3.4 Troubleshooting
In the event of incorrect connection or misfunctioning, the amp will activate one or more of its LED to warn about
the problem.
Correct function
: SGNL lights to indicate signal presence.
ICL:
The Intelligent Clip Limiter is operating.
No Signal:
No Input Signal is reaching
the amp.
Overheating:
The amplifier has reached the maximum operational temperature. Most common cause is: the normal
air flow is blocked, accumulated dirt, dust or object leaning against the grill. Check and clean periodically.
PMS:
Several causes can trigger this LED, most common are:
- The amplifier is in power-on sequence, where output is inhibited until the amp circuits are ready to operate.
- The internal temperatures rise to near thermal shutdown point due to unfavourable operating conditions.
- Excessive mains current consumption.