background image

Reference Manual D VD 5010 Version 1.0

 

 

Page 11  

 

 

Installation 

 

Caution 

The CardModule is shipped in a 

protective anti-static bag. Please take 
suitable precautions to avoid static 

discharge onto any part of the PCB or 

components when handling module or 
serious damage could result. 

 

Each Card Module is supplied with a rear 
connection panel and two mounting screws. 

Please follow the following procedure for 

installation of the card module into the Series 5000 
Card Frame. 

 

a)

 

Select a slot in the card frame where the 
CardModule will be located 

b)

 

Remove the blank connection panel from the 

rear of the rack (if fitted) 

c)

 

Install the rear connection panel using the 

screws supplied. Do not tighten the screws fully 

d)

 

Slide the card module into the card frame and 
carefully check the CardModule easily 

connects to the rear connection plate. The 
card should fit easily and should not require 

excessive force to insert, if you feel any 

resistance, there could be something wrong 
with the rear connection panel location. Do not 

try and force the connection. Remove the rear 

connection panel and check alignment with 
the CardModule. 

e)

 

Insert and remove the CardModule a few times 

to ensure correct alignment and then tighten 
the two screws to secure the rear connection 

plate 

 

 

Summary of Contents for CardModule D VD 5000

Page 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual D VD 5010 Reclocking SDI Distribution Amplifier CardModule Version 1 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Page 5: ...C 47 Part 15 4 Contents 5 Getting Started 7 Packaging 7 Product Description 7 Functional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Alarm LED...

Page 6: ...Reference Manual D VD 5010 Version 1 0 Page 6 This page is intentionally left blank...

Page 7: ...primarily for broadcast and professional applications 8 reclocked outputs are provided with auto detection of standard digital video bit rates 143Mbit s 177Mbit s 270Mbit s 360Mbit s The D VD 5010 is...

Page 8: ...the basic functional diagram for the D VD 5010 CardModule Figure 1 D VD 5010 Functional Diagram Module Layout Figure 2 shows the layout of the D VD 5010 CardModule and the rear connection panel Please...

Page 9: ...Reference Manual D VD 5010 Version 1 0 Page 9 Figure 2 Module Layout Caution Use static precautions when handling the PCB Static discharge could result in serious damage to the module...

Page 10: ...e of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 82...

Page 11: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module...

Page 12: ...indicated via the Alarm LED on the front card edge or via the LYNX control system when using one of the optional controllers and control software Alarm LED Status Indicator The D VD 5010 module has a...

Page 13: ...onal control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is select...

Page 14: ...p nom Return loss 15dB 270 Mbit s Connection BNC Performance Cable Equalization Up to 250m using Belden 8281 270Mbit s Jitter 0 2 UI Status Monitoring LED Signal presence Electrical Specifications Ope...

Page 15: ...20 Rack controller for the R FR 5010 Card Frame R CT 5030 Master controller with TCP IP interface for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination...

Page 16: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Page 17: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 18: ...Reference Manual D VD 5010 Version 1 0 Page 18 Notes...

Reviews: