I N S T A L L A T I O N G U I D E
4
5
6
STEP 2-3 (Conduit-surface) (Figure 4)
1. Drill holes on the rear cover as auxiliary mounting holes.
2. Verify that supply power is off. Using a contractor level, ensure rear cover is level
and mark mounting surface thru selected ausiliary mounting holes.
3. Drill holes as marked in Step 1 and install appropriate mounting inserts capable of
handling fixture load requirements.
4. Ensure rear cover is level. Fully tighten fasteners (use washers as required to
ensure a secure fit).
5. Attach 1/2” NPT conduit fittings using the appropriate EMT rain tight compression
connections (not provided) onto the factory machined conduit entry opening.
STEP 3
Make supply wire (power and dimming) to fixture wire connections as required thru
splice access. Universal voltage driver permits operation at 120V thru 277V, 50 or
60Hz 0-10V control wires must be rated for 300V minimum. For 0-10V Dimming,
follow the wiring directions as shown on the figure to the left.
STEP 4 (Figure 5)
Fixture slightly upward, align fixture housing indicators with rear cover hooks and
slip fixture back onto hooks and insert the connector.
STEP 5 (Figure 6)
Close the housing indicators to the rear cover and fully tighten fasteners.
BLACK
WHITE
GREEN
PURPLE
GRAY
LINE
COMMON
GROUND
DIM+
DIM-
Conduit
Rear Cover
Housing Indicators
Auxillary
Mounting Holes
Supply Wire
Rear Cover
Rear Cover
Screws
TROUBLESHOOTING
If this fixture fails to operate properly, check to make sure: The fixture is wired correctly. The fixture is grounded correctly. The line voltage at the fixture is correct. If all these
variables have been checked and the fixture still does not operate as specified, contact your local distributor.