TROUBLESHOOTING

The ORANGE LED is on 
permanently.

The sensor encounters a 
memory problem.

Send the sensor back for a technical check-up.

The ORANGE LED flashes 
quickly.

DIP-switch setting awaiting 
confirmation.

Corfirm the DIP-switch setting: long push on the 
push button.

The ORANGE LED flashes
1 x every 3 seconds.

The sensor signals an 
internal fault.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED flashes
2 x every 3 seconds.

Power supply is out of limit.

1

Check power supply (tension, capacity).

2

Reduce the cable length or change cable.

The ORANGE LED flashes 
3 x every 3 seconds.

The sensor signals an 
internal fault.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED flashes 
4 x every 3 seconds.

Something close to the sensor 

is masking part of the 

detection field.

1

Make sure the laser window is not scratched. 
If it is, replace sensor.

2

Remove all masking elements (insects, spider web, 
flexible tube, laser window protection).

3

Verify if the laser window is dirty and clean it with 
compressed air. Then wipe it carefully with a damp 
and clean microfibre cloth if necessary
(attention: the surface of the laser window is delicate).

The sensor does not see its 

background.

Switch DIP 3 to off (deactivates background).

The ORANGE LED flashes 
5 x every 3 seconds.

Teach-in error.

1

Check whether all teach-in requirements are 
fulfilled and launch a new teach-in.

2

Adjust the tilt angle of the laser curtain and launch 
a new teach-in.

3

Make sure there are no objects on the ground 
during teach-in and launch a new teach-in.

The ORANGE LED flashes 
6 x every 3 seconds.

Installation height higher

than limitation.

Press the push button during at least 5 seconds to 
confirm the installation height of sensor is higher 
than 4m.

Summary of Contents for FLATSCAN SL

Page 1: ...FLATSCAN SLsurface PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING EN User s Guide for product version 0100 and higher See product label for serial number COMPACT LASER SCANNER FOR SLIDING D...

Page 2: ...tion 7 DIP switch 8 Power cable DESCRIPTION Caution Laser radiation Remote control sequence Possible remote control adjustments Factory values Attention Note The LZR FLATSCAN SLsurface is a multi func...

Page 3: ...t a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The sensor manufacturer cannot be he...

Page 4: ...DIP switch the orange LED flashes A LONG push on the push button confirms the settings active high JFS active low normal ON OFF Place the template onto the suitable position Drill 2 screw holes and 1...

Page 5: ...E SPOTS ADJUSTMENTS SETTINGS Quickly press the push button twice to activate the visible spots they will help you position the curtain Quickly double click to activate or deactivate the visible laser...

Page 6: ...he left right limit of the detection field The LED flashes red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to de...

Page 7: ...NFIGURATION NO normally open NC normally closed NO POWER NO DETECTION DETECTION In order to change these settings by remote control adjust DIP switch 4 to ON The LED turns green if there is a detectio...

Page 8: ...e sensor can be adjusted with the remote control If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore t...

Page 9: ...ield of 1cm TEACH IN turn on off the visible spots factory reset of all values factory reset of all values except field dimensions output redirection and configuration disable the output and LED for 1...

Page 10: ...Launch a new safety field teach in Unwanted detections due to environment or external conditions 1 Make sure the laser curtain at the correct position 2 Verify if the laser window is dirty and clean i...

Page 11: ...ose to the sensor is masking part of the detection field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser wind...

Page 12: ...y free Max switching voltage 42V AC 60V DC Max switching current 100 mA 1 Relay free of potential change over contact Max contact voltage 60V AC 125V DC Max contact current 1 0A resistive Max switchin...