3.4.4
Connect Grounding Cables to Equipment Racks
Attach a ground cable to each rack.
1.
Run #6 Green grounding cable (stranded copper) from each rack ground directly to
the single-point ground bar in each enclosure.
CAUTION
All bends in the grounding cables must be < 70-degrees.
All bends in the grounding cables must have minimum bend radius of 8 inches.
See the M/A-COM Quality Standards Manual (GQM0221) for more information.
2.
At a single point cabinet ground, use a two-hole lug to attach the ground cable. Route
the cables as specified by the installation procedure, using existing cable trays and
overhead ladders, routing cables under raised floors, and so on (see Figure 3-20:
Single Point Ground That is Found on Each Rack and Figure 3-21: Ground Bar).
Figure 3-20: Single Point Ground That is Found on Each Rack
Figure 3-21: Ground Bar