background image

 

This is a complete set of protections that 

monitors the main amp parameters (load 

status, signal input, temperature, current, 

etc.) in order to draw from the power sup-

ply only the precise amount of current 

required to maintain safe operation during 

hazardous or extreme working conditions.  

 

This system controls the amount of power 

that the amp delivers under three basic 

circumstances: 

 

1.- The power-on sequence, where output 

is inhibited until the amp circuits are ready 

to operate. This routine is repeated at 

every restart, not just when the power 

switch is activated. 

 

2.- When internal temperatures rise to 

near thermal shutdown point due to 

unfavourable operating conditions. Here 

the system takes control, restricting cur-

rent so as to maintain operational continu-

ity at the precise power level which the 

amp is capable of withstanding at that par-

ticular moment. 

 

3.- Excessive mains current consumption. 

This event only occurs either under labora-

tory conditions (long term sinusoidal signal 

testing with dummy loads) or, for example, 

in field applications in conditions of pro-

longed acoustic howl-round. Here PMS 

takes control to avoid any damage to the 

speakers and to prevent the mains break-

er from tripping or the fuses blowing. 

 

 

 

The RAM Audio ICL2 is an anticlip system  

to avoid speaker failure and provide more 

acceptable sound quality even when clip-

ping occurs. With the ICL2 system you 

don't lose the music “punch” but the 

speakers are kept under control. 

 

 

 

 

SOA Sentry protection effectively limiting 

the power that the amp could deliver into 

an incorrect load or to a direct short-cir-

cuit. This avoids power transistor failure. 

 

 

 

 

Faulty Channel Management system to 

avoid entire device shutdown.

FCM

™ 

Faulty Channel Management

PMS

™ 

-

 

Power Management System

SSP

™ 

SOA Sentry Protection

ICL2

™ 

-

 

Intelligent Clip Limiter

 

Vollständiges Set von Schutzfunktionen 

das die wichtigsten Endstufenparameter 

überwacht (Auslastung, Signaleingang, 

Temperatur und Stomstärke) um vom 

Netzanschluss nur die Menge Strom zu 

beziehen, die für den betriebssicheren 

Arbeitsablauf notwendig ist 

 

Dieses System reguliert die von der 

Endstufe abgegebenen Leistung in 3 

Fällen: 

 

1.- Anschaltevorgang: Der Ausgang wird 

gehemmt bis die Endstufe voll funktions-

bereit ist. Dieser Vorgang wiederholt sich 

bei jedem Neustart, nicht nur wenn der 

Leistungsschalter aktiviert wurde. 

 

2.- Wenn die Innentemperatur aufgrund 

ungünstiger Arbeitsbedingungen nahe des 

Grenzwertes steigt, bei dem die automa-

tische Ausschaltefunktion aktiviert würde, 

um eine Überhitzung des Systems zu ver-

meiden. In diesem Fall übernimmt das 

System die Kontrolle und reduziert die 

Stromzufuhr auf ein Niveau, dass die 

Endstufe in dieser Situation aushalten 

kann. 

 

3.- Überhöhter Stromverbrauch: Diese 

Situation stellt sich ausschließlich unter 

Laborbedingungen ein (in sinusförmigen 

Langzeitsignaltests mit Dummylasten oder 

in langanhaltenden akustischen Feedback 

Bedingungen. Hier greift das PMS System 

ein um eine Schädigung der Lautsprecher 

zu vermeiden und um zu verhindern dass 

der Hauptunterbrecher ausgelöst wird oder 

die elektrischen Sicherungen durchbren-

nen. 

 

 

 

Das RAM Audio ICL2 ist ein Anticlipsystem 

das das Versagen der Lautsprecher ver-

meidet und auch wenn Clipping auftritt 

noch eine bessere Tonqualität gewährleis-

tet. Mit dem ICL2 System verlieren Sie 

den “Punch” nicht, und der Lautsprecher 

arbeitet kontrolliert. 

 

 

 

SOA Die Leistung, die die Endstufe an 

inkorrekte Lasten oder an einen 

Kurzschluss abgeben könnte wird wirksam 

limitiert. Dies verhindert die Zerstörung der 

Leistungstransistoren. 

 

 

 

Faulty Channel Management system to 

avoid entire device shutdown. 

FCM

™ 

Faulty Channel Management

SSP

™ 

SOA Sentry Protection

PMS

™ 

-

 

Power Management System

ICL

™ 

-

 

Intelligent Clip Limiter

Protection Systems

 

Este es un completo set de protecciones 

que monitoriza los parámetros principales 

del amplificador (estado de la carga, señal 

de entrada, temperatura, corriente, etc.) 

para así sacar de la fuente de alimenta-

ción solo la cantidad de corriente requeri-

da para mantener una operación segura 

durante condiciones extremas de trabajo. 

Este sistema controla la cantidad de 

potencia que el amplificador entrega bajo 

tres circunstancias básicas: 

1.- La secuencia de encendido, donde la 

salida es inhibida hasta que los circuitos 

del amplificador están preparados para 

operar. 

2.- Cuando la temperatura interna llega 

casi al punto de bloqueo térmico debido a 

condiciones de operación desfavorables. 

Aquí el sistema toma el control restringien-

do la corriente para mantener la continui-

dad operacional al nivel de potencia preci-

so en el que el amplificador es capaz de 

resistir este particular momento.  

3.- Consumo de corriente excesivo. Este 

caso solo ocurre o en condiciones de 

laboratorio (test con señal sinoidal durante 

largo tiempo con cargas ficticias) o, por 

ejemplo, en aplicaciones de campo en 

condiciones de re-alimentación acústica. 

Aquí el PMS toma el control para evitar 

cualquier daño en los altavoces y prevenir 

que el magnetotérmico salte o los fusibles 

se fundan .   

 

 

 

El ICL2 es un sistema anticlip que evita 

daño en el altavoz y provee de una cali-

dad de sonido más aceptable incluso 

cuando el clip está ocurriendo. Con el sis-

tema ICL2 no puerdes el “punch” de la 

música pero el altavoz es mantenido bajo 

control. 

 

 

 

El sistema SOA Sentry Protection limita de 

forma efectiva la potencia que el amplifica-

dor puede entregar frente a una carga 

incorrecta o a un corto-circuito. Este evita 

fallos en los transistores de potencia. 

 

 

 

 

El sistema Faulty Channel Management 

evita un bloqueo total del amplificador. 

FCM

™ 

Faulty Channel Management

PMS

™ 

-

 

Sistema manejo de potencia

ICL2

™ 

-

 

Limitador de clip inteligente 

SSP

™ 

- Protección SOA Sentry

Sistemas de 

protección

10

Schutzschaltungs- 

systeme

Summary of Contents for Subamp SBA-12000

Page 1: ...OPERATION MANUAL BEDIENUNGSANLEITUNG MANUAL DE EMPLEO Lynx Pro Audio Spain www lynxproaudio com info lynxproaudio com Professional Power Amplifiers Subamp Series SBA 12000 SBA 18000 ...

Page 2: ...rsonal Es handelt sich um ein Gerät der Klasse I IMPORTANT Clean the front panel filters regularly Extract the filters removing the front panel grid unscrewing the screews pla ced at the sides of the grid Clean the filters using water and detergent Place the grid filter introducing first the internal side and screwing the screws 1 VORSICHT GEFAHR EINES ELEKTRISCHEN SCHLAGES NICHT ÖFFNEN PRECAUCIÓN...

Page 3: ...eisungen 1 1 Einleitung 1 2 Allgemeine Eigenschaften 2 Lokalisierung der Funktionen 2 1 Frontplatte 2 2 Rückplatte 3 Anschluss und Inbetriebnahme 3 1 Anschlüsse 3 1 1 Dual Kanalmodus 3 1 2 Link Kanalmodus 3 2 Konfiguration 3 3 Problemlösung 4 Technische Spezifikationen 4 1 Schutzschaltungssysteme 4 2 Technische Daten INHALTSVERZEICHNIS INDEX 0 Advertencias de Precaución 1 Información general 1 1 I...

Page 4: ...s canales preparados para soportar las extremadamente exigentes aplicaciones del mundo del touring Para esto los amplificadores de la serie SBA han sido diseñados con una sobredimensionada fuente de alimentación regulada de alto rendimiento con Corrección de Factor de Potencia PFC para entregar toda su potencia independientemente de cómo esté la red eléctrica Esto junto a una etapa de potencia de ...

Page 5: ...hanzeige des einge henden Signals ICL Die LED zeigt an dass der Intelligent Cliplimiter arbeitet siehe Seite 13 Beleuchteter Hauptstromschalter Position I Schaltet die Endstufe ein Position O Schaltet die Endstufe aus 3 2 2 1 Frontplatte 1 1 Controls Where and What Ver Figura Atenuadores de control de nivel permite modificar el nivel de la señal de entrada independiente mente para cada canal PMS i...

Page 6: ...o connect the amplifier to the mains network The color code is Blue Neutral Brown Live single phase Yellow green Protective Earth Gain Selection Minidips Gain Selection Minidips 1 and 2 Three positions for 32 38 or 44dB Gain Default setting 32dB Minidips de selección de modo with minidips 3 and 4 you chose operation mode Link or Dual 3 2 2 Rückplatte 2 1 2 4 5 Lokalisierung der Funktionen 5 Contro...

Page 7: ...sse 2 Signal 3 Masse ACHTUNG Wenn Sie ein asymetris ches Signal anschließen und Pin 3 nicht an Masse anschließen erzeugt dies einen Verlust von 6dB 1 4 der Leistung der Endstufe am Ausgangssignal Die Endstufe verfügt über eine parallele XLR Buchse für die Zusammenschaltung mehrerer Endstufen 3 1 Anschlüsse Installation and Operation Para proceder al conexionado de la uni dad sitúe siempre el inter...

Page 8: ...mbra Conecte los altavoces a los Speakon de cada canal respetando polaridad Utilice el control de nivel de cada canal para controlar independiente mente los niveles de salida Los LEDs de señalización indicaran la situación independientemente de cada canal Ver figura Coloque los minidips traseros en posi ción Link 3 y 4 arriba Opere como modo Dual con la señal de entrada linkada a otro canal adya c...

Page 9: ...3 4 Dual Channel 2 Ch models 2 Ch models 8 Link Inputs ...

Page 10: ...rd so lange gehemmt bis die Enstufe voll funk tionsbereit ist Die Innentemperatur steigt aufgrund ungünstiger Arbeitsbedingungen nahe des Grenzwertes bei dem die automa tische Ausschaltefunktion aktiviert wird um eine Überhitzung des Systems zu vermeiden Überhöhter Netzstromverbrauch 3 3 Problemlösung Installation and Operation Si se produce alguna anomalía en la Instalación o durante el funcionam...

Page 11: ...schließlich unter Laborbedingungen ein in sinusförmigen Langzeitsignaltests mit Dummylasten oder in langanhaltenden akustischen Feedback Bedingungen Hier greift das PMS System ein um eine Schädigung der Lautsprecher zu vermeiden und um zu verhindern dass der Hauptunterbrecher ausgelöst wird oder die elektrischen Sicherungen durchbren nen Das RAM Audio ICL2 ist ein Anticlipsystem das das Versagen d...

Page 12: ...0 2 Crosstalk B d 0 8 z H k 0 2 z H 0 2 Voltage Gain 32 38 44 dB Sensitivity Rated Power 32 38 44dB Gain 3 9 1 9 1 V 4 7 2 4 1 2 V Signal to Noise Ratio B d 8 1 1 B d 6 1 1 z H k 0 2 z H 0 2 Required AC Mains Operating Voltage 50Hz 60Hz 90V 265V AC 170V 265V AC A 5 0 A 5 0 V 0 3 2 g n i l d I n O r e w o P A 6 1 A 4 1 V 0 3 2 m h O 4 r e w o P d e t a R 8 1 limited by PMS for fuse saver protection...

Reviews: