194
Installation Procedure, LXE Models 6723 Bridge & 6720 AP (RoHS)
NEMA Type 4 Enclosure Reference Guide
E-EQ-NEMARG-F
159128-0001-R Rev. A
Page 4 of 11
6. Apply three (3) Foam Pads, 155145-0001, to each bracket, 160042-001-R as
shown in figure 3.
7. Remove the screw in the upper left corner of the AP Mounting Plate. See
figure 4. Put it aside for later use.
8. Place Bracket 160042-0001-R over both the AP and the Bridge.
9. Secure the brackets with nine (9) 6-32 screws and the one that was removed in
Step 7.
Figure 3
Foam pads
Figure 4
Remove this
screw.