background image

 

 

Description of the incubator

:

 

 

A

- distilled water tank - 4L.

 

B-

water level indicator

 

C-

air holes

 

D-

controller

 

E-

incubator chamber

 

F-

transparent door to control the raising process

 

G-

incubator door

 

                                                 

Figure 2 

 

 
 

A         B                C         D        E 

 
Description of the controller: 
 
A-

main switch 0-1

 

B-

controlling panel

 

C-

power supply cable

 

D-

5A fuse holder

 

E-

Bluetooth communication outlet

 

 

2.2  Handing the controller 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

       

  ŁYSOŃ   IC-0x    0.1

  . . . . . . .

2

3

4

5

1

 

 
 
 

ELEMENT 

DESCRIPTION 

 display 

 

After 

activation

 

 

displays 

sequentially:  manufacturer’s  name, 

device type and software version 

1.  Main  screen

 

  basic  screen 

selected  by  default  once  the  device 
has 

been 

activated. 

Screen 

description below. 

2.  The  screen  to  set  the  setpoint 
temperature 

  the  displays  shows 

the  temperature  measured  (upper 
line)  and  the  setpoint  temperature 
(lower line). 

3.  The  screen  to  set  the  setpoint 
humidity

 

  the  display  shows  the 

humidity measured (upper line) and 
the setpoint humidity (lower line). 

4.  The  screen  for  operating 
statistics

 

 the displays     shows the 

minimal  and  maximum  values    of 
temperature and humidity registered 
(since the control supply activation). 
Reset  of  the  values  registered  shall 

occur  after  pressing  the  „plus”  or 
„minus” buttons  

 

5.  Service  screen  for  TH  sensor 
temperature  readouts  calibration 

 the display shows the temperature 

measured    including  the  calibration 
(upper  line)  and  the  calibration 
value (lower line) 

6.  Service  screen  for  humidity 
readouts calibration

  

 the display 

shows  the  humidity  measured 
including  the  calibration  (upper 
line)  and  the  calibration  value 
(lower line) 

7.  Service  screen  for  temperature 
regulator  tuning

 

  the  display 

shows  the  value  of  Kp  parameter 

 

tuning of the  temperature  regulator. 
In 

case 

when 

the 

setpoint 

temperature  has  not  been  achieved 
or  when  reaching  the  temperature 
lasts  too  long,  the  value  of  the 
parameter  must  be  increased.  
Respectively,  when  there  are 

Summary of Contents for W5014

Page 1: ...si biorstwo Pszczelarskie Tomasz yso Sp ka z o o Sp ka Komandytowa 34 125 Su kowice ul Rac awicka 162 Polska www lyson com pl email lyson lyson com pl tel 33 875 99 40 33 870 64 02Siedziba Firmy Klecz...

Page 2: ...ety principles for device operation 1 1 Operational principles 1 2 Electrical safety 1 3 Operational safety 2 Characteristics of the device 2 1 Device description 2 2 Controller handling 2 3 Error cod...

Page 3: ...idden to pull the power supply cable The power supply cable must be kept away from any heat sources sharp edges and its proper state must be secured 1 3 Operational safety 1 The following equipment is...

Page 4: ...humidity the display shows the humidity measured upper line and the setpoint humidity lower line 4 The screen for operating statistics the displays shows the minimal and maximum values of temperature...

Page 5: ...for min and max values Additionally in the deactivated state it is possible to switch on and off the cabin lighting switch between the screens reset the operating statistics and to modify the paramet...

Page 6: ...ocked ON OFF button 300 Damaged sensor of temperature measurement for TH composite sensor 301 Temperature indication of TH composite sensor outsider the permissible range 302 Temperature regulation er...

Page 7: ...ectrical equipment distributor network at least free of charge and directly if the device to be returned is of proper type and serves the same purpose as the newly purchased device 6 Guarantee Product...

Reviews: