background image

3

0°C

°C

°C

-10°C

SAFETY TIPS

The device emits invisible (IR) and visible laser radiations. The visible 

laser beams can be activated during the installation process to adjust  

the position of the detection field.  

Do not stare directly into the visible red beams.  

The visible laser beams are inactive during normal functioning. 

The door control unit and 

the door cover profile 

must be correctly earthed.

Test the good functioning 

of the installation before 

leaving the premises.

Only trained and qualified

personnel may install and

adjust the sensor.

• 

The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of 
the sensor.  

• 

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in 
compliance with applicable national and international regulations and standards on door safety. 

• 

The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.

• 

The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.

Avoid extreme

vibrations.

Do not cover the front 

screens. Remove the 

laser window protection 

before use.

Avoid moving objects 

and light sources in

the detection field.

Avoid the presence

of smoke and fog in

the detection field.

Avoid condensation.

When needed, wipe the 

laser window only with 

a soft, clean and damp 

microfibre cloth

Avoid exposure to 

sudden and extreme

temperature changes.

Avoid direct exposure

to high pressure

cleaning.

Do not use aggressive

products to clean 

the front screen.

Keep the sensor

permanently powered

in environments where

the temperature can

drop below -10

°

C

.

CAUTION!

 

Use of controls, adjustments or performance of procedures other than those specified herein may result in 

hazardous radiation exposure.

INSTALLATION AND MAINTENANCE

SYMBOLS

Caution!

Laser radiation

Remote control 

sequence

Possible

remote control

adjustments

Factory values

Attention

Note

Summary of Contents for FLATSCAN REV PZ

Page 1: ...U B T Z E R T I F I Z I E R U N G N A C H EN 16005 E N A B L E S A C C O R D A N C E W I T H PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING User s Guide for software version SW 0200 and high...

Page 2: ...djustment screw 3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION The LZR FLATSCAN REV PZ is a safety sensor for automatic revolvi...

Page 3: ...fety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted...

Page 4: ...low sticker faces towards the out side of the door Make sure the front side of the sensor where you ll find the yellow sticker faces towards the rotation axis of the door After changing a DIP switch...

Page 5: ...visible spots Try to position the red spots as close to the door as possible Just make sure the door is not detected If 2 m mounting height d 4cm If 3 m mounting height d 5cm If 4 m mounting height d...

Page 6: ...red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED f...

Page 7: ...case of false detection button and are not recommended When DIP2 is OFF changes automatically to 10 cm Note that the uncovered zone reduces the detection field not only at the bottom but also on the...

Page 8: ...s code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS DETECTION FIELD ADJUSTMENT Launch detection field Teach in refer to the teach in process on page 6 Launch en...

Page 9: ...output redirection and configuration enable disable the LED when there is a detection disable the output and LED for during 15 minutes and can be useful during an installation a mechanical teach in o...

Page 10: ...sensor Replace sensor The sensor does not react when powered Test error Check voltage between red and blue wires The service mode is activated Exit the service mode It is not possible to adjust a sett...

Page 11: ...d 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and...

Page 12: ...r Testbody CB EN CC DIN 300 mm x 100 mm x 65 mm foot shaped Optical characteristics IEC EN 60825 1 Wavelength 905 nm output power 0 1 mW CLASS 1 Wavelength 635 nm output power 1 mW CLASS 2 visible spo...