Lynx NGT-9000s
Installation Manual
DESCRIPTION
SECT.
NO.
CAT.
DESCRIPTION
Emission of RF Energy
21
M
Interference free operation
Lightning Induced
Transient Susceptibility
22
A3J3L3
A3: Pin Injection Waveform Tests:
Waveform 3 600 VOC/24 ISC
Waveform 4 300 VOC/60 ISC
J3: Cable Bundle Single Stroke:
Waveform 3 600 VT/120IL
Waveform 3 600 VT/120IL
J3: Cable Bundle Multiple Stroke:
Waveform 1
First Stroke 300 VL/300 IT
Sub Strokes 150 VL/150IT
Waveform 3
First Stroke 600 VL/120 IL
Sub Strokes 300 VL/60IL
L3: Cable Bundle Multiple Burst:
Waveform 3: 360 VT/6IL
Lightning Direct Effects
23
X
Not Applicable, Not Tested.
Icing
24
X
Not Applicable, Not Tested.
Electro Static Discharge
25
A
15 kv/330
Ω
/150pf
Fire, Flammability
26
X
Other Tests
None
0040-17001-01
Appendix B
Page B-3
Revision A
January 15, 2015