13 | 20
a long period of time in regions with heavy snowfall.
Furthermore it must be ensured that the module is
not located in the shade of plants or trees and that
it is not damaged by flying sand and stones in strong
winds.
In case of several rows of modules, reciprocal shading
must be prevented by adhering to appropriate
minimum distances.
Caution!
Danger of insufficient fastening!
For free-standing installation on flat roofs, an
edge clearance in accordance with DIN 1055
Part 4 must be observed.
roof-parallEl Mounting
Sufficient rear ventilation of the modules must be
ensured for roof-parallel mounting (at least 100 mm
airspace between the module and the mounting
surface).
Each penetration required for the installation of the
module must be properly sealed to prevent the roof
from leaking.
Caution!
Danger of material damage!
Only use the existing mounting holes in the
module frame (see dimensional drawing).
Do not carry out any independent
modifications on the module.
Depending on the module type, they have 8 or 16
ventilation openings and 4 drainage openings in the
module frame. During assembly, make sure that these
openings are not covered. Keep a distance of 5 mil-
limetres between the modules, as they expand slightly
when heated.
If possible, the modules should be mounted at an
installation angle of at least 15° in order to support
their self-cleaning effect.
The modules are suitable for on-roof, in-roof or free-
standing installation. Rod and mast mounting are also
possible.
frEE-standing installation
During free-standing installation, particularly if located
close to the ground, attention must be paid that the
lower module area is also not covered with snow for
!
!