Luxaire
036-21013-002 Rev. A (5/00)
Unitary Products Group
3
BLOWER PERFORMANCE - CFM - UPFLOW/HORIZONTAL (WITHOUT FILTER)
NOTE: Data below reflects air flows with single return opening, either left or right side or bottom.
MODELS: G8D--UH
/ L8D-UH
*
SPEED
TAP
EXTERNAL STATIC PRESSURE, INCHES W.C.
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
60 / 48 / 1200 / "A"
†
80 / 64 / 1200 / "A"
†
HIGH
1580
1530
1470
1405
1330
1245
1150
1045
890
650
MED-HIGH
1110
1100
1075
1060
1030
980
920
835
680
520
MED-LOW
845
840
830
815
790
750
670
595
480
320
LOW
675
665
660
645
620
585
530
455
360
255
100 / 80 / 1200 / "B"
HIGH
1675
1645
1595
1530
1465
1385
1280
1155
1025
810
MED
1270
1260
1250
1240
1215
1185
1125
1035
910
695
LOW
955
950
945
935
920
905
865
810
685
510
80 / 64 / 1600 / "B"
†
HIGH
1970
1935
1900
1850
1795
1735
1660
1590
1495
1395
MED
1445
1435
1425
1415
1405
1375
1350
1300
1240
1160
LOW
1245
1235
1225
1215
1205
1190
1170
1135
1090
995
120 / 96 / 1600 / "C"
HIGH
2040
1975
1925
1855
1780
1695
1610
1505
1380
1225
MED
1725
1685
1650
1610
1555
1500
1425
1340
1220
1075
LOW
1365
1355
1325
1290
1265
1250
1210
1140
1045
940
100 / 80 / 2000 / "C"
†
120 / 96 / 2000 / "C"
†
HIGH
2400
2320
2275
2200
2115
2025
1930
1825
1700
1570
MED
2050
2025
1980
1930
1855
1805
1720
1635
1530
1400
LOW
1690
1675
1660
1630
1610
1560
1500
1430
1330
1225
NOTE: Data below reflects airflows with two return openings - two sides or one side and bottom.
100 / 80 / 2000 / "C"
†
120 / 96 / 2000 / "C"
†
HIGH
2405
2340
2275
2210
2130
2050
1955
1840
1725
1600
MED
2005
1990
1965
1935
1880
1815
1725
1635
1535
1410
LOW
1655
1640
1625
1610
1585
1540
1485
1420
1340
1235
* Input / Output / CFM / Cabinet Type (A = 14-1/2, B = 17-1/2, C = 21, D = 24-1/2)
•
Airflow is expressed in standard cubic feet per minute
•
Motor voltage at 115V
†
Indicates LoNox models available
CLASS2SYSTEM
CONTROLWIRING
TOTHERMOSTAT
L1
(HOT) N
GRD
BLK
GRN
WHI
WIRINGINSIDE
JUNCTIONBOX
: BLK/BLK
WHI/WHI
GRN/GRN
BURNERCOMPARTMENT
BLOWERCOMPARTMENT
DOORSWITCH
IGNITIONMODULE
TRANSFORMER
JUNCTION
BOX
C
R
Y
G
W
C O OL
H E AT
P A RK
P A RK
X F MR
L INE
H U M
E A C
X F MR
E A C
L INE
C IR
H U M
Y
UPFLOW MODELS - ELECTRICAL WIRING