LX114
V. 01 – 18/09/2014
8
©Velleman nv
2.
Use UP or DOWN to select the 2, 3, or 7 channel DMX mode (2-CH, 3-CH, or 7-CH) and press
ENTER.
3.
Press MENU until <ADDRESS> is displayed and press ENTER.
4.
Use UP or DOWN to set the DMX starting address (d1–d512) and press ENTER.
DMX Channel Values
2-channel mode:
channel
function
from
to
description
1
warm white
000
255
from 0 to 100 %
2
cold white
000
255
from 0 to 100 %
3-channel mode:
channel
function
from
to
description
1
master dimmer
000
255
from 0 to 100 %
2
warm white
000
255
from 0 to 100 %
3
cold white
000
255
from 0 to 100 %
7-channel mode:
channel
function
from
to
description
1
master dimmer
000
255
from 0 to 100 %
2
warm white
000
255
from 0 to 100 %
3
cold white
000
255
from 0 to 100 %
4
strobe
000
009
no function
010
255
from slow to fast (1 to 20 Hz)
5
auto programme
000
051
no function
052
101
auto 1
102
152
auto 2
153
203
auto 3
204
254
auto 4
255
255
auto 5
6
auto programme speed
000
255
from slow to fast (0 to 100 %)
7
dimmer speed
000
051
default dimmer speed
052
101
linear dimmer
102
152
non-linear dimmer 1
153
203
non-linear dimmer 2
204
255
non-linear dimmer 3
8.
Cleaning and Maintenance
Before starting any cleaning or maintenance activities:
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
Cleaning
Clean the external optics with a soft cloth.
Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the unit operates (i.e. smoke, fog residue,
dust, dew).
Do not immerse the device in any liquid.
Maintenance
All screws should be tightened and free of corrosion.
The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in
mounting supports, do not change the location of the connections…
Mechanically moving parts must not show any signs of wear and tear.