14. For Each Relay: Connect one end of a #18 AWG red wire to the relay,
Pin 86. Cut the lead to length, and connect the other end to the 1 amp fuse
holder supplied. Use crimp on connectors supplied. Connect the other
side of the 1 amp fuse holder to the A+ battery source or a vehicle A+
fuse block. Use a #18 AWG red wire and a ring lug supplied, if needed
(refer to Figure 11-9).
15. Check dual control operation, using the operator’s manual (available at
www.macom-wireless.com) as a test guide. In ProGrammer, make sure
the “DUAL CONTROL SPEAKER” is programmed
ACTIVE HIGH
.
Set Output to “