background image

10 

Introduction 

Bluetooth Ring Scanner Guide 

E-SW-BLUESCANPG-B 

Insert Battery 

Orientation

:  Bluetooth 

LED

 on the module is up. 

Insert a fully charged battery into the battery bay, making sure the battery 
terminals enter the battery bay at the right side of the battery opening. Use the 
direction of the arrow on the battery label as a guide. 

 

 

 

Close 

Orientation

:  Bluetooth 

LED

 on the module is up. 

Press down on the battery until it is seated in the battery bay and close the 
battery bay hatch cover. Slide the battery latch to the left to secure the battery 
in the Bluetooth Module. The Bluetooth module beeps happily 

2

 and it’s LED 

flashes. 

 

Note: 

Do not use a metal object, or extreme force, to remove the battery from the module. 

If a ring scanner is tethered to the Bluetooth module while a battery is being hotswapped 

and 

there is no beep or LED flash,

 remove the battery, turn it over and reinsert, making sure the 

battery terminals enter the battery bay to the right. Slide the battery bay latch to the left to secure 
the battery in the Bluetooth Module. If there is sufficient power in the battery, the Bluetooth 
module beeps happily and the LED flashes. 

Adjusting the Ring Device Strap 

The 

ring scanner finger loop

 is located under the ring scanner.  

Pull gently on the end of the finger loop strap to separate the hook and loop fabric.  

Slide your finger into the opened loop under the ring scanner.  

 

 

Grasp the end of the finger loop strap and gently pull to loosen, then tighten, the finger strap until 
the ring scanner is comfortably snug and the scan aperture is in the desired location. Secure the 
ring strap at the desired location by pressing the hook fabric (under the yellow label) to the loop 
fabric on the strap surrounding the finger. 

The ring scanner has a built-in quick disconnect designed for occasional safety hazards. The quick 
disconnect is not intended for daily removal of the ring scanner. 

                                                           

2

   Short low tone beep, Long low tone beep, Long high tone beep 

Summary of Contents for E-SW-BLUESCANPG-B

Page 1: ...uetooth Ring Scanner Guide Barcodes in this guide must be printed on a 600dpi printer The barcodes cannot be scanned from a computer monitor Copyright 2009 by LXE Inc All Rights Reserved E SW BLUESCANPG B ...

Page 2: ...the Stylized M Logo are registered trademarks of Motorola Inc The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc and any use of such marks by LXE Inc is under license When this guide is in PDF format Acrobat Reader Copyright 2006 2009 Adobe Systems Incorporated All rights reserved Adobe the Adobe logo Acrobat and the Acrobat logo are trademarks of Adobe Systems Incorporated Appli...

Page 3: ...rs 12 Bluetooth Module Status LED and Beep Indicators 13 Bluetooth Ring Imager LED and Ring Scanner LED 14 Bluetooth Module Reboot Sequences 15 Suspend 15 Reboot 15 Reset 15 Battery 15 Battery Low 15 Battery Dead 15 Removing Replacing the Trigger Module 16 Remove Finger Strap Assembly 16 Replace 17 Removing Replacing the Ring Finger Strap Assembly 17 Cleaning the Beam Aperture 17 Bluetooth Module ...

Page 4: ...val Timeout 35 Reconnect Timeout 37 Role Switching 38 Authentication 39 Encryption 39 Imager White LEDs 40 Beep Volume 41 Ring Imager Focus Mode 42 Enter Friendly Name or PIN Code 43 PIN Code 43 Friendly Name 44 Numbers 45 Lowercase Letters 47 Uppercase Letters 53 CHAPTER 3 SE955 LASER BARCODES 59 Introduction 59 Aiming Modes 60 Prefix Suffix 60 Pre Configured Default Values 61 Beep on BEL 65 Freq...

Page 5: ...er Time out 92 Host Serial Response Time out 93 Intercharacter Delay 93 Parity 94 Software Handshaking 95 Disable ACK NAK Handshaking 95 Enable ACK NAK Handshaking 95 Stop Bit Select 96 Transmit No Read Decode Message 97 Trigger Mode 98 Scanner Parameters SE955 Barcode Type Specific 100 Chinese 2 of 5 100 Codabar 100 CLSI Editing 101 NOTIS Editing 101 Set Lengths for Codabar 102 One Discrete Lengt...

Page 6: ...nterleaved 2 of 5 124 I 2 of 5 Digit Verification 125 Convert I 2 of 5 to EAN 13 126 Set Lengths for I 2 of 5 127 One Discrete Length Parameter L1 127 Two Discrete Lengths Parameter L2 128 Length Within Range 128 Any Length 129 Transmit I 2 of 5 Check Digit 129 MSI Plessey 130 MSI Plessey Check Digit Algorithm 130 MSI Plessey Check Digits 131 Set Lengths for MSI Plessey 132 One Discrete Length Par...

Page 7: ...arcodes SE4400 160 Reset Cancel Barcodes 160 Enable Disable Parameter Scanning 161 Configure Imager For Barcode Types 162 2D Symbologies 162 Codabar 164 Code 11 164 Code 39 165 Code 93 165 Code 128 166 Composite 166 Interleaved 2 of 5 167 Discrete 2 of 5 168 ISBT 128 168 MSI Plessey Code 169 Postal Codes 169 GS1 DataBar RSS 171 UPC EAN 172 Imager Parameters General 174 Decode Session Timeout 174 D...

Page 8: ...ode 210 Code 128 211 UCC EAN 128 211 ISBT 128 212 Code 39 213 Trioptic Code 39 213 Convert Code 39 to Code 32 214 Code 32 Prefix 214 Set Length s for Code 39 215 One Discrete Length Parameter L1 215 Two Discrete Lengths Parameter L2 215 Length Within Range 216 Any Length 216 Code 39 Check Digit Verification 217 Transmit Code 39 Check Digit 218 Code 39 Full ASCII Conversion 219 Code 93 220 Set Leng...

Page 9: ... 241 One Discrete Length Parameter L1 242 Two Discrete Lengths Parameter L2 242 Length Within Range 243 Any Length 243 MSI Check Digits 244 Transmit MSI Check Digit 245 MSI Check Digit Algorithm 246 Postal Codes 247 US Postnet 247 US Planet 247 UK Postal 248 Transmit UK Postal Check Digit 248 Japan Postal 249 Australian Postal 249 Dutch Postal 250 Transmit US Postal Check Digit 251 4State Postal 2...

Page 10: ...1 Decode Zones 271 SE955 I000WR Standard Range Laser Scanner 272 SE4400 Laser Imager 273 Near Focus Decode Distances 273 PL4407 273 MS4407 273 Far Focus Decode Distances stopped here 274 PL4407 274 MS4407 274 Toggled Focus Decode Distances 275 PL4407 275 MS4407 275 Decode Distances in Darkness 276 PL4407 276 APPENDIX 277 BlueCore Device Firmware Update Installation Instruction 277 Install BlueCore...

Page 11: ... Label 8 Figure 1 11 Bluetooth Ring Scanner Assembled 11 Figure 1 12 Module LED Beeper and Ring Scanner LED 12 Figure 1 13 Step 1 Rotate Trigger Module and Remove Screw 16 Figure 1 14 Step 2 Rotate Trigger Module again until it pops up Remove the trigger module 16 Figure 1 15 Replace Trigger Module 17 Figure 1 16 Scanning Angle for Linear Barcodes 20 Figure 1 17 Scanning a 2D Barcode 21 Figure 3 1...

Page 12: ...x Table of Contents Bluetooth Ring Scanner Guide E SW BLUESCANPG B ...

Page 13: ... Type before scanning any barcode in this programming guide Note The function to use the imager for OCR decoding is not supported in this release When using the ring device to scan the barcodes in this guide the user can change scanning parameters for the Bluetooth Module such as Enable disable suspend timeout length Set the Beeper volume Bluetooth module only Assign a Friendly Name and Restore th...

Page 14: ...canner Programming Guide Figure 1 1 Ring Tether Connectors The Bluetooth Ring Scanner assembly provides wireless communication with the following Bluetooth enabled LXE computers HX2 Body Worn HX3 Voice Body Worn MX3Plus Handheld MX3X Handheld MX7 Handheld MX8 Handheld MX9 Handheld VX3Plus Vehicle Mount VX3X Vehicle Mount VX6 Vehicle Mount VX7 Vehicle Mount LXE Tethered Scanners and Mobile Bluetoot...

Page 15: ...e to any other device Caution Laser radiation when open Please read the caution labels Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Class 2 laser scanners use a low power visible light diode As with any very bright light source such as the sun the user should avoid staring directly into the light beam Momentar...

Page 16: ...lens Note Imagers and scanners use laser beams when scanning a barcode The ring scanner has an SE955 scan engine see Chapter 3 for programming barcodes The ring imager has an SE4400 scan engine see Chapter 4 for programming barcodes Carefully look at the laser apertures of your ring scanning devices Figure 1 3 Ring Imager L and Ring Scanner R Figure 1 4 Ring Imager L and Ring Scanner R Apertures 1...

Page 17: ...n with the following Bluetooth enabled LXE computers HX2 Body Worn HX3 Voice Body Worn MX3 CE Handheld MX7 Handheld MX8 Handheld VX3 CE Vehicle Mount VX6 Vehicle Mount VX7 Vehicle Mount The Bluetooth tethered ring scanner and tethered ring imager connectors are not interchangeable with other LXE mobile devices that also use tethered ring scanners ring imagers i e HX2 HX3 The scan engine manufactur...

Page 18: ...e The Bluetooth Module ring scanner and ring imager connectors are not interchangeable with the ring scanner and ring imager connectors designed for the HX2 or the HX3 mobile device Figure 1 6 Components Module 1 Battery Compartment Latch 2 Speaker 3 LED 4 I O Port Ring Device Cable Connection ...

Page 19: ...sing The ring devices do not have the ability to emit a good read or bad read sound The Bluetooth Ring Scanner module emits good read or bad read sounds based on the ring scan results See section titled Status LED and Beep Indicators for an explanation of the LED and beep patterns emitted by these devices Note These ring decoding devices do not have the ability to emit a good read or bad read soun...

Page 20: ... ID Barcode Label Locate the barcode label similar to the one shown above attached to the LXE Bluetooth capable mobile device It may be on any side of the device The label is the Bluetooth address identifier for the LXE Bluetooth capable mobile device It must be scanned before LXEZ Pairing connection can occur The barcode label on the Bluetooth Ring Scanner module is a barcode and numeric represen...

Page 21: ...E logo on the module protective sleeve is up visible Slip the ring cable connector through the ring cable guide on the side of the Bluetooth module sleeve The connector can be inserted from the left or the right The ring cable guides are designed to minimize excessive pulling or tugging on the scanner cable after the ring scanner is connected to the Bluetooth module Press the connector firmly into...

Page 22: ... and reinsert making sure the battery terminals enter the battery bay to the right Slide the battery bay latch to the left to secure the battery in the Bluetooth Module If there is sufficient power in the battery the Bluetooth module beeps happily and the LED flashes Adjusting the Ring Device Strap The ring scanner finger loop is located under the ring scanner Pull gently on the end of the finger ...

Page 23: ...Introduction 11 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Assembled Worn on left hand on back of hand Worn on right hand on back of wrist Figure 1 11 Bluetooth Ring Scanner Assembled ...

Page 24: ...e cases the receipt of data from the ring scanner triggers a good scan beep from the Bluetooth module and then the rejection of scanned barcode data by the paired mobile device e g MX8 processing causes a bad scan beep from the paired mobile device MX8 on the same data Please see the mobile device specific guide for an explanation of the LED and beep indicators for the paired device For example if...

Page 25: ... Beep on Connect is enabled See LXE Programming Barcodes Fast blink 0 25 sec duration every 1 0 sec Lost Connection Short high tone beep Short low tone beep When Beep on Connect is enabled See LXE Programming Barcodes Slow blink 0 25 sec duration every 4 0 sec Connected None Fast blink 0 25 seconds every 1 0 second Not Connected None Off Suspend or Off not tethered or no battery power available in...

Page 26: ...ooth Module Beep Green User Good Scan Short high beep Green Configuration Good Scan Note This means the configuration process is successful Three Short high beeps Red Scan in progress None Red Configuration Bad Scan Note This means the configuration process has failed Three Short low beeps Slow blink Amber once every 25 sec Low Battery in the Bluetooth Module Four Short high beeps Off Suspend or O...

Page 27: ... trigger or press it for less than 30 seconds The previously stored configuration parameters are restored Reset Remove the battery Replace the battery while pressing the ring scanner trigger for 30 or more seconds The factory default configuration is restored Battery The 3 7V 750mAhH Li Ion battery in the Bluetooth module is designed to power the Bluetooth module for 8 hours and remain in standby ...

Page 28: ...s be performed on a clean well lit surface When necessary protect the work surface the mobile device and components from electrostatic discharge A 20 pak of full Trigger assemblies is available from LXE 8600A403TRIGGERKIT See Accessories Remove Finger Strap Assembly Fold the flexible liner back until the screw hole is visible 1 Rotate the trigger module until the black screw is visible as shown in...

Page 29: ... daily removal A 20 pak of Ring Scanner Finger Straps is available from LXE 8600A401RINGSTRAP See Accessories Using the Quick Disconnect Function grasp the finger strap and pull the finger strap out and away from the ring scanner Before attaching the finger strap to the trigger module thread the finger strap warning label side down first through the hinge then under and over the pin next to the sc...

Page 30: ...er cable 3 Connect the USB end of the firmware update cable to a PC and then insert the I O end of the firmware update cable in the I O connector on the Bluetooth module 4 Insert a fully charged battery pack into the Bluetooth Module The module powers up multiple beeps and the blue LED begins flashing 5 Bluetooth Module Firmware Update is ready to begin 6 Click Start All Programs and start the Blu...

Page 31: ... 14 Remove the firmware update cable from the I O port 15 At this point the PC is ready to upgrade the next Bluetooth module if desired Troubleshooting If the firmware update is interrupted due to loss of power or by removing the cable before the update is complete the original firmware will be destroyed and the Bluetooth Ring Scanner will not be able to run in normal operation mode If this event ...

Page 32: ...ameter you want to scan If this guide is in print form 3 lay this reference guide flat on a table or propped up at an angle 2 Holding the beam aperture approximately 2 12 inches away from the barcode aim the scan aperture toward the selected barcode See the scanner engine Decode Zones in Chapter 5 3 Press the Scan button Align the scan beam so that the barcode is centered within the beam The beam ...

Page 33: ... the Bluetooth module beeps indicating a successful scan The laser and scan On indicator automatically turn off after a successful or unsuccessful read The scanner is ready to scan again Note Whether there are beeps in conjunction with scan and decode functions is dependent on the application currently running in the LXE Bluetooth capable mobile device Beeps are emitted by the Bluetooth module not...

Page 34: ...ed by the Bluetooth Ring Scanner Module Beep After Good Decode Audible scan progress indicators are generated by the scanner driver on LXE mobile devices i e HX2 not the tethered ring decoder engine Use the Windows CE Control Panel options to set up the mobile device audible indicators Beeper Frequency Adjustment Audible scan progress indicators are generated by the scanner driver on LXE mobile de...

Page 35: ...ck into the scan aperture and possibly prevent a successful decode Barcode Symbology Barcodes such as UPC codes and Code 128 are more complex than Code 39 and Interleaved 2 of 5 When attempting to get the maximum read distance possible particularly with reflective labels use Code 39 The use of Code 128 or other more complex symbologies will almost always result in a reduction in maximum read dista...

Page 36: ...rinters Identify the scanner you wish to pair with by matching the Friendly name LXE Scanner MAC ID with the MAC address label on the scanner Doubletap the Friendly Name and select Pair as Scanner from the drop down menu Close the LXEZ Pairing application Notes Assumption is that the Bluetooth scanner parameters are at the factory defaults for the scanner When users can use any mobile device with ...

Page 37: ...ndheld or vehicle mount unit access the LXEZ Pairing control panel by tapping the Bluetooth icon on the Desktop or the Taskbar or the Control Panel Open the Bluetooth Devices panel Locate the Bluetooth Ring Scanner module in the list of paired devices by comparing the MAC ID number in the list with the MAC ID barcode on the module Doubletap the Bluetooth Ring Scanner module icon The right mouse cl...

Page 38: ... Imager 1 85oz 52 4g Environmental Operating Temperature 4 F to 122 F 20 C to 50 C Storage Temperature 40 F to 158 F 40 C to 60 C Water and Dust Resistance Sealed to IP 54 specifications or better Humidity 5 to 95 relative humidity non condensing Corrosion Corrosion resistant when exposed to water and common cleaning chemicals Chemical Resistance Corrosion resistant when exposed to water and commo...

Page 39: ...mware Update 8650A051CBLBTUPDATE Radio Bluetooth Back Of Hand Module 8650A276BTBOHMOD Battery Bluetooth Module 8650A376BTBOHBATTERY Charger 8 Bay Bluetooth Module US 8650A377BTBOHCHGRUS Charger 8 Bay Bluetooth Module WW 8650A378BTBOHCHGRWW Charger 1 Bay Bluetooth Module US 8650A379SINGLECHGRUS Charger 1 Bay Bluetooth Module WW 8650A380SINGLECHGRWW Strap Bluetooth Module Large Hand 8650A401LARGEBTS...

Page 40: ...28 Introduction Bluetooth Ring Scanner Guide E SW BLUESCANPG B ...

Page 41: ...uetooth Module before inserting a battery into the module The Bluetooth Module performs initialization with the Ring Scanner on bootup Fully charged battery must be secured in battery well Ring scanner or ring imager can be tethered to the Bluetooth module Both ring devices can read the LXE programming barcodes in this chapter If desired review the previous sections titled How To and Troubleshooti...

Page 42: ...LXE Scanner Module MAC address Ring Imager Focus Mode Smart Focus Volume High Restore Factory Defaults Scan this barcode to restore factory defaults in the Bluetooth Ring Scanner module Restore Factory Defaults Module Firmware Version Prerequisite Bluetooth Ring Scanner module is fully assembled battery ring decoder and connected to a device with a video display Scan this barcode with either the r...

Page 43: ...t every 1 second Enable Slave Mode Enable Pair as Master SAMPLE LnkB BARCODE DO NOT SCAN LnkB00440fd01020 Sample Scan the LnkB barcode on the LXE Bluetooth capable mobile device e g MX8 and the Bluetooth module is set to Master Mode Slave mode is disabled Note If the LnkB barcode is missing from the LXE Bluetooth capable mobile device contact your LXE representative Refer to the device specific re...

Page 44: ...out can be adjusted by scanning the following barcodes A trigger pull is required to wake the module from Suspend Note After the trigger pull to wake the module from Suspend another trigger pull is needed to scan a barcode Disable Suspend Timeout Set Suspend Timeout to 15 seconds Set Suspend Timeout to 30 seconds Set Suspend Timeout to 1 minute Set Suspend Timeout to 5 minutes ...

Page 45: ... Module Programming Barcodes 33 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Set Suspend Timeout 15 minutes Set Suspend Timeout to 30 minutes Set Suspend Timeout to 45 minutes Set Suspend Timeout to 60 minutes ...

Page 46: ...a short high beep and the Blue LED blinks slowly every 4 seconds When Beep on Reconnect is disabled and reconnect is unsuccessful over the reconnect interval the module emits a pattern of a short high beep and a short low beep and the blue LED blinks fast every 1 second Scan the Disable Beep on Reconnect to disable audible notification for connect and disconnect See Also Reconnect Interval Timeout...

Page 47: ... one of the following barcodes to set the interval of time between attempts to reconnect with a previously connected Bluetooth enabled device See Also Beep on Reconnect Reconnect Interval Timeout 15 seconds Reconnect Interval Timeout 30 seconds Reconnect Interval Timeout 45 seconds Reconnect Interval Timeout 1 minutes Reconnect Interval Timeout 5 minutes ...

Page 48: ...36 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Reconnect Interval Timeout 10 minutes Reconnect Interval Timeout 15 minutes Reconnect Interval Timeout 30 minutes ...

Page 49: ...ng barcodes to set the amount of time the Master device will retry connection attempts before ceasing attempts When the parameter is set to Off reconnect attempts will continue until the battery in the Bluetooth module is depleted See Also Beep on Reconnect Reconnect Timeout Off Reconnect Timeout 1 minute Reconnect Timeout 5 minutes Reconnect Timeout 30 minutes ...

Page 50: ...hing Parameter Default Value Enable When Role Switching is enabled and the module has successfully paired with an LXE Bluetooth capable mobile device e g MX8 as a master the module will perform role switching with the mobile device and become a slave device See Also Enable Slave Mode Enable Role Switching Disable Role Switching ...

Page 51: ...evice can connect to the Bluetooth Ring Scanner module When Authentication is enabled the connecting device is required to enter the PIN value set by the Bluetooth Ring Scanner module before successful connection can occur See Also Set PIN Code and PIN Code Default Enable Authentication Disable Authentication Encryption Parameter Default Value Encryption Disabled Encryption is the process of encod...

Page 52: ... reverts to the default setting after a module Reset holding the imager trigger for 30 seconds after reinstalling the module battery It reverts to the default setting after the Factory Defaults barcode is scanned When this Imager White LEDs parameter is not scanned but the Decoding Illumination parameter in Chapter 4 SE4400 Imager Barcodes is scanned the Imager White LEDs setting reverts to Disabl...

Page 53: ...odes 41 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Beep Volume Parameter Default Value High The Bluetooth Module speaker volume can be reset by scanning one of the following barcodes Volume Off Volume Low Volume Medium Volume High ...

Page 54: ...om the module as Smart Focus toggles after every frame Refer to the SE4400 Laser Imager section in Chapter 5 Scan Engine Technical Specifications for typical working ranges for the Ring Imager decoder The focus mode persists over a power cycle remove and replace the module battery This parameter reverts to the default setting after a module Reset holding the imager trigger for 30 seconds after rei...

Page 55: ...e Scan the numbers lowercase alpha and uppercase alpha barcodes that immediately follow this section When finished entering all characters scan the Stop PIN Code setup barcode Scan the Stop PIN Code setup barcode to end PIN Code data entry The PIN Code default value is 16 zeros To reset the Pin Code back to the default scan the Set Pin Code barcode and the Pin Code Default barcode only Set PIN Cod...

Page 56: ...y Name Scan the numbers lowercase alpha and uppercase alpha barcodes that immediately follow this section When finished entering all characters scan the Stop Friendly Name setup barcode to end Friendly Name data entry The Friendly Name default value is LXE Scanner MAC address in Hexadecimal The Friendly Name can be viewed using LXEZ Pairing on the paired LXE mobile device Set Friendly Name Stop Fr...

Page 57: ...Bluetooth Module Programming Barcodes 45 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Numbers Cancel current programming function 0 1 2 3 ...

Page 58: ...46 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B 4 5 6 7 ...

Page 59: ...Bluetooth Module Programming Barcodes 47 E SW BLUESCANPG B Bluetooth Ring Scanner Guide 8 9 Lowercase Letters Cancel current programming function a ...

Page 60: ...48 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B b c d e f ...

Page 61: ...Bluetooth Module Programming Barcodes 49 E SW BLUESCANPG B Bluetooth Ring Scanner Guide g h i j k ...

Page 62: ...50 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B l m n o p ...

Page 63: ...Bluetooth Module Programming Barcodes 51 E SW BLUESCANPG B Bluetooth Ring Scanner Guide q r s t u ...

Page 64: ...52 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B v w x y z ...

Page 65: ...Bluetooth Module Programming Barcodes 53 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Uppercase Letters Cancel current programming function A B C D ...

Page 66: ...54 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B E F G H I ...

Page 67: ...Bluetooth Module Programming Barcodes 55 E SW BLUESCANPG B Bluetooth Ring Scanner Guide J K L M N ...

Page 68: ...56 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B O P Q R S ...

Page 69: ...Bluetooth Module Programming Barcodes 57 E SW BLUESCANPG B Bluetooth Ring Scanner Guide T U V W X ...

Page 70: ...58 Bluetooth Module Programming Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Y Z ...

