

10-1/8

4

10-1/8

3-3/4

G8D08012UHA11

*

14-1/2

13-1/4

10-1/8

4

10-1/8

3-3/4

G8D08016UHB11

*

17-1/2

16-1/4

13-1/8

4

11-5/8

3-3/4

G8D10012UHB11

17-1/2

16-1/4

13-1/8

4

11-5/8

3-3/4

G8D10020UHC11

*

21

19-3/4

16-5/8

4

13-3/8

3-3/4

G8D12016UHC11

21

19-3/4

16-5/8

4

13-3/8

3-3/4

G8D12020UHC11

*

21

19-3/4

16-5/8

4

13-3/8

3-3/4

Summary of Contents for G8D08016UHB11

Page 1: ...inducer operation Two speed blower operation This provides both increased comfort level and very quiet unit operation Delay timer allows two stage operation with single stage thermostat Acoustically i...

Page 2: ...0 25 55 25 55 160 3 4 11 5 11 x 8 12 0 20 14 126 100 65 80 53 1200 B 17 1 2 80 0 25 55 40 70 170 1 2 7 0 10 x 8 12 0 20 14 128 100 65 80 53 2000 C 21 80 0 25 55 30 60 160 1 12 2 11 x 10 14 0 20 12 145...

Page 3: ...5 1780 1695 1610 1505 1380 1225 MED 1725 1685 1650 1610 1555 1500 1425 1340 1220 1075 LOW 1365 1355 1325 1290 1265 1250 1210 1140 1045 940 100 80 2000 C 120 96 2000 C HIGH 2400 2320 2275 2200 2115 202...

Page 4: ...Blower Speed row 6 If the total system static falls between ESP values in the table i e 0 58 0 75 etc the static pressure may be rounded to the nearest value in the table determining the airflow usin...

Page 5: ...y permitted between lines formed by the intersection of the rear panel and side panel top in horizontal postion of the furance jacket and building joists studs or framing FILTER SIZE ADD ON COOLING MO...

Page 6: ...replaced Package contains six filter racks with filters External Bottom Return Upflow Or Horizontal End Return Filter Rack Provides a cleanable high velocity type filter and rack Attaches to the end...

Page 7: ...Luxaire 036 21013 002 Rev A 5 00 Unitary Products Group 7 NOTES...

Page 8: ...thout notice Printed in U S A CD 6 21014 036 21013 002 Rev A 5 00 Copyright by Unitary Products Group 2000 All rights reserved Supersedes Form 650 77 TG1U 1199 Unitary 5005 Norman Products York OK Gro...

Reviews: