E-EQ-BRSCHGROGWW-B
Bluetooth Ring Scanner Battery Charger User’s Guide
Technical Specifications
Operating Temperature Ranges
Multi-Charger
Minimum
Maximum
Comment
Operating 0°C
(32°F)
+45°C
(113°F) Battery packs will only be charged when their temperature
is between 0°C (32°F) and 40°C (100°F).
Charging 0°C
(32°F) +45°C
(113°F) Battery packs will not begin charging if their temperature
is outside this range.
Storage
-10°C (14°F)
+50°C (120°F)
Unit is off.
Single-bay Charger
Minimum
Maximum
Comment
Operating 0°C
(32°F)
+40°C
(100°F) Battery packs will only be charged when their temperature
is between 0°C (32°F) and 40°C (100°F).
Storage
-10°C (14°F)
+50°C (120°F)
Unit is off.
Electrical
Parameter Min
Max.
Comment
Power Supply Input
Voltage (V
AC-IN
)
100 VAC
240VAC
Auto-switching
Power Supply Input
Frequency (freq)
47Hz 63Hz
Note:
Battery packs may leak up to 1mA current through the battery contacts when left in an unpowered
charger battery well.