background image

Reference Manual D VD 5010 Version 1.0

 

 

Page 13  

 

 

Locate Function 

For larger systems which may have multiple cards 
of the same type in a single rack, or multiple rack 

systems on a large central control system we have 

added a useful utility which will help to visually 
locate a suspect module quickly (When used in 

conjunction with the optional control system and 

software) 
 

Once the specific module has been selected on 

the control system there is a locate button on the 
top of the GUI: 

 

 
 

 

 
 

 

 

                       Locate Function in Control System 

 
When Locate is selected the status indicator on the 

GUI and the alarm LED will flash yellow in the 

following continuous sequence.  
 

3 short flashes…. Pause…. 3 short flashes … 

 
Use of the locate function will not interfere with the 

normal operation of the module. 

 

For more details on this feature please check the 

documentation supplied with the controller 

software. 

 

Summary of Contents for CardModule D VD 5000

Page 1: ...Series 5000 LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany www lynx technik com Reference Manual D VD 5010 Reclocking SDI Distribution Amplifier CardModule Version 1 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Page 5: ...C 47 Part 15 4 Contents 5 Getting Started 7 Packaging 7 Product Description 7 Functional Diagram 8 Module Layout 8 Connections 10 Video Connections 10 Installation 11 Settings and Control 12 Alarm LED...

Page 6: ...Reference Manual D VD 5010 Version 1 0 Page 6 This page is intentionally left blank...

Page 7: ...primarily for broadcast and professional applications 8 reclocked outputs are provided with auto detection of standard digital video bit rates 143Mbit s 177Mbit s 270Mbit s 360Mbit s The D VD 5010 is...

Page 8: ...the basic functional diagram for the D VD 5010 CardModule Figure 1 D VD 5010 Functional Diagram Module Layout Figure 2 shows the layout of the D VD 5010 CardModule and the rear connection panel Please...

Page 9: ...Reference Manual D VD 5010 Version 1 0 Page 9 Figure 2 Module Layout Caution Use static precautions when handling the PCB Static discharge could result in serious damage to the module...

Page 10: ...e of high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 82...

Page 11: ...e located b Remove the blank connection panel from the rear of the rack if fitted c Install the rear connection panel using the screws supplied Do not tighten the screws fully d Slide the card module...

Page 12: ...indicated via the Alarm LED on the front card edge or via the LYNX control system when using one of the optional controllers and control software Alarm LED Status Indicator The D VD 5010 module has a...

Page 13: ...onal control system and software Once the specific module has been selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is select...

Page 14: ...p nom Return loss 15dB 270 Mbit s Connection BNC Performance Cable Equalization Up to 250m using Belden 8281 270Mbit s Jitter 0 2 UI Status Monitoring LED Signal presence Electrical Specifications Ope...

Page 15: ...20 Rack controller for the R FR 5010 Card Frame R CT 5030 Master controller with TCP IP interface for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination...

Page 16: ...stributor for assistance We offer a fixed cost service exchange program for defective Series 5000 CardModules out of Warranty Please contact your distributor or check our web site for details on this...

Page 17: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 18: ...Reference Manual D VD 5010 Version 1 0 Page 18 Notes...