13 | 20

a long period of time in regions with heavy snowfall. 

Furthermore it must be ensured that the module is 

not located in the shade of plants or trees and that 

it is not damaged by flying sand and stones in strong 

winds.

In case of several rows of modules, reciprocal shading 

must be prevented by adhering to appropriate 

minimum distances.

  

Caution!  

Danger of insufficient fastening!

 

For free-standing installation on flat roofs, an 

edge clearance in accordance with DIN 1055 

Part 4 must be observed.

roof-parallEl Mounting

Sufficient rear ventilation of the modules must be 

ensured for roof-parallel mounting (at least 100 mm 

airspace between the module and the mounting 

surface).

Each penetration required for the installation of the 

module must be properly sealed to prevent the roof 

from leaking. 

 

 Caution!   

Danger of material damage!

 

Only use the existing mounting holes in the 

module frame (see dimensional drawing).  

Do not carry out any independent  

modifications on the module.

Depending on the module type, they have 8 or 16 

ventilation openings and 4 drainage openings in the 

module frame. During assembly, make sure that these 

openings are not covered. Keep a distance of 5 mil-

limetres between the modules, as they expand slightly 

when heated.

If possible, the modules should be mounted at an 

installation angle of at least 15° in order to support 

their self-cleaning effect.

The modules are suitable for on-roof, in-roof or free-

standing installation. Rod and mast mounting are also 

possible.

frEE-standing installation

During free-standing installation, particularly if located 

close to the ground, attention must be paid that the 

lower module area is also not covered with snow for 

!

!

Summary of Contents for eco line 60/225-235W

Page 1: ...ECo line Modules correctly mounted...

Page 2: ...Table of contents...

Page 3: ...3 20 Information regarding this manual Safety instructions Mechanical installation Electrical installation Troubleshooting maintenance 04 06 07 08 09 13 14 16 17 19...

Page 4: ...stood prior to installation In case of any questions please contact our sales department for further explanations During installation of the module the installer must adhere to all safety precautions...

Page 5: ...her third party rights resulting from the use of the PV product A license under a patent or patent rights shall not be granted neither by implication nor by any other way The information in these inst...

Page 6: ...local grid operators Regional building regulations 1 8 Product identification Each module has labels on the back containing the following information Identification label describes the product type r...

Page 7: ...the total current strength corresponds with the total of the current strengths of the individual modules Even contact with a direct current voltage Safety instructions of 30 volts or higher is potenti...

Page 8: ...entrate the sunlight onto the modules Do not expose the rear film to direct sunlight Do not use the module near equipment or in places where flammable gases are generated or may accumulate Do not dril...

Page 9: ...s should be orientated towards the south and vice versa You will find detailed information about the best angle of inclination for installation in specialised literature or from an experienced solar i...

Page 10: ...entilation hole d 7 mm C 8 x mounting hole d 7 mm D 2 x earthing d 2 mm 3 2 Dimensional module drawings Rear front side view Eco Line 60 240 250 W Tolerance L W 3 mm H the dimensions in the order conf...

Page 11: ...8 x ventilation hole d 7 mm C 8 x mounting hole d 7 mm3 D 2 x earthing d 2 mm A B C D 808 1000 A 4 x drainage 10 10 mm B 16 x ventilation hole 3 7 mm C 8 x mounting hole 14 9 mm3 D 2 x earthing d 2 mm...

Page 12: ...llowing drawing for detailed information Load calculations are per formed by the system designer or installer Depending on the assembly rack the modules can be fastened to the assembly rack by means o...

Page 13: ...e must be properly sealed to prevent the roof from leaking Caution Danger of material damage Only use the existing mounting holes in the module frame see dimensional drawing Do not carry out any indep...

Page 14: ...the conductors size of the fuses and size of the regulating devices connected to the modules or to the system output The open circuit voltage of the PV system must not exceed the maximum permissible i...

Page 15: ...ameters of the modules are also stated on the module type plate 4 2 Earthing Caution Danger of material damage Please observe the local regulations and provision for earthing Caution Danger of materia...

Page 16: ...ircuit voltage Check the open circuit voltage of each strand with a digital multimeter The measured values should corre spond with the total of the open circuit voltage for the individual modules You...

Page 17: ...module caused by a temperature increase of the solar cells or lower radia tion density 5 1 Block diodes and bypass diodes Caution Danger of electric shock Please observe the safety instructions for w...

Page 18: ...bypass diodes If the radiation density is not very low and the volt age between the terminals deviates by more than 5 then it is probable that the port is defective 5 3 Maintenance Caution Danger of e...

Page 19: ...high priority topic for Luxor This is why modules for disposal can be returned to Luxor for recycling Submission of the delivery note or invoice stating the date of purchase is required when returnin...

Page 20: ...49 711 88 888 999 F 49 711 88 888 911 info luxor solar com www luxor solar com Printed on Recystar Polar a recycling paper with FSC certificate and the Blue Angel eco label klimaneutral gedruckt Zert...

Reviews: