4. Diagnostics and troubleshooting
4.1. Status indicator diagnostics — PSU, interlocks & cooling
Table 12 - Status indicator diagnostics
Indicator display
Status
Action
DC
INT
FLO
RF
MOD
Normal operation. Laser enabled.
No action required.
DC
INT
FLO
RF
MOD
Coolant flow rate is close to the
minimum flow rate. See section
.
• Check the coolant flow rate.
• Check for blockages or restrictions in
the cooling system pipes.
DC
INT
FLO
RF
MOD
No
RF Enable
signal.
Check the
RF Enable
signal.
DC
INT
FLO
RF
MOD
The modulation input is not within the
specified limits.
Check the modulation signal. See section
.
DC
INT
FLO
RF
MOD
No modulation input.
Check the modulation signal. See
.
DC
INT
FLO
RF
MOD
VSWR fault.
• If the indicator is intermittently red,
check the pre-ioniser fuse. See
• If the problem persists, contact
Luxinar Aftersales.
DC
INT
FLO
RF
MOD
RF power supply error.
Contact Luxinar Aftersales.
906-0227-00 REV 1
17
4. Diagnostics and troubleshooting