background image

 

12 

5.  OPTIONS AND ACCESSORIES 

Table 5-1:  EDACS D3100 RF Modem Options and Accessories 

DESCRIPTION 

PART NUMBER 

D3100 Test Box  

TS103114V1 

Roof Top Antenna 

AV102800V1 

Yagi, 8dBd, Fixed-station Antenna  

AN103358V1 

Control Unit, Orion, Scan, D2CP5L  

KRY 1011632/12 

Data/Programming C-U Adapter Cable  

CA103067V1 

Mounting Bracket Kit 

19B802672P1 

5.1 

ADAPTER CABLE, CA103067V1 

This accessory, part of the D3100 package, provides connection from the 
D3100 Data Connector to a data connection, DB9-RS232 format, and to an 
optional Orion Control Unit, should this be required. It also provides the 
means of initiating “programming mode” and programming the D3100 from a 
PC from its “

COM

” (serial) port. A drawing and wiring schematic of this 

cable is shown in Figure 5-1. 

Summary of Contents for P5100 Series

Page 1: ...60 Herndon Parkway Model EDACS D3100 800 MHz Mobile Data Modem Suite 1400 FCC ID OWDTR 0037 E Herndon VA 20170 Standards FCC Part 90 IC RSS 119 http www rheintech com Report 2004178 36 of 44 APPENDIX...

Page 2: ...Installation and Operator s Manual MM21134 December 04 EDACS D3100 RF Modem...

Page 3: ...ly by an authorized service technician or facility designated by the supplier Any repairs alterations or substitution of recommended parts made by the user to this equipment not approved by the manufa...

Page 4: ...PLIANCE WITH RF EXPOSURE STANDARDS 5 1 2 1 Mobile Antennas 6 1 2 2 Approved Accessories 6 1 2 3 Contact Information 7 2 SAFETY INFORMATION 8 2 1 COMMON HAZARDS 8 3 INTRODUCTION 9 4 DESCRIPTION 10 4 1...

Page 5: ...more users over a distance It uses RF energy or radio waves to send and receive calls RF energy is one form of electromagnetic energy Other forms include but are not limited to electric power sunligh...

Page 6: ...al includes information and operating instructions required to control your RF exposure and to satisfy compliance requirements 1 2 COMPLIANCE WITH RF EXPOSURE STANDARDS Your M A COM Inc EDACS D3100 RF...

Page 7: ...of These mobile antenna installation guidelines are limited to metal body motor vehicles or vehicles with appropriate ground planes The antenna installation should additionally be in accordance with t...

Page 8: ...duct manuals M A COM s Products and Services Catalog or contact M A COM at 1 800 368 3277 1 2 3 Contact Information For additional information on exposure requirements or other information contact M A...

Page 9: ...transmitting If the vehicle contains such equipment consult the dealer for the make of the vehicle and enlist his aid in determining if such electronic circuits perform normally when the radio is tra...

Page 10: ...00 Data RF Modem The EDACS D3100 Data Modem is a data only mobile or fixed station radio used in the Enhanced Digital Access Communications System EDACS trunking environment systems Table 2 1 EDACS D3...

Page 11: ...named Site containing an EDACS Control Channel 806 075 TX 851 075 RX and an EDACS Working Channel 820 975 TX 865 975 RX The second system is named 851 and is a conventional system for use in parametri...

Page 12: ...NMENTS DB 25 Socket Pin Pin Function 1 NC 2 GND 3 IGN A Not Used 4 NC 5 RQST 6 Audio OUT 7 NC 8 RS485 9 NC 10 NC 11 CTS 12 XDATAIN 13 EXT_MIC_L GND 14 NC 15 NC 16 NC 17 NC 18 FPROG Connect to A for Pr...

Page 13: ...C U Adapter Cable CA103067V1 Mounting Bracket Kit 19B802672P1 5 1 ADAPTER CABLE CA103067V1 This accessory part of the D3100 package provides connection from the D3100 Data Connector to a data connecti...

Page 14: ...Figure 5 1 Adapter Cable CA103067V1 13...

Page 15: ...ATA CABLE D3100 UNIT Figure 6 1 D3100 Unit 6 2 PLAN THE INSTALLATION Before starting plan the modem s installation carefully so that it will be Functional Neat Protected from water damage Easy to serv...

Page 16: ...owing the included instructions in a manner that prohibits or precludes the presence of anyone within the prescribed MPE Radius when the transmitter is on see Table 1 1 Connect the antenna to the D310...

Page 17: ...6 4 D3100 DIMENSIONS 14 144 176 158 50 51 D3100 MECHANICAL VIEWS DIMENSIONS IN MILLIMETERS 31 5 M4 4 Holes 16...

Page 18: ...g the warranty period only for the Equipment covered under Paragraph B 3 and B 4 To be eligible for no charge labor service must be performed at a M A COM factory by an Authorized Service Center ASC o...

Page 19: ...NOTES 18...

Page 20: ...NOTES 19...

Page 21: ...NOTES 20...

Page 22: ...21...

Reviews: