Lynx NGT-9000s
Installation Manual
Appendix B
Environmental Qualification Form
B.1 INTRODUCTION
This appendix includes the environmental qualifications form required for the Lynx NGT-9000s Multilink
Surveillance System, Detachable Configuration Module, NY156, and NY164 Directional Antenna.
B.2 NGT-9000 ENVIRONMENTAL QUALIFICATION FORM
PRODUCT DESCRIPTION:
Multilink Surveillance System
TYPE DESIGNATION:
NGT-9000D Release 1
MODEL:
NGT-9000+, NGT-9000D
HARDWARE PART NO.:
9029000-20000
SOFTWARE PART NO:
9020010-001
MANUFACTURER:
Aviation Communication and Surveillance Systems
ADDRESS:
ACSS 19810 N. 7th Avenue Phoenix, AZ 85027-4741
PRODUCT DESCRIPTION::
Configuration Module
PART NUMBERS:
9230-17003-01
MANUFACTURER:
Aviation Communication and Surveillance Systems
ADDRESS:
ACSS 19810 N. 7th Avenue Phoenix, AZ 85027-4741
DESCRIPTION
SECT.
NO.
CAT.
DESCRIPTION
Temper
at
ur
e and A
lti
tude
Low Temperature
4.5.1
4.5.2
F1
-20° C Operating
-40° C Short Time Operating.
-55° C Ground Survival
High Temperature
4.5.3
4.5.4
+55° C Operating
+70° C Short Time Operating
+85° C Ground Survival
In-Flight Loss of
Cooling
4.5.5
Not Applicable, Not Tested.
External Cooling Not Required
Altitude
4.6.1
Tested to 55,000 ft Maximum Operating Altitude
Decompression
4.6.2
A1
8,000 ft to 55,000 ft.
Overpressure
4.6.3
-15,000 ft.
Temperature Variation
5.3.1
B
5° C/min
Non-controlled temperature, Equipment mounted
internal in aircraft
Humidity
6.3.1
A
Standard Humidity Environment
0040-17001-01
Appendix B
Page B-1
Revision A
January 15, 2015