background image

The following manual encompasses 

the device bearing the following 

code: 

W3012 

Manual 

1. General safety operational

principles for the device

1.1. Operational principles
1.2. Electrical safety
1.3. Operational safety

2. Manual

2.1. Operational principles

3. Device characteristics

3.1. Device description
3.2. Controller description
   3.2.1. Controller set-ups 
   3.2.2. Starting work with 
controller 
   3.2.3. Error report for controller 
   3.2.4. Controller technical 
parameters 
   3.2.5.Technical data

 

4. Device storage
5. Maintenance and cleaning
6. Recycling
7. Guarantee

1.

GENERAL SAFETY

Summary of Contents for W3012

Page 1: ...orstwo Pszczelarskie Tomasz Łysoń Spółka z o o Spółka Komandytowa 34 125 Sułkowice ul Racławicka 162 Polska www lyson com pl email lyson lyson com pl tel 33 875 99 40 33 870 64 02 Siedziba Firmy Klecza Dolna 148 34 124 Klecza Górna ...

Page 2: ...al safety 1 3 Operational safety 2 Manual 2 1 Operational principles 3 Device characteristics 3 1 Device description 3 2 Controller description 3 2 1 Controller set ups 3 2 2 Starting work with controller 3 2 3 Error report for controller 3 2 4 Controller technical parameters 3 2 5 Technical data 4 Device storage 5 Maintenance and cleaning 6 Recycling 7 Guarantee 1 GENERAL SAFETY ...

Page 3: ...3 OPERATIONAL SAFETY The following equipment is not intended to be used by persons with limited physical sensory or mental capabilities including children or persons inexperienced or unfamiliar with that type of equipment unless the usage occurs under supervision or in line with the equipment operating manual provided by safety supervising persons Make sure that children do not play with the devic...

Page 4: ...V 3 Main switch 0 1 4 5A fuse holder 5 Stainless steel body 6 Stainless steel shelf perforated for de crystalization of jars with honey 3 2 Controller description HC 01 temperature regulator has been mounted in the device Heating Controller c 4 5 6 3 1 2 3 2 1 Controller s set up 1 Prior to plugging in the device to the mains one must make sure that the controller is switched off Switch 0 1 on the...

Page 5: ...ecified in oC 4 button value decreasing Working mode pressing the button will decrease the preset temperature value During preliminary heating the option to change the setting for preset temperature is blocked Working time setting mode pressing the button will decrease the time after which the thermostat will get switched off Display brightness setting mode pressing the button will decrease the br...

Page 6: ...by means of and buttons the user has a possibility to define the preset temperature that shall be maintained during preliminary heating Exit from the mode and setting conformation occurs when the ON OFF button is pressed shortly Longer pressing and holding of the button and its subsequent releasing will activate the preset temperature limit setting mode signalled by L t h notice In this mode by me...

Page 7: ... Ambient temperature of the regulator under storage 0oC 60oC Air humidity for the regulator under operation Max 65 at 25 o C 3 2 5 Technical data power supply 230V power 300W temperature range 30 55º C load capacity approx 150 kg the body made of sandwich panel reinforced by stainless steel plate with removable stainless steel drawer and stainless steel shelf for jars body with the dimensions 650x...

Page 8: ...ust be contacted 6 RECYCLING Worn out product must be removed as waste only within selective waste collection organised by the Network of Communal Electric and Electronic Waste Collecting Points A customer is entitled to return the used equipment to the electrical equipment distributor network at least free of charge and directly if the device to be returned is of proper type and serves the same p...