background image

 

 
 
 

 

Series 3000 

© LYNX Technik AG 

Sandstraße 7 

64404 Bickenbach 

Germany 

 www.lynx-technik.com

 

Reference Manual 

D AD 3220 B  

Dual Digital Audio Distribution Amplifier 

MiniModules

 

Du
al

 Digi

ta

l Audi

Di

st

ib

utio

n Amp

D AD 3220

AES in 1

AES in 2

OUT 1.1

OUT 2.1

OUT 1.2

OUT 2.2

OUT 1.3

OUT 2.3

OUT 1.4

OUT 2.4

LY
N

X

 Techni

k A
G

made in Germany

www.lynx-technik.com

Version 1.0 

Summary of Contents for D AD 3220 B

Page 1: ...k com Reference Manual D AD 3220 B Dual Digital Audio Distribution Amplifier MiniModules Dual Digital Audio Distibution Amp D AD 3220 AES in 1 AES in 2 OUT 1 1 OUT 2 1 OUT 1 2 OUT 2 2 OUT 1 3 OUT 2 3...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exc...

Page 3: ...arranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Page 4: ...equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause...

Page 5: ...r Connections 11 DC Power Connector 11 Installation 12 Mechanical 12 Stand Alone Operation 12 Multiple Units 13 Electrical Installation 14 Stand Alone Operation 14 Multiple Units 15 Settings and Contr...

Page 6: ...Reference Manual D AD 3220 B Version 1 0 Page 6 This Page is intentionally left blank...

Page 7: ...ES input can have independent sample rates ranging from 32KHz to 108KHz Channel status LED s are provided as well as a front side alarm LED This version of the module features BNC 75 Ohm connections d...

Page 8: ...gh standard 75 Ohm BNC video connections AES3id Module configuration is set via a small dip switch located behind an access hole in the bottom of the module If the module is being used in a stand alon...

Page 9: ...AES in 1 AES in 2 OUT 1 1 OUT 2 1 OUT 1 2 OUT 2 2 OUT 1 3 OUT 2 3 OUT 1 4 OUT 2 4 LYNX Technik AG made in Germany www lynx technik com 1 2 3 4 LED 1 LED 2 DIP Switch ON OFF Bottom LED 2 LED 1 Alarm L...

Page 10: ...ors for AES3 id digital audio Connection is self explanatory We recommend the use of high quality cable suitable for digital applications to reduce the risk of interference or errors due to excessive...

Page 11: ...locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown below 3 4 5 1 2 GND 5V i2C SDA data i2C SCL clock Power Connection Data C...

Page 12: ...R 3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with t...

Page 13: ...Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is...

Page 14: ...he module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections are correct and compatible equipment is feeding receiving the signals from...

Page 15: ...via the integral 4 position dip switch This is located on the bottom of the module and can be accessed through the cutout provided fig 2 1 2 3 4 DIP Switch ON OFF LED 2 LED 1 Channel 1 Status Channel...

Page 16: ...hes may not reflect the actual configuration stored in the module This is because all settings can be changed from the remote control system or via the Service Adapter This overrides the local dip swi...

Page 17: ...ration Local Adjustment Enabled Switch 1 ON Dual 2 x 1 4 mode Switch 2 ON If this is the mode of operation required then no adjustments are necessary Auto Store If no parameters are changed for 10 sec...

Page 18: ...is for AES in 1 and LED 2 is for AES in 2 Note When in 1 8 mode LED2 is always OFF 1 2 3 4 DIP Switch ON OFF LED 2 LED 1 Channel 1 Status Channel 2 Status Front Panel Alarm Indicator There is also a s...

Page 19: ...n selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flas...

Page 20: ...Sample Rate 32kHz to 108kHz independent for each input channel Jitter 0 025 ui Status Monitoring Input present confidence flag AES bi phase coding and parity error Control Remote Control of configurat...

Page 21: ...on any surface R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 3010 R FR 3010 Rack F...

Page 22: ...6 155 002 280 Service If you are experiencing problems or have questions concerning your D AD 3220 B MiniModule please contact your local distributor for assistance We offer a fixed cost service excha...

Page 23: ...acted directly using the information below Address LYNX Technik AG Sandstra e 7 64404 Bickenbach Germany Phone 49 0 6257 938017 Fax 49 0 6257 938025 Website www lynx technik com E Mail info lynx techn...

Page 24: ...Reference Manual D AD 3220 B Version 1 0 Page 24 This Page is intentionally left blank...

Page 25: ...Reference Manual D AD 3220 B Version 1 0 Page 25 Notes...