1 7
Protection
Parameter
Value
Note
Grounding
Mains earth, chassis and audio
ground are connected internally.
Output short circuit current
±40A
Output DC voltage
±5V @ <0.1Hz
Over temperature
All heat sinks and mains-trans-
former.
Auto resetting thermal fuse in
mains transformer.
Mains
Parameter
Value
Note
Mains input connector
IEC 320 cold type
Mains lead supplied.
Mains voltage range
100-120V AC, 50–60Hz
115V version
Mains voltage range
200-240V AC, 50-60Hz
230V version
Internal mains fuse
8 Amp
115V version
Internal mains fuse
4 Amp
230V version
Power consumption
1.5 W
STANDBY mode.
Power consumption
35 W
OPERATE mode, no output.
Power consumption
116 W
2*37.5W/4ohms.
Power consumption
820 W
2*300W/4ohms.
Trigger
Parameter
Value
Note
TRIGGER OUT connector
3.5mm (1/8”) mono jack
Case=Gnd, Tip=Input
TRIGGER OUT Voltage
12V DC
Short circuit protected
Mechanical
Parameter
Value
Note
Width
450mm (17.72”)
Depth
355mm
(13.98”)
Including loudspeaker connec-
tors.
Height
100mm (3.94”)
Including feet.
Net weight
13.0Kg (28.66lb.)
Shipping weight
16.0Kg (35.27lb.)
Summary of Contents for SDAI 2175
Page 1: ...Owner s manual SDAI 2175 Semi Digital Amplifier Integrated ...
Page 2: ...2 ...
Page 19: ...19 ...