Page 71: ...e barcode in this chapter The new value replaces the standard default value in memory The following barcode symbologies are supported Symbology Default Setting Chinese 2 of 5 Disabled Codabar Disabled Code 11 Disabled Code 128 Enabled Code 39 Enabled Code 93 Disabled Discrete 2 of 5 Disabled Interleaved 2 of 5 Enabled MSI Plessey Disabled GS1 DataBar RSS Disabled UPC EAN UPC A UPC E UPC E1 EAN 8 E...

Page 72: ...ngines in this guide only This scan engine can have it s aiming beam aiming dot setup using these barcodes in this guide Use Laser On Time Aim Duration and Scan Angle How to get an aiming dot when there is no Aiming Dot parameter Set Aim Duration to 5 seconds and an aiming dot is sent while the scan trigger is held down When the timer expires the aiming beam widens and the barcode is read Prefix S...

Page 73: ...Raster Height Not Supported Scan Angle Clipping Not Supported Scan Angle Wide Scanning Mode Not Supported Time Delay to Low Power Not Supported Time out Between Different Symbols Not Supported Time out Between Same Symbol Not Supported Transmit No Read Message Disable Trigger Mode Host UPC EAN UPC A Enable UPC E Enable UPC E1 Disable EAN 8 Enable EAN 13 Enable Bookland EAN Disable Decode UPC EAN S...

Page 74: ...ble ISBT 128 Enable Code 128 Decode Performance Not Supported Code 128 Decode Performance Level Not Supported Code 39 Code 39 Enable Trioptic Code 39 Disable Convert Code 39 to Code 32 Disable Code 32 Prefix Disable Set Length s for Code 39 Length within Range 02 55 Code 39 Check Digit Verification Disable Transmit Code 39 Check Digit Disable Code 39 Full ASCII Conversion Disable Code 39 Decode Pe...

Page 75: ... Codabar Disable NOTIS Editing Disable Set Lengths for Codabar Length within Range 05 55 MSI Plessey MSI Plessey Disable Set Length s for MSI Plessey Length within Range 06 55 MSI Plessey Check Digits One Transmit MSI Plessey Check Digit Disable MSI Plessey Check Digit Algorithm Mod 10 Mod 10 PDF417 MicroPDF417 PDF417 Not Supported MicroPDF417 Not Supported Decode Linked Symbol Not Supported Code ...

Page 76: ...acter Delay 0 Host Serial Response Time out 2 sec Host Character Time out 200 msec Macro PDF Macro PDF Transmit Decode Mode Not Supported Transmit Each Symbol in Codeword Format Not Supported Transmit Unknown Codewords Not Supported Escape Character Not Supported ECI Delete Character Set ECIs Not Supported ECI Decoder Not Supported Transmit Macro PDF User Selected Field Transmit File Name Not Supp...

Page 77: ...CANPG B Bluetooth Ring Scanner Guide SE955 Parameter Default Flush Macro Buffer Not Supported Abort Macro PDF Entry Not Supported Beep on BEL This parameter is enabled There is no corresponding laser scanner programming barcode required ...

Page 78: ...ts scan Restore Defaults to retrieve and restore the scanner s custom default settings If no custom defaults were set scan Restore Defaults to restore the factory default values Set Factory Defaults Restore the factory default values If custom defaults were set they are eliminated Write Custom Defaults Store the current scanner settings as custom defaults Once custom default settings are stored th...

Page 79: ... barcode type on or off See also the barcode type s main section in this chapter For example see section UPC EAN for the remainder of the UPC EAN parameters such as UPC A Preamble UPC EAN Security Level etc Note Improve decode speed by disabling unused barcode types Bookland EAN Enable Bookland EAN Disable Bookland EAN Chinese 2 of 5 Enable Chinese 2 of 5 Disable Chinese 2 of 5 ...

Page 80: ...68 SE955 Laser Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Codabar Enable Codabar Disable Codabar Code 11 Enable Code 11 Disable Code 11 Code 128 Enable Code 128 Disable Code 128 ...

Page 81: ... Guide Code 39 Enable Code 39 Disable Code 39 Note Trioptic Code 39 symbols always contain 6 characters Trioptic Code and Code 39 Full ASCII should not be enabled simultaneously Enable Trioptic Code 39 Disable Trioptic Code 39 Code 93 Enable Code 93 Disable Code 93 ...

Page 82: ...70 SE955 Laser Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Discrete 2 of 5 Enable Discrete 2 of 5 Disable Discrete 2 of 5 EAN 13 Enable EAN 13 Disable EAN 13 EAN 8 Enable EAN 8 Disable EAN 8 ...

Page 83: ...des 71 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ISBT 128 Enable ISBT 128 Disable ISBT 128 MSI Plessey Enable MSI Plessey Disable MSI Plessey ...

Page 84: ...72 SE955 Laser Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B UCC EAN 128 Enable UCC EAN 128 Disable UCC EAN 128 UPC A Enable UPC A Disable UPC A UPC E Enable UPC E Disable UPC E ...

Page 85: ...SE955 Laser Barcodes 73 E SW BLUESCANPG B Bluetooth Ring Scanner Guide UPC E1 Enable UPC E1 Disable UPC E1 ...

Page 86: ...efore a scan attempt begins It does not apply to the aim signal or the Aim_On command It is programmable in 0 1 second increments from 0 0 to 9 9 seconds No aim pattern is visible when the value is 0 0 To set aim duration scan the barcode below Next scan two numeric barcodes that correspond to the desired aim duration Times less than 1 0 second must have a leading zero For example to set an aim du...

Page 87: ...essfully scanned in both directions before being decoded Note This parameter is only valid when a Linear Code Type Security Level has been enabled The default for Security Level parameter is Level 1 Select an option by scanning either of the barcodes shown below If you wish to change your selection scan Cancel Enable Bi Directional Redundancy Disable Bi Directional Redundancy Cancel ...

Page 88: ...values A prefix and or one or two suffixes may be appended to scan data for use in data editing These values are set by scanning four barcodes resulting in a four digit number that correspond to key codes for various mobile devices See the table titled ASCII Character Equivalents at the end of the Appendix for keycodes If you wish to change your selection scan this Data Format Cancel barcode Prefi...

Page 89: ... Keypad Number Symbols at the end of this chapter If you wish to change your selection scan Cancel on the Keypad Number Symbols page Suffix 2 To begin setting Suffix 2 value scan this barcode Next scan four numeric barcodes that correspond to the computer keycode using the Keypad Number Symbols at the end of this chapter If you wish to change your numeric selection scan Cancel on the Keypad Number...

Page 90: ... Data As Is Note Parameter Prefix Suffix Values should be set after setting this parameter Use this option when you want to append a prefix and suffix to the decode data Set this parameter by scanning one of the following barcodes Data As Is Data Suffix 1 Data Suffix 2 Data Suffix 1 Suffix 2 Prefix Data Prefix Data Suffix 1 ...

Page 91: ...SE955 Laser Barcodes 79 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Prefix Data Suffix 2 Prefix Data Suffix 1 Suffix 2 Cancel Now you are ready to scan one of the Prefix Suffix Values barcodes ...

Page 92: ...the prefix and the decoded symbol Scan one of the following barcodes to select either no code ID character a Symbol Code ID character or an AIM Code ID character Transmit No Code ID Character Transmit Symbol Code ID Character A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 ISBT 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J MSI Ple...

Page 93: ...er 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character conversion and checked one check character 7 Reader has performed Full ASCII character conversion and checked and stripped check character Example A Full ASCII barcode with check character W A I MI DW is transmitted as A7AimId where 7 3 4 Trioptic ...

Page 94: ...k digits verified and stripped before transmission Example An MSI Plessey barcode 4123 with a single check digit checked is transmitted as M04123 Discrete 2 of 5 0 No options specified at this time Always transmit 0 Example A D 2 of 5 barcode 4123 is transmitted as S04123 UPC EAN 0 Standard packet in full EAN country code format which is 13 digits for UPC A and UPC E not including supplemental dat...

Page 95: ...e in 0 1 second increments from 0 5 to 9 9 seconds If a label has not been decoded before this time expires and the session is terminated the system regards it as a failed scan attempt To begin setting Laser On Time scan this barcode Next scan two numeric barcodes that correspond to the desired on time using the Keypad Number Symbols at the end of this chapter Times less than 1 0 second must have ...

Page 96: ...er security levels are selected for decreasing levels of barcode quality As security levels increase the scanner s aggressiveness decreases Select an option by scanning one of the barcodes shown below If you wish to change your selection scan Cancel Linear Security Level 1 The following code types must be successfully read twice before being decoded Codabar All lengths MSI Plessey Length of 4 char...

Page 97: ...uccessfully read two times before being decoded The following codes Code 128 exception must be read three times MSI Plessey Length of 4 characters or less D 2 of 5 Length of 8 characters or less I 2 of 5 Length of 8 characters or less Level 4 All code types Code 128 exception must be successfully read three times before being decoded Cancel ...

Page 98: ...e Set Defaults parameter barcode to enable parameter scanning When disabled either scan the Enable Parameter Scanning barcode or the Set All Defaults barcode or set this parameter to 01h via a serial command to reset the parameter and barcodes in this chapter can then be scanned When enabled scanners can be configured using the barcodes in this chapter Select a mode by scanning either of the barco...

Page 99: ...lue Low Power A parameter setting of Continuous On means the laser scanner will not power down until the mobile device is powered off A parameter setting of Low Power means the laser scanner will enter low power mode after one second of waiting for a Scan button press Pressing the Scan button will begin the decode sequence Select a Power Mode by scanning either of the barcodes shown below Continuo...

Page 100: ...oose one of the options below to set the scan angle to narrow or wide The scan angle can be selected through scanning a parameter barcode Once the parameter barcode is scanned the Scan Angle setting is persistently stored Select an option by scanning one of the barcodes shown below Narrow Angle 35 Wide Scan Angle Cancel ...

Page 101: ...tings If no custom defaults were set scan Restore Defaults to restore the factory default values Set Factory Defaults Restore the factory default values If custom defaults were set they are eliminated Write Custom Defaults Store the current scanner settings as custom defaults Once custom default settings are stored they can be recovered at any time by scanning the Restore Defaults barcode Restore ...

Page 102: ... scanner interface programs for different hosts Contact LXE Customer Service for further assistance Default Values Option Default Baud Rate Not Supported Beep on BEL Not Supported Check Parity Not Supported Decode Data Packet Format Unpacketed Host Character Time out 200 msec Host Serial Response Time out 2 sec Intercharacter Delay 0 Parity None Software Handshaking Enable Stop Bit Select 1 ...

Page 103: ...is parameter selects whether decoded data is transmitted in raw format unpacketed or transmitted with the packet format as defined by the serial protocol If the raw format is chosen ACK NAK handshaking is automatically disabled for decode data Set this parameter by scanning either of the following barcodes Send Raw Decode Data Send Packeted Decode Data ...

Page 104: ...onds to 0 99 seconds After scanning the barcode below scan two numerical barcodes to set the desired time out To begin setting the time out value scan this barcode Next scan two numeric barcodes that correspond to the desired value using the Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero For example a value of 300 msec is selected by scanning the 3 a...

Page 105: ...ing the 4 and the 5 numeric barcodes A value of 0 3 seconds is selected by scanning the 0 and the 3 barcodes If you wish to change your selection scan Cancel on the Keypad Number Symbols page Intercharacter Delay Intercharacter Delay Parameter Default Value 0 msec Select the intercharacter delay option matching host requirements The intercharacter delay gives the host system time to service its re...

Page 106: ...t this parameter by scanning one of the following barcodes Odd Parity The Odd parity bit has a value 0 or 1 based on data to ensure that an odd number of 1 bits is contained in the coded character Even Parity The Even parity bit has a value 0 or 1 based on data to ensure that an even number of 1 bits is contained in the coded character Mark Parity The parity bit is always 1 Space Parity The parity...

Page 107: ...andshaking When this option is selected the decoder will neither generate nor expect ACK NAK handshaking packets Enable ACK NAK Handshaking When this option is selected after transmitting data the scanner expects either an ACK or NAK response from the host The scanner will also ACK or NAK messages from the host when this option is selected The scanner waits up to the programmable Host Serial Respo...

Page 108: ...end of transmission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving computer is programmed to accommodate Set the number of stop bits to match host device requirements Set this parameter by scanning one of the following barcodes One Stop Bit Two Stop Bits ...

Page 109: ...ctivates the laser and decode processing the processing continues until a trigger release or The laser decode processing continues until the Laser On Timeout is reached A NR No Read is transmitted to the host Any prefix or suffixes which have been enabled are appended around this message When disabled and a symbol does not decode no message is sent to the host Select an option by scanning either o...

Page 110: ...opriate barcode If you wish to change your selection scan Cancel Level A Scan button press activates the laser and decode processing The laser remains on and decode processing continues until a trigger release a valid decode or the Laser On Time out is reached Pulse A Scan button press activates the laser and decode processing The laser remains on and decode processing continues until a valid deco...

Page 111: ...Barcodes 99 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Host Triggering signal comes from a host command Any actual Scan button press will be interpreted by the scanner engine as a Level triggering option Cancel ...

Page 112: ... Chinese 2 of 5 symbols will be scanned decoded and transmitted Set this parameter by scanning either of the barcodes shown below Enable Chinese 2 of 5 Disable Chinese 2 of 5 Codabar Parameter Default Value Disable When enabled Codabar symbols will be scanned decoded and transmitted Set this parameter by scanning either of the barcodes shown below Enable Codabar Disable Codabar ...

Page 113: ...cters of a 14 character Codabar symbol Set this parameter by scanning either of the barcodes shown below Note Symbol length does not include start and stop characters Enable CLSI Editing Disable CLSI Editing NOTIS Editing Parameter Default Value Disable When enabled the start and stop characters are stripped from a decoded Codabar symbol Set this parameter by scanning either of the barcodes shown ...

Page 114: ...led ASCII Character Equivalents at the end of the Appendix One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Codabar symbols containing 14 characters scan the Codabar One Discrete Length barcode and then 1 and 4 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting one discrete le...

Page 115: ...to change your number selection scan Cancel on the Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Codabar symbols containing between 4 and 12 characters scan the Codabar Length Within Range barcode and then 0 4 1 and 2 barcodes To begin setting lengths within a range scan this barcod...

Page 116: ...low Enable Code 11 Disable Code 11 Set Lengths for Code 11 L1 Parameter Default Value 4 L2 Parameter Default Value 55 Lengths for Code 11 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains It also includes any start or stop characters See the table titled ASCII Cha...

Page 117: ...aining 2 or 14 characters scan the Code 11 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting two discrete lengths scan this barcode Next scan four numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypa...

Page 118: ...11 Check Digit Verification Parameter Default Value Disable When enabled this parameter checks the integrity of a Code 11 symbol to ensure it complies with the specified check digit algorithm Note Enable Code 11 Check Digit Verification when Transmit Code 11 Check Digits is enabled Set this parameter by scanning one of the barcodes shown below Disable this feature One Check Digit Two Check Digits ...

Page 119: ...ANPG B Bluetooth Ring Scanner Guide Transmit Code 11 Check Digits Parameter Default Value Do Not Transmit Disable Note Code 11 Check Digit Verification must be enabled for this parameter to function Transmit Enable Do Not Transmit Disable ...

Page 120: ...ard Code 128 barcode symbols UCC EAN 128 symbols are distinguished by a leading Function Code 1 FNC1 character as the first or second character in the symbol Other FNC1 characters are used to delineate fields When EAN 128 symbols are read they are transmitted after special formatting strips off the leading FNC1 character and replaces other FNC1 characters with the ASCII 29 GS control character Whe...

Page 121: ...28 Effect and Example Disable Disable No Code 128 symbols can be read Disable Enable Read only symbols with leading FNC1 Examples FNC1 ABCDFNC1 E are read as ABCD29 E AFNC1 BCDFNC1 E are read as ABCD29 E FNC1FNC1 ABCDFNC1 E are read as ABCD29 E ABCDFNC1 E cannot be read ABCDE cannot be read Enable Disable Read only symbols without leading FNC1 Examples FNC1 ABCDFNC1 E cannot be read AFNC1 BCDFNC1 ...

Page 122: ... E SW BLUESCANPG B ISBT 128 Parameter Default Value Enable Set this parameter by scanning either of the barcodes shown below Enable ISBT 128 Disable ISBT 128 Lengths for Code 128 No length setting is required for Code 128 The default setting is Any Length ...

Page 123: ...able Code 39 Disable Code 39 Code 39 Check Digit Verification Parameter Default Value Disable When enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled Set this parameter by scanning either of the barcodes shown below Enable Code 39 ...

Page 124: ...scanning either of the barcodes shown below Enable Code 32 Prefix Disable Code 32 Prefix Convert Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to function Parameter Default Value Disable Note When parameter Code 32 Prefix is to be enabled this Convert Code 39 to Code 32 Italian Pharma Code parameter must also be enabled Set this parameter by scanning either of the bar...

Page 125: ...odes are non printable and are assigned to keyboard control characters such as Backspace and Return or Enter The other 96 are called printable codes because all but Space and Delete produce visible characters Code 39 Full ASCII interprets the barcode special character preceding a Code 39 character and assigns an ASCII character value to the pair See the table titled ASCII Character Equivalents at ...

Page 126: ...ptions See the table titled ASCII Character Equivalents at the end of the Appendix One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Code 39 symbols containing 14 characters scan the Code 39 One Discrete Length barcode and then 1 and 4 barcodes using the Keypad Number Symbols at the end of this chapter To begin...

Page 127: ...to change your number selection scan Cancel on the Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Code 39 symbols containing between 4 and 12 characters scan the Code 39 Length Within Range barcode and then 0 4 1 and 2 barcodes using the Keypad Number Symbols at the end of this chapt...

Page 128: ... Parameter Default Value Disable When enabled the check digit is transmitted with the data Parameter setting for Code 39 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the barcodes shown below Enable Transmit Code 39 Check Digit Disable Transmit ...

Page 129: ... Disable Trioptic Code 39 symbols always contain six characters When Trioptic Code 39 is enabled set the Code 39 Full ASCII parameter to disabled Both parameters should not be enabled simultaneously Set this parameter by scanning either of the barcodes shown below Enable Trioptic Code 39 Disable Trioptic Code 39 ...

Page 130: ...f the barcodes shown below Enable Code 93 Disable Code 93 Set Lengths for Code 93 L1 Parameter Default Value 4 L2 Parameter Default Value 55 Lengths for Code 93 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains See the table titled ASCII Character Equivalents at t...

Page 131: ...digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only Code 93 symbols containing 2 or 14 characters scan the Code 93 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using t...

Page 132: ... Within Range barcode and then 0 4 1 and 2 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Any Length This option decodes ...

Page 133: ...Scanner Guide Discrete 2 of 5 Parameter Default Value Disable When enabled Discrete 2 of 5 D 2 of 5 symbols will be scanned decoded and transmitted Set this parameter by scanning either of the barcodes shown below Enable Discrete 2 of 5 Disable Discrete 2 of 5 ...

Page 134: ...arcodes using the Keypad Number Symbols at the end of this chapter To begin setting one discrete length scan this barcode Next scan two numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes con...

Page 135: ... 1 and 2 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Any Length This option decodes D 2 of 5 barcodes containing any n...

Page 136: ...CANPG B Interleaved 2 of 5 Parameter Default Value Enable When enabled Interleaved 2 of 5 I 2 of 5 symbols will be scanned decoded and transmitted Set this parameter by scanning either of the barcodes shown below Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ...

Page 137: ...enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm either USS Uniform Symbology Specification or OPCC Optical Product Code Council Set this parameter by scanning one of the barcodes shown below Disable I 2 of 5 Check Digit Verification USS Check Digit OPCC Check Digit Cancel ...

Page 138: ...rleaved 2 of 5 scanning is enabled One of the I 2 of 5 lengths is set to 14 The barcode has a leading zero The barcode has a valid EAN 13 check digit When enabled the parameter converts a 14 character I 2 of 5 barcode into EAN 13 and transmits it to the host as EAN 13 Set this parameter by scanning either of the barcodes shown below Enable Convert I 2 of 5 to EAN 13 Disable Convert I 2 of 5 to EAN...

Page 139: ...ivalents at the end of the Appendix One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only I 2 of 5 symbols containing 14 characters scan the I 2 of 5 One Discrete Length barcode and then 1 and 4 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting one discrete length scan this barcod...

Page 140: ...e Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only I 2 of 5 symbols containing between 4 and 12 characters scan the I 2 of 5 Length Within Range barcode and then 0 4 1 and 2 bar...

Page 141: ...for I 2 of 5 codes To set any length scan this barcode Transmit I 2 of 5 Check Digit Parameter Default Value Disable When enabled the check digit is transmitted with the data Parameter setting for I 2 of 5 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the barcodes shown below Enable Transmit I 2 of 5 Check Digit Disable Transmit I 2 of 5 Ch...

Page 142: ... scanning either of the barcodes shown below Enable MSI Disable MSI MSI Plessey Check Digit Algorithm Parameter Default Value Mod10 Mod10 When the Two MSI Plessey Check Digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms may be selected Set this parameter by scanning either of the algorithm barcodes shown below Mod 10 Mod 11 M...

Page 143: ...e integrity of the data At least one check digit is always required Check digits are not automatically transmitted with the data Note When Two Check Digits is selected an MSI Plessey Check Digit Algorithm must also be selected Set the number of check digits to be included with the barcode by scanning either of the barcodes shown below One MSI Plessey check digit Two MSI Plessey check digits ...

Page 144: ...arcodes using the Keypad Number Symbols at the end of this chapter To begin setting one discrete length scan this barcode Next scan two numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes con...

Page 145: ... 1 and 2 barcodes using the Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Any Length This option decodes MSI Plessey barcodes containing an...

Page 146: ...B Transmit MSI Plessey Check Digit Parameter Default Value Disable When enabled the check digit is transmitted with the data Set this parameter by scanning either of the barcodes shown below Enable Transmit MSI Plessey Check Digit Disable Transmit MSI Plessey Check Digit ...

Page 147: ...nner Guide UPC EAN UPC A Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable UPC A Disable UPC A UPC E Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable Disable ...

Page 148: ...ANPG B UPC E1 Parameter Default Value Disable Select an option by scanning either of the barcodes shown below Enable UPC E1 Disable UPC E1 EAN 8 Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable EAN 8 Disable EAN 8 ...

Page 149: ... 13 Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable EAN 13 Disable EAN 13 Bookland EAN Parameter Default Value Disable Select an option by scanning either of the barcodes shown below Enable Bookland EAN Disable Bookland EAN ...

Page 150: ...heck digit Select an option by scanning either of the barcodes shown below Enable Transmit UPC A Check Digit Disable Transmit UPC A Check Digit Transmit UPC E Check Digit Parameter Default Value Enable This parameter determines whether the symbol will be transmitted with or without the UPC E check digit Select an option by scanning either of the barcodes shown below Enable Transmit UPC E Check Dig...

Page 151: ... E1 Check Digit Parameter Default Value Enable This parameter determines whether the symbol will be transmitted with or without the UPC E1 check digit Select an option by scanning either of the barcodes shown below Enable Transmit UPC E1 Check Digit Disable Transmit UPC E1 Check Digit ...

Page 152: ...onversion Select an option by scanning either of the barcodes shown below Enable UPC E to UPC A conversion Disable UPC E to UPC A conversion Convert UPC E1 to UPC A Parameter Default Value Disable When this parameter is enabled UPC E1 zero suppressed decoded data is converted to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selecti...

Page 153: ...ue Type is EAN 13 When EAN 8 Zero Extend is enabled this parameter setting labels the extended symbol as either an EAN 13 barcode or an EAN 8 barcode When EAN 8 Zero Extend is disabled this parameter s conversion setting is ignored Select an option by scanning either of the barcodes shown below Type is EAN 13 Type is EAN 8 ...

Page 154: ...evice The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No UPC A Preamble DATA System Character SYSTEM CHARACTER DATA System Character and Country Code 0 for USA COUNTRY CODE SYSTE...

Page 155: ... The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No UPC E Preamble DATA System Character SYSTEM CHARACTER DATA System Character and Country Code 0 for USA COUNTRY CODE SYSTEM CHA...

Page 156: ...e The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No UPC E1 Preamble DATA System Character SYSTEM CHARACTER DATA System Character and Country Code 0 for USA COUNTRY CODE SYSTEM C...

Page 157: ...according to specific code format conventions e g UPC A 2 Select an option by scanning one of the barcodes shown below Decode UPC EAN with Supplementals UPC EAN symbols without supplemental characters are not decoded Ignore UPC EAN with Supplementals When a UPC EAN plus supplemental symbol is scanned the UPC EAN is decoded and the supplemental characters ignored Autodiscriminate UPC EAN Supplement...

Page 158: ...upplemental characters ignored Enable 978 Supplemental Mode The scanner will identify supplementals for EAN 13 barcodes that start with a 978 prefix only All other UPC EAN codes are decoded immediately and the supplemental characters ignored Enable Smart Supplemental Mode The scanner will identify supplementals for EAN 13 barcodes that start with a 378 379 or 978 prefix only All other UPC EAN code...

Page 159: ... Next scan two numeric barcodes that correspond to the desired value using the Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero If you wish to change your selection scan Cancel on the Keypad Number Symbols page EAN 8 Zero Extend Parameter Default Value Disable When this parameter is enabled five leading zeros are added to decoded EAN 8 symbols to make ...

Page 160: ...upon Extended Code replaces UPC EAN Coupon Code Parameter Default Value Disable The UCC Coupon Extended Code is an additional barcode adjacent to a UCC Coupon Code To enable or disable UCC Coupon Extended Code scan the appropriate barcode below Enable UCC Coupon Extended Code Disable UCC Coupon Extended Code ...

Page 161: ... scanner s aggressiveness decreases Select an option by scanning one of the barcodes shown below If you wish to change your selection scan Cancel UPC EAN Security Level 0 The default setting Allows the scanner to operate in its most aggressive state while providing sufficient security in decoding in spec UPC EAN barcodes Level 1 Mis decode 1 2 7 8 As barcode quality levels diminish certain charact...

Page 162: ...ou have tried security level 2 and are still experiencing mis decodes Using this level is an extreme measure against mis decoding severely out of spec barcodes This level significantly impairs the decoding ability of the scanner If this level of security is necessary you should try to improve the quality of your barcodes Cancel ...

Page 163: ...1 DataBar Omnidirectional RSS 14 Enable GS1 DataBar Omnidirectional RSS 14 Disable GS1 DataBar Omnidirectional RSS 14 GS1 DataBar Limited RSS Limited Enable GS1 DataBar Limited RSS Limited Disable GS1 DataBar Limited RSS Limited GS1 DataBar Expanded RSS Expanded Enable GS1 DataBar Expanded RSS Expanded Disable GS1 DataBar Expanded RSS Expanded ...

Page 164: ...ar Limited RSS Limited symbols encoding a single zero as the first digit have the leading 010 stripped and the barcode reported as EAN 13 Barcodes beginning with two or more zeros but not six zeros have the leading 0100 stripped and the barcode reported as UPC A The UPC A Preamble parameter to transmit the system character and country code applies to converted barcodes Note that neither the system...

Page 165: ...bols The barcode labels shown below represent a numeric keypad with decimal values 0 through 9 Each label can be scanned individually to enter a numeric value Use these numeric value symbols to enter numeric input in the course of performing a scan engine system configuration 0 1 2 3 4 5 6 ...

Page 166: ...154 SE955 Laser Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B 7 8 9 Cancel ...

Page 167: ...sentative To change a parameter value Scan the appropriate barcode in this chapter The new value replaces the standard default value in memory Note Using the imager like a camera or for OCR decoding is not supported in this release Symbology Default Setting Symbology Default Setting Codabar Disabled 2D Symbologies Code 11 Disabled PDF417 Enabled Code 128 Enabled MicroPDF Disabled Code 39 Enabled C...

Page 168: ...r Service for assistance Prefix Suffix SE4400 prefix and suffix parameters cannot be set changed or reset using the barcodes in this chapter Refer to the chapter titled Scanner in the device specific Reference Guide e g HX2 HX3 for information and instruction on setting up the following imager parameters Enable Disable decoding sounds Imager LED Illumination COM1 Serial Parameters Code ID AIM Symb...

Page 169: ...o barcode available Focus Mode Far Focus Decoding Autoexposure Enable Decoding Illumination Enable Decode Aiming Pattern Enable LED Illumination PL4407 Internal LED Illumination LED Illumination MS4407 External LED Illumination Miscellaneous Imager Options FN1 Substitution Values Not Supported Prefix Suffix Values Not Supported Scan Data Transmission Format Data As Is Transmit No Read Message Disa...

Page 170: ... Disable Code 93 Code 93 Disable Set Length s for Code 93 4 to 55 Code 11 Code 11 Disable Set Lengths for Code 11 4 to 55 Code 11 Check Digit Verification Disable Transmit Code 11 Check Digit s Disable Interleaved 2 of 5 ITF Interleaved 2 of 5 ITF Enable Set Lengths for I 2 of 5 14 I 2 of 5 Check Digit Verification Disable Transmit I 2 of 5 Check Digit Disable Convert I 2 of 5 to EAN 13 Disable Di...

Page 171: ...C EAN Code 128 Emulation Mode for UCC EAN Composite Codes Disable 2D Symbologies PDF417 Enable MicroPDF417 Disable Code 128 Emulation Disable Data Matrix Enable Data Matrix Inverse Regular Only Maxicode Enable QR Code Enable MicroQR Enable QR Inverse Regular Only Aztec Enable Aztec Inverse Regular Only Symbology Specific Security Levels Redundancy Level 1 Security Level 1 Intercharacter Gap Size N...

Page 172: ...erm settings Note When the Parameter Scanning parameter is disabled the scan engine can still scan the Set All Defaults barcode Default value of Parameter Scanning is Enable When parameters are changed the new value replaces the standard default value in memory Note After scanning Set All Defaults barcode reboot the Bluetooth Ring Scanner Module by removing the battery then reinserting the battery...

Page 173: ...in this chapter Note When this parameter is disabled scan the Set All Defaults parameter barcode to enable parameter scanning When disabled either scan the Enable Parameter Scanning barcode or the Set All Defaults barcode to reset the parameter When enabled scanners can be configured using the barcodes in this chapter Select a mode by scanning either of the barcodes shown below Enable Parameter Sc...

Page 174: ...arcode type s main section in this chapter For example see section UPC EAN for the remainder of the UPC EAN parameters such as UPC A Preamble UPC EAN Security Level etc Note Increase decode time by disabling unused barcode types 2D Symbologies Refer to this symbology s section later in this chapter for more programming barcodes PDF417 Enable PDF417 Disable PDF417 MicroPDF417 Enable MicroPDF417 Dis...

Page 175: ...odes 163 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Code 128 Emulation Enable Code 128 Emulation Disable Code 128 Emulation Data Matrix Enable Data Matrix Disable Data Matrix Maxicode Enable Maxicode Disable Maxicode ...

Page 176: ...ble QR Code Disable QR Code Codabar Refer to this symbology s main section later in this chapter for more programming barcodes Disable Codabar Enable Codabar Code 11 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Code 11 Disable Code 11 ...

Page 177: ...r Guide Code 39 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Code 39 Disable Code 39 Code 93 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Code 93 Disable Code 93 ...

Page 178: ...28 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Code 128 Disable Code 128 Composite Refer to this symbology s section later in this chapter for more programming barcodes Composite CC C Enable Composite CC C Disable Composite CC C ...

Page 179: ... CC A B Enable Composite CC A B Disable Composite CC A B Composite TLC 39 Enable Composite TLC 39 Disable Composite TLC 39 Interleaved 2 of 5 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ...

Page 180: ...ete 2 of 5 Refer to this symbology s main section later in this chapter for more programming barcodes Enable Discrete 2 of 5 Disable Discrete 2 of 5 ISBT 128 Refer to this symbology s main section later in this chapter for more programming barcodes Enable ISBT 128 Disable ISBT 128 ...

Page 181: ...lessey Code Refer to this symbology s main section later in this chapter for more programming barcodes Enable MSI Disable MSI Postal Codes Refer to this symbology category s section later in this chapter for more programming barcodes US Postnet Enable US Postnet Disable US Postnet ...

Page 182: ...00 Imager Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B US Planet Enable US Planet Disable US Planet UK Postal Enable UK Postal Disable UK Postal Japan Postal Enable Japan Postal Disable Japan Postal ...

Page 183: ...nable Australian Postal Disable Australian Postal Dutch Postal Enable Dutch Postal Disable Dutch Postal GS1 DataBar RSS Refer to this symbology s main section later in this chapter for more programming barcodes Enable GS1 DataBar Omnidirectional RSS 14 Disable GS1 DataBar Omnidirectional RSS 14 ...

Page 184: ... Ring Scanner Guide E SW BLUESCANPG B UPC EAN Refer to this symbology s main section later in this chapter for more programming barcodes UPC A Enable UPC A Disable UPC A UPC E Enable UPC E Disable UPC E UPC E1 Enable UPC E1 Disable UPC E1 ...

Page 185: ...codes 173 E SW BLUESCANPG B Bluetooth Ring Scanner Guide EAN 8 JAN 8 Enable EAN 8 JAN 8 Disable EAN 8 JAN 8 EAN 13 JAN 13 Enable EAN 13 JAN 13 Disable EAN 13 JAN 13 Bookland EAN Enable Bookland EAN Disable Bookland EAN ...

Page 186: ...Parameter Default Value 9 9 Seconds This parameter sets the maximum time decode processing continues during a scan attempt It is programmable in 0 1 second increments from 0 5 to 9 9 seconds If a label has not been decoded before this time expires and the session is terminated the software regards it as a failed scan attempt To begin setting a decode session time out in seconds scan this Decode Se...

Page 187: ...ng pattern off Enable Decode Aiming Pattern Disable Decode Aiming Pattern Decoding Autoexposure Parameter Default Value Enable Select Enable Autoexposure to allow the imager to control gain settings and exposure integration time to best capture an image for the selected operation mode Select Disable Autoexposure to manually adjust the gain and exposure time not supported in this version This optio...

Page 188: ...oder has three small bright LEDs situated above the scan aperture Enable this parameter for LED illumination upon every decode The effectiveness of the illumination decreases as the distance to the target increases Disable this parameter to prevent LED illumination See LED Illumination Select a setting by scanning one of the barcodes shown below If you wish to change your selection scan Cancel Ena...

Page 189: ...a focus mode to control the working range of the imager When Far Focus is selected the imager is optimized to read at its far position With Near Focus the imager is optimized to read at its near position Smart Focus toggles the focus position after every frame Scan the appropriate barcode below Far Focus Near Focus Smart Focus ...

Page 190: ...er has three small bright LEDs situated above the scan aperture Internal LED illumination turns the LEDs on during scan mode The effectiveness of the illumination decreases as the distance to the target increases External illumination setting turns the LEDs off during scan mode Internal and External Illumination turns the LEDs on during scan mode See Decoding Illumination Select an illumination se...

Page 191: ... activated and the image is captured as the decoder adjusts to the lighting conditions Hold the imager steady until the image is captured denoted by a single beep If a trigger event is not activated within the Snapshot Mode Timeout period the decoder returns to Decode Mode Use Snapshot Mode Timeout not supported in this version to adjust this timeout period The default timeout period is 30 seconds...

Page 192: ...er MS4407 Continuous On A parameter setting of Continuous On means the laser will not power down until the mobile device is powered off A parameter setting of Low Power means the laser will enter low power consumption mode after each decode attempt Pressing the Scan button will begin another decode sequence See Time Delay to Low Power Mode Select a Power Mode by scanning either of the barcodes sho...

Page 193: ...des that enter its field of view Presentation Mode applies to Decode Mode only See also Trigger Modes Parameter Default Value 2 Seconds To set the duration of the attempt to decode a barcode detected in presentation mode scan the Presentation Mode Session Timeout barcode below Next scan three numeric barcodes from Imager Keypad Number Symbols to select a value between 1 and 255 that represents ten...

