background image

 

 

GENERAL PRINCIPLES OF DEVICE SAFETY  
 
Prior to device usage initiation, refer to the following 
manual  and act according the guidelines contained 
therein. The manufacturer shall not be held accountable 
for any damages caused by improper usage of the device 
or its improper handling 

 

1.1 

.OPERATING PRINCIPLES 
 

1. The sublimator is a device for the evaporation of oxalic 
acid. It is powered by 12V DC. 
2. Before starting the treatments, you must absolutely put 
on the protective clothes (protective glasses, rubber 
gloves, gas mask) 

 

 
1.2. ELECTRICAL SAFETY 

 
1. If the power cord is damaged and needs to be replaced, 
this operation should be performed at the guarantor's or 
by a specialized repair facility or by a qualified person. 
Do not use the device if the connecting cable is damaged! 
2. It is forbidden to pull the connection cable. 
The cable should be kept away from heat sources, sharp 
edges and its good condition. 
 

 

 
 
 
 
 
 
 
 
1.3.OPERATING SAFETY

 

 
The following equipment is not intended to be used by 
persons with limited physical, sensory or mental capabili-
ties (including children) or persons inexperienced or unfa-
miliar with that type of equip-ment unless the usage oc-
curs under supervision or in line with the equipment oper-
ating manual provided by safety supervising persons. 
Make sure that chil-dren do not play with the device  
 

2. 

  If the device cable gets damaged, the rep airs mustbe 

performed solely by a specialized repair centreor by a 
qualified person in order to avoid any threat 
3. It is forbidden to perform any maintenance works when 
the device is in  
4.WARNING: 
-the device heats up to high temperatures! 
- oxalic acid is corrosive 
-acid vapors are irritating to the skin, eyes and respiratory 
system 
- wear protective clothing against burns (gloves, protective 
suit) 
-use a mask protecting the respiratory tract and goggles 
- oxalic acid should be stored in a sealed, labeled container 

 

 

 
 
 
 
 

 
 

2. Characteristics of the 
device 

Oxalic acid sublimator is used to control warroa destructor 
in bee colonies. For optimal treatment, the temperature 

outside the hive should be around 10 ° C.

 

The sublimator is ready to use right after taking it out of 
the suitcase, just connect the device to a 12V power 
source. The device has a profiled inside cover (2) of the 
heating head, into which we pour about 2g. oxalic acid. 
The set includes two lids (2) and a measuring cup. 
 

 

USING THE DEVICE 
- remove the cover (2) from the heating head (3) 
- connect the sublimator to the battery and wait for 
the green and red diodes on the controller to light up 
permanently 
- we close the sublimator with a lid with oxalic acid 

Reviews: