MM102225V1, Rev. B
45
STEPS ACTION
MISCELLANEOUS
8.
Select the
RF GEN
screen and place
the cursor on the
Amplitude
field.
9.
Configure test as follows:
•
Verify HP 8920 RF IN/OUT
port is connected to the antenna
port of the TTA Controller.
•
Disconnect the TX Q cable from
the DCX under test.
•
Connect a Test Cable between
the TX Q port under test and the
Audio In Hi port of the HP
8920.
10.
Adjust the volume control on the HP
8920 until the 1kHz test tone is
audible.
11.
On the RF GENERATOR screen,
reduce the Amplitude of the generated
signal until the indicated value for
SINAD stabilizes at a nominal value
of 12dB.
12.
Record the amplitude on worksheet
and record the results on the data
sheet
7
.
-122 dBm
13.
Repeat for all other DCX’s.
7
Refer to APPENDIX L - RECORDED DATA SHEET.
Summary of Contents for P5100 Series
Page 2: ...Installation Manual MM102225V1 Rev B Jul 05 Base Station Tower Site ...
Page 70: ...MM102225V1 Rev B 69 This page intentionally left blank ...
Page 72: ...MM102225V1 Rev B 71 This page intentionally left blank ...
Page 74: ...MM102225V1 Rev B 73 This page intentionally left blank ...
Page 76: ...MM102225V1 Rev B 75 This page intentionally left blank ...
Page 82: ...MM102225V1 Rev B 81 PARAMETER VALUE EXPLANATION password cisco login end buck40sas ...
Page 92: ...MM102225V1 Rev B 91 This page intentionally left blank ...
Page 94: ...MM102225V1 Rev B 93 This page intentionally left blank ...
Page 96: ...MM102225V1 Rev B 95 This page intentionally left blank ...
Page 99: ...MM102225V1 Rev B 98 This page intentionally left blank ...