LX Navigation d.o.o. LX 7007 C May. 30th 2012
- 41 -
4.3
Pneumatic connections
Three pressure connectors are fitted to the back of the vario unit.
A label shows their functions.
Ptot = Pitot or Total pressure
TE = TE probe
Pst = Static
Electronic TE compensation schematics (Set TE 100%)
TE/Pst Static
Pst Static
Ptot Pitot or Total pressure
instrument panel
selector axis
press-in cover
special type screw
rotary knob
LX5000