Page 194: ...econd This parameter sets the time the decoder remains active after decoding The decoder wakes upon a Scan button press or when the host attempts to communicate with the decoder This parameter only applies when Power Mode is set to Low Power See Power Mode 1 Second Delay 5 Second Delay 1 Minute Delay 5 Minute Delay 15 Minute Delay ...

Page 195: ...hen the barcode is removed from the field of view It is programmable in 0 1 second increments from 0 0 to 9 9 seconds To select the timeout between decodes for the same symbol scan the following barcode then scan two numeric barcodes from the Imager Keypad Number Symbols at the end of this chapter that correspond to the desired interval in 0 1 second increments Times less than 1 0 second must have...

Page 196: ...ou wish to change your selection scan Cancel Level Trigger Mode A Scan button press activates the laser and decode processing The laser remains on and decode processing continues until a Scan button release a valid decode or the decode session time out is reached Presentation Trigger ModeWhen the ring scanner detects an object in its field of view it scans and attempts to decode The range of objec...

Page 197: ...odes 185 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Cancel See also Presentation Mode Session Timeout Report Version Scan the following barcode to view the version of software currently installed in the ring decoder ...

Page 198: ...acter a Symbol Code ID character or an AIM Code ID character Transmit No Code ID Character Transmit Symbol Code ID Character A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J MSI Plessey K UCC EAN 128 L Bookland EAN M Trioptic Code 39 N Coupon Code R GS1 DataBar Omnidirectional RSS 14 GS1 Da...

Page 199: ...stralian Postal Dutch Postal m Modifier Character The modifier character is the sum of the applicable option values based on the following table Code Type Option Value Option Code39 0 No Check character or Full ASCII processing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Ful...

Page 200: ...smitted as F04123 Code 93 0 No options specified at this time Always transmit 0 Example A Code 93 barcode 012345678905 is transmitted as G0012345678905 MSI Plessey 0 Single check digit checked 1 Two check digits checked 2 Single check digit verified and stripped before transmission 3 Two check digits verified and stripped before transmission Example An MSI Plessey barcode 4123 with a single check ...

Page 201: ...a packet containing the data following an escape mechanism character The data packet supports the ECI protocol UCC EAN 128 emulation Note UPC portion of composite is transmitted using UPC rules 1 Data packet is a UCC EAN 128 symbol i e data is preceded with JC1 PDF417 Micro PDF417 0 Reader set to conform to protocol defined in 1994 PDF417 symbology specifications Note When this option is transmitt...

Page 202: ...rotocol implemented 3 Symbol in Mode 2 or 3 ECI protocol implemented in secondary message QR Code 0 Model 1 symbol 1 Model 2 symbol ECI protocol not implemented 2 Model 2 symbol ECI protocol implemented 3 Model 2 symbol ECI protocol not implemented FNC1 implied in first position 4 Model 2 symbol ECI protocol implemented FNC1 implied in first position 5 Model 2 symbol ECI protocol not implemented F...

Page 203: ...canning four barcodes resulting in a four digit number that correspond to key codes for various mobile devices See the table titled ASCII Character Equivalents at the end of the Appendix for keycodes Prefix To begin setting Prefix values scan this Scan Prefix barcode Next scan four numeric barcodes that correspond to the computer keycode using the Imager Keypad Number Symbols at the end of this ch...

Page 204: ...n setting Suffix 2 value scan this Scan Suffix 2 barcode Next scan four numeric barcodes that correspond to the computer keycode using the Imager Keypad Number Symbols at the end of this chapter If you wish to change your numeric selection scan Cancel on the Imager Keypad Number Symbols page ...

Page 205: ... Values should be set after setting this parameter Use this option when you want to append a prefix and suffix to the decode data If you wish to change your selection scan the Cancel barcode and scan again Set the Scan Data Transmission Format parameter by scanning one of the following barcodes Data As Is Data Suffix 1 Data Suffix 2 Data Suffix 1 Suffix 2 Prefix Data ...

Page 206: ...0 Imager Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Prefix Data Suffix 1 Prefix Data Suffix 2 Prefix Data Suffix 1 Suffix 2 Cancel Now you are ready to scan one of the Prefix Suffix Values barcodes ...

Page 207: ...Message Parameter Default Value Disable Scan a barcode below to select whether or not to transmit a No Read message When enabled the characters NR are transmitted when a barcode is not decoded When disabled if a symbol does not decode nothing is sent to the host Enable No Read Disable No Read ...

Page 208: ...NPG B UPC EAN UPC A Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable UPC A Disable UPC A UPC E Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable UPC E Disable UPC E ...

Page 209: ...sable Select an option by scanning either of the barcodes shown below Enable UPC E1 Disable UPC E1 Note UPC E1 is not a UCC Uniform Code Council approved symbology EAN 8 JAN 8 Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable EAN 8 JAN 8 Disable EAN 8 JAN 8 ...

Page 210: ...mager Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B EAN 13 JAN 13 Parameter Default Value Enable Select an option by scanning either of the barcodes shown below Enable EAN 13 JAN 13 Disable EAN 13 JAN 13 ...

Page 211: ...ue Disable Select an option by scanning either of the barcodes shown below Enable Bookland EAN Disable Bookland EAN Bookland Format Parameter Default Value Bookland 10 This parameter is used to control the Bookland Format Select an option by scanning either of the barcodes shown below Bookland 10 Bookland 13 ...

Page 212: ... for EAN 13 JAN 13 barcodes that start with a 378 or 379 prefix only All other UPC EAN JAN codes are decoded immediately and the supplemental characters ignored Enable 978 Supplemental Mode The scanner will identify supplementals for EAN 13 JAN 13 barcodes that start with a 978 prefix only All other UPC EAN JAN codes are decoded immediately and the supplemental characters ignored Enable Smart Supp...

Page 213: ...Imager Barcodes 201 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Autodiscriminate UPC EAN JAN Supplementals Enable 378 379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mode Cancel ...

Page 214: ...nate option is selected To begin setting the decode redundancy value scan this barcode Next scan two numeric barcodes that correspond to the desired value using the Imager Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero To correct an error or change a selection scan Cancel on the Imager Keypad Number Symbols page Transmit UPC A Check Digit Parameter D...

Page 215: ...it Select an option by scanning either of the barcodes shown below Enable Transmit UPC E Check Digit Disable Transmit UPC E Check Digit Transmit UPC E1 Check Digit Parameter Default Value Enable This parameter determines whether the symbol will be transmitted with or without the UPC E1 check digit Select an option by scanning either of the barcodes shown below Enable Transmit UPC E1 Check Digit Di...

Page 216: ...bols transmitted to the host device The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No Preamble System Character System Character and Country Code 0 for USA ...

Page 217: ...bols transmitted to the host device The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No Preamble System Character System Character and Country Code 0 for USA ...

Page 218: ...mbols transmitted to the host device The lead in characters are considered part of the symbol Data is sent to the host in the following format No Preamble data System Character schar data System Character and Country Code country code schar data Select an option by scanning one of the barcodes shown below No Preamble System Character System Character and Country Code 0 for USA ...

Page 219: ...ssed decoded data is converted to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit etc When disabled UPC E zero suppressed decoded data is transmitted without conversion Select an option by scanning either of the barcodes shown below Enable UPC E to UPC A Disable UPC E to UPC A ...

Page 220: ...ssed decoded data is converted to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit etc When disabled UPC E1 zero suppressed decoded data is transmitted without conversion Select an option by scanning either of the barcodes shown below Enable UPC E1 to UPC A Disable UPC E1 to UPC A ...

Page 221: ...to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Use parameter Convert EAN 8 to EAN 13 Type to label the extended symbol When disabled EAN 8 symbols are transmitted as is and parameter Convert EAN 8 to EAN 13 Type setting is ignored Select an option by scanning either of the barcodes shown below Enable EAN 8 JAN 8 Zero Extend Disable EAN 8 JAN 8 Zero Extend ...

Page 222: ...or disable UCC Coupon Extended Code scan the appropriate barcode below When enabled this parameter decodes UPC A barcodes starting with digit 5 EAN 13 barcodes starting with digit 99 and UPC A EAN 128 Coupon Codes UPCA EAN 13 and EAN 128 must be enabled to scan all types of Coupon Codes Enable UCC Coupon Extended Code Disable UCC Coupon Extended Code Note Use the Decode UPC EAN Supplemental Redund...

Page 223: ...128 Parameter Default Value Enable Set this parameter by scanning either of the barcodes shown below Enable Code 128 Disable Code 128 UCC EAN 128 Parameter Default Value Enable Set this parameter by scanning either of the barcodes shown below Enable UCC EAN 128 Disable UCC EAN 128 ...

Page 224: ... B ISBT 128 Parameter Default Value Enable ISBT 128 is a variant of Code 128 used in the blood bank industry If necessary the host must perform concatenation of the ISBT data Set this parameter by scanning either of the barcodes shown below Enable ISBT 128 Disable ISBT 128 ...

Page 225: ...nning either of the barcodes shown below Enable Code 39 Disable Code 39 Trioptic Code 39 Parameter Default Value Disable Trioptic Code 39 symbols always contain six characters When Trioptic Code 39 is enabled set the Code 39 Full ASCII parameter to disabled Both parameters should not be enabled simultaneously Set this parameter by scanning either of the barcodes shown below Enable Trioptic Code 39...

Page 226: ...Italian Pharmacy Code parameter must also be enabled Set this parameter by scanning either of the barcodes shown below Enable Convert Code 39 to Code 32 Disable Convert Code 39 to Code 32 Code 32 Prefix Parameter Default Value Disable This parameter adds the prefix character A to all Code 32 barcodes Note When enabled Convert Code 39 to Code 32 parameter must also be enabled Set this parameter by ...

Page 227: ...ger Keypad Number Symbols at the end of this chapter Single digits must be preceded by a zero To begin setting one discrete length scan this One Discrete Length barcode Next scan two numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Length...

Page 228: ...and then 0 4 1 and 2 barcodes using the Imager Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this Length Within Range barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This op...

Page 229: ...cified check digit algorithms Only Code 39 symbols which include a Modulo 43 check digit are decoded when this parameter is enabled Note When Transmit Code 39 Check Digit is enabled this parameter must be enabled too Enable this feature if the code 39 barcodes contain a Modulo 43 check digit Set this parameter by scanning either of the barcodes shown below Enable Code 39 Check Digit Verification D...

Page 230: ...eck digit is transmitted with the data Note Code 39 Check Digit Verification must be enabled for this parameter to function Parameter setting for Code 39 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the barcodes shown below Enable Transmit Code 39 Check Digit Disable Transmit Code 39 Check Digit ...

Page 231: ...nversion Disable Code 39 Full ASCII Conversion When enabled the ASCII character set assigns a code to letters punctuation marks numerals and most control keystrokes on the keyboard The first 32 codes are non printable and are assigned to keyboard control characters such as Backspace and Return or Enter The other 96 are called printable codes because all but Space and Delete produce visible charact...

Page 232: ...his parameter by scanning either of the barcodes shown below Enable Code 93 Disable Code 93 Set Lengths for Code 93 L1 Parameter Default Value 4 L2 Parameter Default Value 55 Lengths for Code 93 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains See the table title...

Page 233: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only Code 93 symbols containing 2 or 14 characters scan the Code 93 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using ...

Page 234: ... 0 4 1 and 2 barcodes using the Imager Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this Code 93 Length Within Range barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This op...

Page 235: ...elow Enable Code 11 Disable Code 11 Set Lengths for Code 11 L1 Parameter Default Value 4 L2 Parameter Default Value 55 Lengths for Code 11 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains It also includes any start or stop characters See the table titled ASCII Ch...

Page 236: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only Code 11 symbols containing 2 or 14 characters scan the Code 11 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using ...

Page 237: ... 0 4 1 and 2 barcodes To begin setting lengths within a range scan this Code 11 Length Within Range barcode Next scan numeric barcodes that correspond to the desired value using the Imager Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This op...

Page 238: ... barcode or Two Check Digits barcode When enabled this parameter checks the integrity of a Code 11 symbol to ensure it complies with the specified check digit algorithm Note Enable Code 11 Check Digit Verification when Transmit Code 11 Check Digits is enabled Set this parameter by scanning one of the barcodes shown below Disable Code 11 Check Digit Verification One Check Digit Two Check Digits ...

