Lynx NGT-9000s
Installation Manual
[J1 connector] (Continued)
PIN 48
Signal Name:
TX_429A (ARINC 429_IN A)
Signal Function:
ARINC 429 Output for CDTI display
Electrical Characteristics:
High Speed ARINC 429 (100 kbps)
L-3 Sky-497 STIF format
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.8
PIN 49
Signal Name:
TX_429B (ARINC 429_IN B)
Signal Function:
ARINC 429 Output for CDTI display
Electrical Characteristics:
High Speed ARINC 429 (100 kbps)
L-3 Sky-497 STIF format
Connection:
24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.8
PIN 50
Signal Name:
RS422_RX2A
Signal Function:
RS-422 FIS-B Input
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
PIN 51
Signal Name:
RS422_RX2B
Signal Function:
RS-422 FIS-B Input
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
PIN 52
Signal Name:
RS422_TX2A
Signal Function:
RS-422 FIS-B Output
Electrical Characteristics:
Data bits 8, Parity none, Stop bit 1, Start bit 1, Data
format is ASCII, Flow control is none.
Baud Rate: (configuration option) 38400, 57600, or
115200. Depending on the equipment manufacturer
Connection:
Optional. 24 AWG twisted shielded pair wire
Comments:
See paragraph A.2.6
0040-17001-01
Appendix A
Page A-19
Revision A
January 15, 2015