Gas
conversion
kits
are
available
from
Lynx
grills
to
allow
the
SmartGrill
by
Lynx™
to
operate
on
either
natural
gas
or
liquid
propane
gas.
The
kit,
available
from
Lynx
Grills
or
your
dealer,
must
be
installed
by
a
quali
fi
ed
technician
All
Installa on
and
all
installa on
parts
must
conform
to
local
codes
with
the
Na onal
Electrical
Code
ANSI
Z223.1/NFPA
70
latest
edi on
and
the
Na onal
fuel
Gas
Code
ANSI
Z223.1/NFPA
54
in
the
U.S.
and
CGA
‐
B
149.1/.2
in
Canada.
Canadian
installa ons
must
conform
to
CGA
‐
B
149.1/.2
natural
gas/propane
installa on
code.
(Canada)
The
ra ng
plate
lists
serial
numbers,
model
numbers
and
gas
type
and
is
located
in
one
or
more
of
the
fol
‐
lowing
places:
A ached
to
the
underside
of
the
drip
tray
On
the
back
of
the
Care
&
Use
manual
On
the
PC
case
The SmartGrill by Lynx
™
is factory set to use either
liquid propane or natural gas. It is critical that the gas
you use matches that for which the grill was set up.
You can verify this by checking the rating plate.
Fuel
WC
Max
Inlet
WC
Min
Un
‐
der
Full
Load
Nat
Gas
7
in
4
in
LP
14
in
11
in
Ensure
that
the
gas
supplied
meets
with
the
minimum
pressure
requirements.
Do
not
operate
the
grill
with
any
gas
other
than
that
for
which
the
grill
has
been
set
Water
Column
Requirements
Table:
Both
the
regulator
and
the
manifold
ori
fi
ces
have
been
tuned
for
the
type
of
gas
speci
fi
ed
on
the
ra ng
plate.
Lynx
recommends
that
only
quali
fi
ed
professionals
perform
the
required
plumbing
on
this
product.
To
ensure
sa sfactory
performance,
the
gas
supply
line
must
be
sized
to
accommodate
the
total
BTU
requirements
of
all
the
gas
‐
fi
red
equipment
that
will
be
connected
to
that
line.
In
no
case
should
pipe
less
than
¾”
inside
diameter
or
1”
outside
diameter
ever
be
used
to
connect
this
product.
Calculate
the
total
BTU
output
of
all
equipment
and
refer
to
“INDEX:
“Gas
Supply
Line
Runs:
for
allowable
run
distances
for
¾”
pipe.
Failure
to
meet
these
minimum
requirements
may
reduce
performance
of
the
grill
and
other
appliances
running
on
that
supply
line.
Always
keep
supply
line
runs
as
short
as
possible.
(See
INDEX:
“BTU
Output”
for
speci
fi
c
model
outputs)
A
gas
shut
‐
o
ff
valve
must
be
installed
in
an
easily
accessible
loca on
by
a
quali
fi
ed
plumber.
Keep
threading
compound
o
ff
the
fi
rst
two
pipe
threads
to
avoid
having
any
small
pieces
of
compound
break
loose
and
clog
a
burner
valve
or
ori
fi
ce.
Do
not
use
threading
compound
on
any
fl
are
fi
ngs.
For
built
‐
in
installa ons,
it
is
recommended
that
any
fl
exible
pipe
used
be
kept
as
short
as
possible.
(See
INDEX:
“Gas
Connec ons”
for
typical
permanent
hook
up.)
GAS
CONVERSION
KITS
NEVER
CONNECT
A
GAS
LINE
DIRECTLY
TO
THE
SMARTGRILL
BY
LYNX™.
A
PRESSURE
REGULATOR
MUST
BE
INSTALLED
ON
ALL
GAS
EQUIPMENT.
ALL
LOCAL
CODES
REQURE
IT
AND
LYNX
GRILLS
SUPPLIES
THE
CORRECT
REGULATOR
FOR
USE
WITH
YOU
GRILL.
REMOVING
OR
FAILING
TO
INSTALL
THE
PRESSURE
REGULATOR
CAN
RESULT
IN
FIRE
AND
SERIOUS
PERSONAL
INJURY
AND
WILL
VOID
THE
WARRANTY.
WARNING
NATURAL
GAS
Keep
last
two
threads
clean
For
freestanding
units
using
natural
gas,
lynx
strongly
recommends
using
a
quick
disconnect
kit.
This
Quick
Disconnect
Kit
(part
#LQD)
is
available
from
Lynx
or
your
dealer.
GAS
CONNECTIONS
Summary of Contents for SMART30
Page 1: ...SMARTGRILL USER MANUAL...
Page 2: ...SmartGrill by LynxTM...
Page 35: ...WIRING DIAGRAMS 30 SmartGrill Electrical Diagram...
Page 36: ...WIRING DIAGRAMS 36 and 42 SmartGrill Electrical Diagram...
Page 37: ...EXPLODED PARTS DIAGRAMS...
Page 38: ...EXPLODED PARTS DIAGRAMS...
Page 39: ...EXPLODED PARTS LIST...
Page 40: ...EXPLODED PARTS LIST AND DIAGRAMS...
Page 41: ...EXPLODED PARTS LIST AND DIAGRAMS...
Page 42: ...EXPLODED PARTS LIST AND DIAGRAMS...
Page 47: ......