equivalent plug connections for the wiring. 

Only use special, UV-resistant solar cables and suit-

able connectors. Do not bend the cables and observe 

the minimum bending radius. Please make sure that 

the cables are laid such that they cannot rub against 

sharp-edged objects or 

roof tiles. UV-resistant cable ties, for example, are 

suitable for fastening.  Some mounting systems also 

have special cable fastenings and guides. Make sure 

the the cables are not installed under tensile stress. 

Replace damaged cables.

If possible, ensure short cable lengths to minimise 

intrinsic losses.

Please check the open circuit voltage and the short 

circuit current for each installed strand (see also 

section 4.4).

4.4 tEst

Test all electric and electronic components of the sys-

tem before use. Follow the instructions in the manuals 

provided with the components and equipment. 

Perform a test of the open circuit voltage and short 

circuit current before connection of the system.

opEn CirCuit VoltagE

Check the open circuit voltage of each strand with a 

digital multimeter. The measured values should corre-

spond with the total of the open circuit voltage for the 

individual modules. You will find the nominal voltage in 

the datasheet of the module used*. If the measured 

value is substantially lower than the expected value, 

continue in accordance with the section "Trouble-

shooting at low voltage".

short CirCuit CurrEnt

Test the short circuit current of each series circuit. 

This can be measured directly with a digital multim-

eter, which is connected to two clamping plates of the 

series circuit or module, or with any load, such as e. g. 

PV lighting, in order to carry out a rough measure-

ment. Please make sure that the nominal scale of the 

ampere meter or the rated current of the load must 

amount to 1.25 times the rated short circuit current 

of the series module. You will find the rated current 

in the datasheet of the module used. The measured 

value can vary strongly depending on the weather, 

time of day and possibly the shade.

*  The electrical values of the provided individual measurements al-

located to the respective serial number are decisive.

Summary of Contents for eco line 60/225-235W

Page 1: ...ECo line Modules correctly mounted...

Page 2: ...Table of contents...

Page 3: ...3 20 Information regarding this manual Safety instructions Mechanical installation Electrical installation Troubleshooting maintenance 04 06 07 08 09 13 14 16 17 19...

Page 4: ...stood prior to installation In case of any questions please contact our sales department for further explanations During installation of the module the installer must adhere to all safety precautions...

Page 5: ...her third party rights resulting from the use of the PV product A license under a patent or patent rights shall not be granted neither by implication nor by any other way The information in these inst...

Page 6: ...local grid operators Regional building regulations 1 8 Product identification Each module has labels on the back containing the following information Identification label describes the product type r...

Page 7: ...the total current strength corresponds with the total of the current strengths of the individual modules Even contact with a direct current voltage Safety instructions of 30 volts or higher is potenti...

Page 8: ...entrate the sunlight onto the modules Do not expose the rear film to direct sunlight Do not use the module near equipment or in places where flammable gases are generated or may accumulate Do not dril...

Page 9: ...s should be orientated towards the south and vice versa You will find detailed information about the best angle of inclination for installation in specialised literature or from an experienced solar i...

Page 10: ...entilation hole d 7 mm C 8 x mounting hole d 7 mm D 2 x earthing d 2 mm 3 2 Dimensional module drawings Rear front side view Eco Line 60 240 250 W Tolerance L W 3 mm H the dimensions in the order conf...

Page 11: ...8 x ventilation hole d 7 mm C 8 x mounting hole d 7 mm3 D 2 x earthing d 2 mm A B C D 808 1000 A 4 x drainage 10 10 mm B 16 x ventilation hole 3 7 mm C 8 x mounting hole 14 9 mm3 D 2 x earthing d 2 mm...

Page 12: ...llowing drawing for detailed information Load calculations are per formed by the system designer or installer Depending on the assembly rack the modules can be fastened to the assembly rack by means o...

Page 13: ...e must be properly sealed to prevent the roof from leaking Caution Danger of material damage Only use the existing mounting holes in the module frame see dimensional drawing Do not carry out any indep...

Page 14: ...the conductors size of the fuses and size of the regulating devices connected to the modules or to the system output The open circuit voltage of the PV system must not exceed the maximum permissible i...

Page 15: ...ameters of the modules are also stated on the module type plate 4 2 Earthing Caution Danger of material damage Please observe the local regulations and provision for earthing Caution Danger of materia...

Page 16: ...ircuit voltage Check the open circuit voltage of each strand with a digital multimeter The measured values should corre spond with the total of the open circuit voltage for the individual modules You...

Page 17: ...module caused by a temperature increase of the solar cells or lower radia tion density 5 1 Block diodes and bypass diodes Caution Danger of electric shock Please observe the safety instructions for w...

Page 18: ...bypass diodes If the radiation density is not very low and the volt age between the terminals deviates by more than 5 then it is probable that the port is defective 5 3 Maintenance Caution Danger of e...

Page 19: ...high priority topic for Luxor This is why modules for disposal can be returned to Luxor for recycling Submission of the delivery note or invoice stating the date of purchase is required when returnin...

Page 20: ...49 711 88 888 999 F 49 711 88 888 911 info luxor solar com www luxor solar com Printed on Recystar Polar a recycling paper with FSC certificate and the Blue Angel eco label klimaneutral gedruckt Zert...

Reviews: