15 | 20
The direct current generated by photometric systems
can be converted into alternating current and fed into
the local grid. As the grid operators have different
infeed conditions from town to town for the connec-
tion of renewable energy systems, contact with the
responsible grid operator should be made in due
time. Approvals for the installation of such a system
are usually required (application for grid connection).
Connection to the grid may only be carried out by a
licensed electrician.
Please refer to the valid module datasheet
for detailed module data. The electrical rated
parameters of the modules are also stated
on the module type plate.
4.2 Earthing
Caution!
Danger of material damage!
Please observe the local regulations and
provision for earthing.
Caution!
Danger of material damage!
Bolts, screws or other earthing connections
may not be used to fasten the module to the
assembly rack.
The modules have two holes (2 mm) on the back for
fastening the potential equalisation in the module
frame.
4.3 Cabling
Caution!
Danger of electric shock!
Please observe the safety instructions for
working with direct current!
Caution!
Danger of electric shock and burns!
Do not disconnect the plug-in module con-
nections under load! Otherwise non-extin-
guishing electric arcs may result.
The modules are pre-conditioned with fixed cables
and MC4 plug connections. Only use suitable and
!
!