Page 239: ...ing Scanner Guide Transmit Code 11 Check Digits Parameter Default Value Do Not Transmit Disable Code 11 Check Digit Verification must be enabled for this parameter to function Transmit Enable Code 11 Check Digits Do Not Transmit Disable Code 11 Check Digits ...

Page 240: ...f the barcodes shown below Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Lengths for I 2 of 5 L1 Parameter Default Value 14 L2 Parameter Default Value 14 Lengths for Interleaved 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains See the table titl...

Page 241: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only I 2 of 5 symbols containing 2 or 14 characters scan the I 2 of 5 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes usin...

Page 242: ...ger Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this I 2 of 5 Length within Range barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This option decodes I 2 of 5 barcodes con...

Page 243: ...s parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm either USS Uniform Symbology Specification or OPCC Optical Product Code Council Set this parameter by scanning one of the barcodes shown below Disable I 2 of 5 Check Digit Verification USS Uniform Symbology Specification OPCC Optical Product Code Council ...

Page 244: ... Default Value Disable When enabled the check digit is transmitted with the data Parameter setting for I 2 of 5 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the barcodes shown below Enable Transmit I 2 of 5 Check Digit Disable Transmit I 2 of 5 Check Digit ...

Page 245: ...erleaved 2 of 5 scanning is enabled One of the I 2 of 5 lengths is set to 14 The barcode has a leading zero The barcode has a valid EAN 13 check digit When enabled the parameter converts a 14 character I 2 of 5 barcode into EAN 13 and transmits it to the host as EAN 13 Set this parameter by scanning either of the barcodes shown below Enable Convert I 2 of 5 to EAN 13 Disable Convert I 2 of 5 to EA...

Page 246: ...ue 12 Lengths for D 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains Note Due to the construction of the D2 of 5 symbology it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is en...

Page 247: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only D 2 of 5 symbols containing 2 or 14 characters scan the D 2 of 5 Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes usin...

Page 248: ...ols at the end of this chapter To begin setting lengths within a range scan this D 2 of 5 Length Within Range barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This option decodes D 2 of 5 barcodes containing any number of ...

Page 249: ...rcodes shown below Enable Codabar Disable Codabar CLSI Editing Parameter Default Value Disable When enabled the start and stop characters are stripped from the barcode and a space is inserted after the 1st 5th and 10th characters of a 14 character Codabar symbol Set this parameter by scanning either of the barcodes shown below Note Symbol length does not include start and stop characters Enable CL...

Page 250: ...own below Enable NOTIS Editing Disable NOTIS Editing Set Lengths for Codabar L1 Parameter Default Value 5 L2 Parameter Default Value 55 Lengths for Codabar may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains It also includes any start or stop characters See the tabl...

Page 251: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only Codabar symbols containing 2 or 14 characters scan the Codabar Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using ...

Page 252: ...mager Keypad Number Symbols at the end of this chapter To begin setting lengths within a range scan this Codabar Length Within Range barcode Next scan numeric barcodes that correspond to the desired value using the Imager Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Numbe...

Page 253: ...ay be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains Note Due to the construction of the MSI symbology it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan yielding less data than is encoded in the barcode To prevent ...

Page 254: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only MSI symbols containing 2 or 14 characters scan the MSI Two Discrete Lengths barcode and then 0 2 1 and 4 barcodes using the Imag...

Page 255: ...ymbols at the end of this chapter To begin setting lengths within a range scan this MSI Length Within Range barcode Next scan numeric barcodes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This option decodes MSI barcodes containing any number of charact...

Page 256: ... If the MSI codes include two check digits scan the Two MSI Check Digits barcode to enable verification of the second check digit Check digits are not automatically transmitted with the data Note When Two MSI Check Digits is selected an MSI Check Digit Algorithm must also be selected Set the number of check digits to be included with the barcode by scanning either of the barcodes shown below One M...

Page 257: ... Scanner Guide Transmit MSI Check Digit Parameter Default Value Disable When enabled the check digit is transmitted with the data Set this parameter by scanning either of the barcodes shown below Enable Transmit MSI Check Digit Disable Transmit MSI Check Digit ...

Page 258: ...ptional If the MSI codes include two check digits scan the Two MSI Check Digits barcode to enable verification of the second check digit When the Two MSI Check Digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms may be selected Set this parameter by scanning either of the barcodes shown below Mod 10 Mod 11 MSI Check Digit Algo...

Page 259: ... Codes US Postnet Parameter Default Value Enable To enable or disable US Postnet scan the appropriate barcode Enable US Postnet Disable US Postnet US Planet Parameter Default Value Enable To enable or disable US Planet scan the appropriate barcode Enable US Planet Disable US Planet ...

Page 260: ... Enable To enable or disable UK Postal scan the appropriate barcode Enable UK Postal Disable UK Postal Transmit UK Postal Check Digit Parameter Default Value Transmit Select whether to transmit UK Postal data with or without the check digit Transmit UK Postal Check Digit Do Not Transmit UK Postal Check Digit ...

Page 261: ...er Default Value Enable To enable or disable Japan Postal scan the appropriate barcode Enable Japan Postal Disable Japan Postal Australian Postal Parameter Default Value Enable To enable or disable Australian Postal scan the appropriate barcode Enable Australian Postal Disable Australian Postal ...

Page 262: ... Imager Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B Dutch Postal Parameter Default Value Enable To enable or disable Dutch Postal scan the appropriate barcode Enable Dutch Postal Disable Dutch Postal ...

Page 263: ...efault Value Transmit Select whether to transmit US Postal data with or without the check digit Transmit US Postal Check Digit Do Not Transmit US Postal Check Digit 4State Postal Parameter Default Value Disable To enable or disable 4State Postal scan the appropriate barcode Enable 4State Postal Disable 4State Postal ...

Page 264: ...follow to enable or disable each variant of GS1 DataBar RSS GS1 DataBar Omnidirectional RSS 14 Parameter Default Value Enable To enable or disable RSS 14 scan the appropriate barcode Enable GS1 DataBar Omnidirectional RSS 14 Disable GS1 DataBar Omnidirectional RSS 14 See Also Convert RSS to UPC EAN GS1 DataBar Limited RSS Limited Parameter Default Value Enable To enable or disable RSS Limited scan...

Page 265: ...mited symbols not decoded as part of a Composite symbol Enable this parameter to strip the leading 010 from GS1 DataBar Omnidirectional RSS 14 and GS1 DataBar Limited RSS Limited symbols encoding a single zero as the first digit and report the barcode as EAN 13 For barcodes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and reports the barcode as UPC A Th...

Page 266: ...sable Scan one of the following barcodes to enable or disable Composite barcodes of type CC C Enable Composite CC C Disable Composite CC C Composite CC A B Parameter Default Value Disable Scan one of the following barcodes to enable or disable Composite barcodes of type CC A B Enable Composite CC A B Disable Composite CC A B ...

Page 267: ...W BLUESCANPG B Bluetooth Ring Scanner Guide Composite TLC 39 Parameter Default Value Disable Scan one of the following barcodes to enable or disable Composite barcodes of type TLC 39 Enable Composite TLC 39 Disable Composite TLC 39 ...

Page 268: ...e options for these symbols UPC Never Linked Transmit UPC barcodes regardless of whether a 2D symbol is detected UPC Always Linked Transmit UPC barcodes and the 2D portion If 2D is not present the UPC barcode does not transmit Autodiscriminate UPC Composites The decoding engine determines if there is a 2D portion then transmits the UPC as well as the 2D portion if present UPC Never Linked UPC Alwa...

Page 269: ...ode 128 Emulation Mode Select whether to enable or disable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes Parameter Default Value Disable Enable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes Disable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes ...

Page 270: ...gies PDF417 Parameter Default Value Enable To enable or disable PDF417 scan the appropriate barcode below Enable PDF417 Disable PDF417 MicroPDF417 Parameter Default Value Disable To enable or disable MicroPDF417 scan the appropriate barcode below Enable MicroPDF417 Disable MicroPDF417 ...

Page 271: ...s if it was encoded in Code 128 symbols Transmit AIM Symbology Identifiers must be enabled for this parameter to work If Code 128 Emulation is enabled these MicroPDF417 symbols are transmitted with one of the following prefixes C1 if the first codeword is 903 907 912 914 915 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 If disabled they are transmitted with one of t...

Page 272: ...e To enable or disable Data Matrix scan the appropriate barcode below Enable Data Matrix Disable Data Matrix Data Matrix Inverse Parameter Default Value Regular Only This parameter controls the setting of the DataMatrix inverse decoder Scan the appropriate barcode below Regular Only Inverse Only Inverse Auto Detect ...

Page 273: ...e Maxicode Parameter Default Value Enable To enable or disable Maxicode scan the appropriate barcode below Enable Maxicode Disable Maxicode QR Code Parameter Default Value Enable To enable or disable QR Code scan the appropriate barcode below Enable QR Code Disable QR Code ...

Page 274: ...t Value Enable To enable or disable MicroQR scan the appropriate barcode below Enable MicroQR Disable MicroQR QR Inverse Parameter Default Value Regular Only This parameter controls the setting of the QR Inverse decoder Scan the appropriate barcode below Regular Only Inverse Only Inverse Auto Detect ...

Page 275: ... Value Enable To enable or disable Aztec scan the appropriate barcode below Enable Aztec Disable Aztec Aztec Inverse Parameter Default Value Regular Only This parameter controls the setting of the Aztec Inverse decoder Scan the appropriate barcode below Regular Only Inverse Only Inverse Auto Detect ...

Page 276: ...fully read twice before being decoded Code Type Code Length Codabar 8 characters or less MSI 4 characters or less D 2 of 5 8 characters or less I 2 of 5 8 characters or less Redundancy Level 2 The following code types must be successfully read twice before being decoded Code Type Code Length All All Redundancy Level 3 Code types other than the following must be successfully read twice before being...

Page 277: ...SE4400 Imager Barcodes 265 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Redundancy Level 1 Redundancy Level 2 Redundancy Level 3 Redundancy Level 4 Cancel ...

Page 278: ...decoding most in spec barcodes Security Level 1 Select this option if misdecodes occur This default setting should eliminate most misdecodes Security Level 2 Select this option if Security level 1 fails to eliminate misdecodes Security Level 3 If Security Level 2 was selected and misdecodes still occur select this security level Be advised selecting this option is an extreme measure against mis de...

Page 279: ...SE4400 Imager Barcodes 267 E SW BLUESCANPG B Bluetooth Ring Scanner Guide Security Level 3 Cancel ...

Page 280: ...e an intercharacter gap that is typically quite small Due to various barcode printing technologies this gap can grow larger than the maximum size allowed preventing the decoder from decoding the symbol If this problem occurs scan the Large Intercharacter Gaps parameter to tolerate these out of specification barcodes Normal Intercharacter Gaps Large Intercharacter Gaps ...

Page 281: ...epresent a numeric keypad with decimal values 0 through 9 Each label can be scanned individually to enter a numeric value Use these numeric value symbols to enter numeric input in the course of performing an imager engine system configuration To correct an error or change a selection scan Cancel then scan a desired barcode 0 1 2 3 4 5 ...

Page 282: ...270 SE4400 Imager Barcodes Bluetooth Ring Scanner Guide E SW BLUESCANPG B 6 7 8 9 Cancel ...

Page 283: ...des As distance decreases the visible scan line also decreases visible scan length 1 8 x distance to label x TAN scan angle 2 The useable scan length is approximately 90 of visible scan line and must fully encompass the barcode label to be successfully decoded On larger symbol densities of 20 mil 40 mil and 55 mil this affects minimum decode distance 5º pitch is used to reduce the inhibiting effec...

Page 284: ... mil 1 50 in 3 81 cm 13 00 in 33 02 cm 2 00 in 5 08 cm 9 50 in 24 13 cm 10 mil 1 50 in 3 81 cm 18 00 in 45 72 cm 1 75 in 4 45 cm 14 00 in 35 56 cm 13 mil 1 50 in 3 81 cm 24 00 in 60 96 cm 1 75 in 4 45 cm 18 00 in 45 72 cm 15 mil 1 50 in 3 81 cm 28 00 in 71 12 cm 1 75 in 4 45 cm 21 00 in 53 34 cm 20 mil 1 75 in 4 45 cm 33 00 in 83 82 cm 27 00 in 68 58 cm 40 mil 36 00 91 44 cm 28 00 in 71 12 cm 55 m...

