CARE & USE/INSTALLATION
|
45
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135,000
70
123,000
80
115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL
CERAMIC BURNER (Btu)
ROTISSERIE (Btu)
TRIDENT ™(Btu)
TOTAL INPUT
L27R
2 @ 25,000
1 @ 14,000
64,000 Btu/Hr
L27TR(F)
1 @ 25,000
1 @ 14,000
1 @ 21,000
62,000 Btu/Hr
L30R(F)
2 @ 25,000
1 @ 14,000
64,000 Btu/Hr
L30TR(F)
1 @ 25,000
1 @ 14,000
1 @ 21,000
62,000 Btu/Hr
L36R
3 @ 25,000
1 @ 14,000
89,000 Btu/Hr
L36TR(F)
2 @ 25,000
1 @ 14,000
1 @ 21,000
87,000 Btu/Hr
L42R
3 @ 25,000
1 @ 16,000
91,000 Btu/Hr
L42TR(F)
2 @ 25,000
1 @ 16,000
1 @ 21,000
89,000 Btu/Hr
L54TR(F)
3 @ 25,000
2 @ 14,000
1 @ 21,000
126,000 Btu/Hr