Lynx
Model
No.
LHFS
Page
24
P/N
33348
Rev.
A
7/2010
Maintenance and Trouble Shooting
Maintenance
∗
Follow Caution and General Safety rules at all times before / during use.
∗
Before performing ANY service to the heater, shut off the gas supply,
disconnect the regulator
from the LP-Gas Cylinder and remove the battery from the ignitor module.
∗
If any maintenance issues are found place the heater OUT OF SERVICE until it has been
repaired by a certified service person.
Use only manufacturer recommended replacement parts.
Daily Inspections:
1.
Keep the appliance area clean and free from combustible materials, gasoline and other flammable
vapors and liquids.
2.
The visible portion of the Gas Hose must be visually inspected before each use. If there is evidence
of excessive abrasion or wear, or if the hose is damaged the hose assembly must be replaced prior
to the appliance being put into operation.
3.
Keep the ventilation opening(s) of the cylinder enclosure free
and clear from debris and cobwebs.
4.
Visually check the Burner flame pattern during use. A
“
Proper Flame
” should resemble image on right.
5.
If at any time flames extend beyond the emitter surface (see
image to the right below “
Improper Flame
”) or black soot is
found on the inside of the reflector
TURN OFF
the heater
immediately and place
OUT OF SERVICE
until repairs are
made.
6.
Clean the appliance, if necessary, with non-combustible and
non-corrosive cleaning agents. Ensure control compartment
(ignition module), burners & circulating air passageways are
kept clean of dust, insects, cobwebs and other debris.
Annual Inspections:
1.
Inspect and Leak Test entire Gas Hose Assembly for damage,
excessive abrasion , wear and leaks:
a.
Ensure burner is cool to touch and supported while
disassembling.
b.
Disassemble the Burner from the Pole by removing the three (3) screws in the Pole Neck.
c.
Remove the Gas Hose Assembly from the Pole to inspect and Leak Test
the entire hose and
all connections
. Repair / replace as required and reassemble as described in Outdoor Patio
Heater Assembly, Steps 6 & 11 of the Installation Instructions.
2.
Check condition of the Burner, especially the integrity of the flame screen.
3.
Inspect condition of spark and sense electrode. Check for cracks in ceramic insulators or excessive
corrosion.
4.
Inspect condition of high tension lead to spark rod.