Page 285: ...ew FOV limited 2 Working range specifications at temperature 23 C pitch 15 roll 0 skew 0 photographic quality ambient light 30 ft c humidity 45 70 RH MS4407 Typical Working Ranges Guaranteed Working Ranges Symbol Density Near Far Near Far 5 0 mil 2 7 in 6 9 cm 5 5 in 14 0 cm 4 0 in 10 2 cm 5 0 in 12 7 cm 6 67 mil 3 0 in 7 62 cm 5 25 in 13 3 cm 4 5 in 11 4 cm 5 0 in 12 7 cm 7 5 mil 2 2 in 5 6 cm 6 ...

Page 286: ...OV limited 2 Working range specifications at temperature 23 C pitch 15 roll 0 skew 0 photographic quality ambient light 30 ft c humidity 45 70 RH MS4407 Typical Working Range Guaranteed Working Range Symbol Density Near Far Near Far 5 0 mil 5 5 in 13 9 cm 7 0 in 17 8 cm N A N A 6 67 mil N A N A N A N A 7 5 mil 3 5 in 8 9 cm 9 0 in 22 9 cm 5 5 in 14 0 cm 7 0 in 17 8 cm 10 mil 5 0 in 12 7 cm 9 0 in ...

Page 287: ...mited 2 Working range specifications at temperature 23 C pitch 15 roll 0 skew 0 photographic quality ambient light 30 ft c humidity 45 70 RH MS4407 Typical Working Ranges Guaranteed Working Ranges Symbol Density Near Far Near Far 5 0 mil 2 7 in 6 9 cm 7 0 in 17 8 cm 4 0 in 10 2 cm 5 0 in 12 7 cm 6 67 mil 3 0 in 7 6 cm 5 25 in 13 3 cm 4 5 in 11 4 cm 5 0 in 12 7 cm 7 5 mil 2 5 in 6 4 cm 8 75 in 22 2...

Page 288: ...n 17 5 cm 7 5 mil Far 4 25 in 10 8 cm 7 125 in 18 1 cm Near 3 25 in 8 3 cm 6 375 in 16 2 cm 10 mil Far 5 75 in 14 6 cm 7 25 in 18 4 cm Near 2 25 in 5 7 cm 7 375 in 18 7 cm 13 mil Far 3 00 in 7 6 cm 8 375 in 21 3 cm Notes 1 Near distances are FOV limited 2 Working range specifications at temperature 23 C pitch 15 roll 0 skew 0 photographic quality humidity 45 70 RH 3 Range measurements are when VCC...

Page 289: ...Device Update Wizard on a PC by doubleclicking the DFUWizardSetup version exe file located in the Install folder 2 Accept the license agreement choose typical installation and then select Finish 3 Insert the battery into the Bluetooth module to be updated or used for the initial installation of the BlueCore Device Update Wizard 4 Insert the update cable into the Bluetooth module to be updated The ...

Page 290: ... or specific location Click Next to continue 10 Browse to the driver location on the installation CD driver or your hard drive if the installation program was downloaded to your hard drive and click Next 11 Click Continue Anyway when the dialog box appears stating the driver has not passed Windows logo testing to verify compatibility 12 Select Finish on the next dialog box ...

Page 291: ...n is Start Control Panel System Hardware tab and click the Device Manager button Shown below is a sample of a Device Manager screen 14 Click the plus sign next to Universal Serial Bus controllers Verify the BTRS Ringscanner in DFU mode is present Close all open windows and return to the PC desktop 15 You are ready to update the Bluetooth Ring Scanner module firmware ...

Page 292: ... to your PC by choosing the Universal Serial Bus USB connection type Click Next to continue 4 Select Download a new version of the firmware saving a copy of the current version first Any previous version will be replaced upgrade action and then click Next 5 Browse to and highlight the latest firmware upgrade file The file has a DFU extension Click Select to continue 6 The upgrade process proceeds ...

Page 293: ...Appendix 281 E SW BLUESCANPG B Bluetooth Ring Scanner Guide 7 Click Finish ...

Page 294: ...Char Keystroke 1000 00h U CTRL 2 1001 0lh A CTRL A 1002 02h B CTRL B 1003 03h C CTRL C 1004 04h D CTRL D 1005 05h E CTRL E 1006 06h F CTRL F 1007 07h G CTRL G 1008 08h H CTRL H 1009 09h I CTRL I 1010 0Ah J CTRL J 1011 0Bh K CTRL K 1012 0Ch L CTRL L 1013 0Dh M CTRL M 1014 0Eh N CTRL N 1015 0Fh O CTRL O 1016 10h P CTRL P 1017 1lh Q CTRL Q 1018 12h R CTRL R 1019 13h S CTRL S 1020 14h T CTRL T 1021 15...

Page 295: ...1035 23h C 1036 24h D 1037 25h E 1038 26h F 1039 27h G 1040 28h H 1041 29h I 1042 2Ah J 1043 2Bh K 1044 2Ch L 1045 2Dh 1046 2Eh 1047 2Fh 1048 30h 0 0 1049 31h 1 1 1050 32h 2 2 1051 33h 3 3 1052 34h 4 4 1053 35h 5 5 1054 36h 6 6 1055 37h 7 7 1056 38h 8 8 1057 39h 9 9 1058 3Ah Z 1059 3Bh F 1060 3Ch G 1061 3Dh H 1062 3Eh I 1063 3Fh J 1064 40h V 1065 41h A A 1066 42h B B 1067 43h C C ...

Page 296: ...h I I 1074 4Ah J J 1075 4Bh K K 1076 4Ch L L 1077 4Dh M M 1078 4Eh N N 1079 4Fh O O 1080 50h P P 1081 51h Q Q 1082 52h R R 1083 53h S S 1084 54h T T 1085 55h U U 1086 56h V V 1087 57h W W 1088 58h X X 1089 59h Y Y 1090 5Ah Z Z 1091 5Bh K 1092 5Ch L 1093 5Dh M 1094 5Eh N 1095 5Fh O 1096 60h W 1097 61h A a 1098 62h B b 1099 63h C c 1100 64h D d 1101 65h E e 1102 66h F f 1103 67h G g 1104 68h H h ...

Page 297: ...Bh K k 1108 6Ch L 1 1109 6Dh M m 1110 6Eh N n 1111 6Fh O o 1112 70h P p 1113 71h Q q 1114 72h R r 1115 73h S s 1116 74h T t 1117 75h U u 1118 76h V v 1119 77h W w 1120 78h X x 1121 79h Y y 1122 7Ah Z z 1123 7Bh P 1124 7Ch Q 1125 7Dh R 1126 7Eh S 1127 7Fh Undefined Beep Related Programming Barcodes for the ring scanner ring imager are not supported by LXE ...

Page 298: ...286 Appendix Bluetooth Ring Scanner Guide E SW BLUESCANPG B ...

Page 299: ...22 SE955 120 D 2 of 5 SE4400 236 SE955 123 I 2 of 5 SE4400 230 SE955 129 MSI SE4400 243 MSI Plessey SE955 133 ASCII 29 GS control character SE955 108 ASCII Character Equivalents 282 Assemble Battery and Ring Scanner 9 Module 9 Assemble components 9 Australian Postal SE4400 249 Autodiscriminate UPC Composites SE4400 256 Autodiscriminate UPC EAN Supplementals SE4400 202 SE955 147 Autoexposure 175 Az...

Page 300: ...nese 2 of 5 SE955 100 Cleaning the Beam Aperture 17 CLSI Editing Codabar SE4400 237 SE955 101 Codabar AIM Code SE4400 188 SE955 82 Any Length SE4400 240 SE955 103 CLSI Editing 101 237 Length Within Range SE4400 240 SE955 103 NOTIS Editing SE4400 238 SE955 101 One Discrete Length SE4400 239 SE955 102 Two Discrete Lengths SE4400 239 SE955 103 Codabar SE 100 237 Code 11 Any Length SE4400 225 SE955 10...

Page 301: ...l 8 Module 6 Rings 7 Wrist Strap 7 Composite CC A B SE4400 167 254 Composite CC C SE4400 166 254 Composite TLC 39 SE4400 167 255 Configuring the Bluetooth module 30 Connect scanner cable 9 Connecting the Ring Device Cable 9 Contacting LXE 27 Convert Code 39 to Code 32 SE955 112 EAN 8 to EAN 13 SE955 141 I 2 of 5 to EAN 13 SE4400 233 SE955 126 UPC E to UPC A SE4400 207 SE955 140 UPC E1 to UPC A SE4...

Page 302: ...E955 137 EAN 13 and I 2 of 5 SE4400 233 SE955 126 EAN 8 SE4400 197 SE955 136 to EAN 13 SE955 141 Zero Extend SE4400 209 SE955 141 147 Encode Char 282 Equivalents ASCII 282 Event Reporting 22 F Finger strap assembly disassembly 17 Firmware update 18 Focus Mode SE4400 177 Format Bookland SE4400 199 Function Code 1 FNC1 SE955 108 G General imager attributes 174 GS1 DataBar RSS AIM Code SE4400 189 GS1...

Page 303: ...14 Length Code 128 SE955 110 Code 39 SE4400 215 SE955 114 Code 93 SE4400 220 SE955 118 Length Within Range Codabar SE4400 240 SE955 103 Code 11 SE4400 225 SE955 105 Code 39 SE4400 216 SE955 115 Code 93 SE4400 222 SE955 120 D 2 of 5 SE4400 236 SE955 123 I 2 of 5 SE4400 230 SE955 128 MSI SE4400 243 MSI Plessey SE955 133 Lengths for I 2 of 5 127 228 Linear barcode scan How to 20 Linear Code Type Secu...

Page 304: ... Length SE4400 242 Two Discrete Lengths SE4400 242 MSI Check Digit 134 SE4400 245 MSI Check Digits and MSI Check Digit Algorithm SE4400 244 MSI Plessey AIM Code SE4400 188 SE955 82 Any Length SE955 133 Check Digit Algorithm SE955 130 Check Digits SE955 131 Length Within Range SE955 133 One Discrete Length SE955 132 SE4400 241 SE955 130 Two Discrete Lengths SE955 132 MSI Plessey Check Digits and MS...

Page 305: ... 60 SE955 88 Scan Data Prefix Suffix SE4400 193 SE955 78 Scan Data Transmission Format SE4400 193 SE955 78 Scan Range 271 Scan Value 282 Scanner Performance LXE Support 23 Scanner Power Mode SE955 87 SE4400 Barcode Types 162 SE4400 Defaults Codabar Lengths SE4400 238 Code 11 Lengths SE4400 223 SE955 Barcode Type Enable Disable 67 SE955 Defaults Aim Duration 74 Codabar Lengths SE955 102 Code 11 Len...

Page 306: ... and Laser On Time SE4400 184 and Laser On Time SE 98 SE4400 184 Trigger Mode SE 98 Trigger module replacement 16 Trioptic Code 39 AIM Code SE4400 187 SE955 81 and Code 39 Full ASCII SE4400 213 SE955 117 SE4400 213 219 SE955 113 117 Troubleshooting Aiming Dot 60 Aiming Modes 60 Ambient lighting and scanner problems 23 Barcode quality 23 Barcode scanning performance 23 Barcode symbology problems 23...

Page 307: ...reamble SE4400 206 SE955 144 SE4400 197 SE955 136 to UPC A SE4400 208 SE955 140 Update module firmware 18 US Planet SE4400 247 US Postal data SE4400 251 US Postnet SE4400 247 User guides on the WWW 27 USS Uniform Symbology Specification SE4400 231 SE955 125 USS 128 SE4400 211 SE955 108 V Verify Check Digit I 2 of 5 SE4400 231 SE955 125 Video Mode 179 W Warnings and Labels Ring Scanner 3 Write Cust...

Page 308: ...296 Index Bluetooth Ring Scanner Guide E SW BLUESCANPG B ...

Reviews: